Function: 1 (2 Position Single), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: T (NPTF)
Function: 1 (2 Position Single), Body Option: 20 (Body Ported/Individual Pilot EXH), Pilot: Internal Pilot, Voltage: 1 (100VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: T (NPTF)
Function: 1 (2 Position Single), Body Option: 30 (Body Ported/Common Pilot EXH), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: T (NPTF)
Function: 1 (2 Position Single), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Size: 01 (Base Mounted w/Sub-plate 1/8 Side Piping), Thread: T (NPTF)
Function: 1 (2 Position Single), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Port Size: 01 (Base Mounted w/Sub-plate 1/8 Side Piping), Thread: T (NPTF)
Function: 2 (2 Position Double), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 1 (100VAC 50/60HZ), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: C (Locking Lever Style), Port Size: 01 (Base Mounted w/Sub-plate 1/8 Side Piping), Thread: T (NPTF)
Function: 1 (2 Position Single), Body Option: 10 (Base Mounted Non Plug-in), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Size: 01 (Base Mounted w/Sub-plate 1/8 Side Piping), Thread: T (NPTF)
Model: 31, Orifice: 2 (2.2mm), Style: 4 (COM, Single Unit), Option: C37, Seals: NBR, Class B, Suffix: Standard, Port Size: 01 (1/8), Thread: T (NPTF), Voltage: 5 (24VDC), Electrical Entry: T (with Conduit Terminal), Surge Suppressor: S (w/Surge Voltage Suppressor), Rectifier: None (for DC or AC Class H Coil), Bracket: B (Bracket)
Body Size: 20, Thread: Rc, Port: 01 (1/8), Option: G (Round Pressure Gauge w/Limit Indicator), Attachment: T (T Spacer), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard
Body Size: 20, Thread: Rc, Port: 01 (1/8), Option: G (Round Pressure Gauge w/Limit Indicator), Attachment: T (T Spacer), Semi-Standard 1: C (Bowl Guard), Semi-Standard 2: R (Flow Direction: Right->Left)
Model: 31, Orifice: 3 (3mm), Style: 0 (N.C., Single Unit), Option: C37, Seals: NBR, Class B, Suffix: Standard, Port Size: 01 (1/8), Thread: T (NPTF), Voltage: 5 (24VDC), Electrical Entry: T (with Conduit Terminal), Surge Suppressor: Z (w/Light and Surge Voltage Suppressor), Rectifier: None (for DC or AC Class H Coil), Bracket: B (Bracket)
Type of Actuation: 1 (2 Position Single), Manifold Type: 20 (Body Ported Plug-in Integrated), Pilot: Internal Pilot, Specifications: T (Power Saver), Voltage: 5 (24VDC), Electrical Entry: M (M Plug Connector w/Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 01 (Body Ported 1/8), Thread: T (NPTF
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Piping Specification: 01 (R 1/8), Connector Type: S (M12 Connector Type), Bracket: None, Operation Manual: T (w/o Operation Manual, Calibration Certificate)
Type of Actuation: 1 (2 Position Single), Manifold Type: 20 (Body Ported Plug-in Integrated), Pilot: Internal Pilot, Specifications: T (Power Saver), Voltage: 5 (24VDC), Electrical Entry: MO (M Plug w/o Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 01 (Body Ported 1/8), Thread: T (NPTF)
E N T S Communication Cable/Connector EtherNet/IP, PROFINET, EtherCAT, Ethernet POWERLINK p. 222 CC-Link p. 223 DeviceNet p. 224 PROFIBUS DP p. 225 Communication Cable p. 226 Field-wireable Communication Connector p. 228 Terminating Resistor p. 228 Fieldbus Related Accessories M8/M12 Connector PCA/EX9/EX500 Series Power Supply Cable/Connector EX600 Series p. 229 EX500 Series p. 231
3 @0 q MSQA (High precision type) Component Parts Description Material Description Material Deep groove ball bearing Needle bearing Deep groove ball bearing No. q w e r t y u No.
Port size AS-D U01 Uni 1/8 U02 Uni 1/4 U03 Uni 3/8 U04 Uni 1/2 AS-T ASP Needle Valve/Flow Rate Characteristics ASN AS2201FSl-U02, AS2211FSl-U02 AS2201FSl-U01, AS2211FSl-U01 300 600 AQ Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 500 ASV 06, 07, 08, 09, 10 08, 09, 10, 11 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 03, 04 06, 07 200 400 AK 01, 23 300 VCHC 03, 04 100 200 ASR ASQ 01, 23
T-slot A dimension T-slotBdimension Work piece mounting reference plane 6.5 27.5 T-slot B Cross Section C-C (mm) D 4 4 4 4 6 E 6 6 8 8 8 F 107 112 122 132 112 G 55 65 75 85 65 I 1 1 1 1 2 J 65 75 65 70 75 K 2 2 3 3 3 L 6 6 6 6 8 N 55 65 75 85 65 P 2 2 2 2 3 U 52 47 47 47 47 Model Refer to page 301 for mounting.