Choice of output types: PNP, NPN How to Order D-M9PJ J M9 N L D Output specifications Lead wire length Symbol Specication L Between the sensor and amplier: 3 m, Amplier section: 3 m Symbol Specication N NPN output P PNP output Z Between the sensor and amplier: 5 m, Amplier section: 3 m D-M9NJ Dimensions [mm] Auto Switch Specications Indicator light D-M9NJ, D-M9PJ (With indicator light) Auto

Applicable load Type 2-wire 3-wire Solid state auto switch Auto switch model D-M9B(V) D-M9N(V) Load voltage 24 VDC (10 to 28 VDC) 28 VDC or less 5 to 40 mA 40 mA or less Load current range Indicator light Yes Yes 24 VDC relay, PLC PLC: Programmable Logic Controller Refer to page 946 for the applicable auto switches list.

Setting: Operate the NFC-B preferentially using the protocol used. Select the icon. (Windows7 is used in this Operation Manual) (2) Double-click the [NFC port/PaSoRi] icon on the control panel to display the setting window. Select [NFC-B] only for [Detectable cards].

(See page 15, Table 8.) < Applicable Auto switches > Solid state auto switch D-M9N(V)-900M9P(V)-900M9B(V)-900 D-M9NW(V)-900M9PW(V)-900M9BW(V)-900 Reed auto switch D-A90-900 Fig 4. How to Mount and Move the Auto Switch Fig 4.

OFF SUP 1MC 5Ry SGDE servomotor Motor 1MC 1 SGDE servo pack R U V 2 1MC M T 3 W 1CN 4 150 1 2 3 4 5 6 PULS PULS SIGN SIGN CLR CLR Be sure to ground.

Setting: Operate the NFC-B preferentially using the protocol used. Select the icon. (Windows7 is used in this Operation Manual) (2) Double-click the [NFC port/PaSoRi] icon on the control panel to display the setting window. Select [NFC-B] only for [Detectable cards].

Green NS LED is flashing Red PWR(V) LED is On Red MS LED is flashing Red NS LED is flashing Red ST(M) LED is On Red PWR LED is On Green MS LED is On Green NS LED is On Green LEDs are On Red MS LED is On Red NS LED is On LED display The power supply for control and input is Off, or IP address is not set.

Mark A Mark B Joint bracket Bracket for joining to adjacent units. 9 The unit is in normal operation. Green LEDs are ON. 10 Unit connector (Plug) Connector for signals and power supplies to adjacent units. 11 Connector (BUS IN) Connector for fieldbus inputs. A component failure inside the SI unit. Red ST(M) LED is ON. Mark C on the unit Seal cap (2 pcs.) Fitted to unused connectors.

PWR(V) 11 Connect the M12 connector cable. The M12 SPEEDCON connector connection method is explained below. (1)Align mark B on the metal bracket of the cable connector (plug/socket) with mark A. 7 10 8 SF Displays the system status. 1 9 BF Displays the communication status. (2)Align with mark C on the unit and insert the connector vertically.

Red ST(M) LED is flashing Red PWR(V) LED is On Red ST(M) LED is On Green MS LED is On Red PWR LED is On Green LEDs are On Red MS LED is On LED display LED display Off Off URL http://www.smcworld.com PWR(V) Display ST(M) PWR MS NS Displays the network status. for 2 hours each in direction X, Y and Z respectively (De-energized) Displays the module status.

Red ST(M) LED is flashing Red PWR(V) LED is On Red BF LED is flashing Red ST(M) LED is On Red PWR LED is On Green LEDs are On 24 VDC Class2, 2 A Output Either of the following conditions: The cable between the master and SI unit is not connected. The SI unit cannot recognize the communication speed. The maser or the SI unit has broken.

Red ST(M) LED is flashing Green LRUN LED is On Red PWR(V) LED is On Red ST(M) LED is On Red LERR LED is On Red PWR LED is On Green LEDs are On Holds the output. Output is Off. (Default setting) LED display LED display Off Off Content URL http://www.smcworld.com PWR(V) Display ST(M) LRUN LERR Displays the error status.

50/60 Hz 24 V 15 to 10% of rated voltage Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Coil rated voltage Terminal type VT Coil insulation type Class B or equivalent (130C) (3) Shock/Vibration resistance (m/s2) 150/50 (4) VP Note 1) If it is low temperature, dry

Flame Resistant (Equivalent to UL-94 Standard V-0) FR Double Layer Polyurethane Tubing TRBU Series RoHS Model 20 m roll 100 m reel TRBU1208 TRBU1065 TRBU0805 TRBU0604 Model Inner tubing O.D. (mm) 12 10 8 6 Inner tubing I.D.

Nil M5 x 0.8 Rc1/8 Rc1/8 Rc1/8 Rc1/4 TN NPT1/8 NPT1/8 NPT1/8 NPT1/4 TF G1/8 G1/8 G1/8 G1/4 12-CY3B15 12-CY3B20 12-CY3B25 12-CY3B32 12-CY3B40 d b C H B H 4 8 8 10 d M10 x 1.0 M20 x 1.5 M26 x 1.5 M32 x 2.0 B 14 26 32 41 C 16.2 30 37 47.3 Part number SNJ-016B SN-020B SN-032B SN-040B Applicable bore size (mm) 15 20 25, 32 40 161 Specific Product Precautions Be sure to read before handling.

Fittings & Tubing Air Cylinders Rotary Actuators V D C D C E F H A + Stroke B + Stroke GB GA T X PP (Rc, NPT, G): Relief port 2 x P (Rc, NPT, G) Port for extension Port for retraction When the cylinder is extended KA: T-slot for hexagon bolt 4 x M K KB KC 6-K (6 positions) 10 10 M12 x 1.75 M10 x 1.5 M8 x 1.25 M Bore size Standard stroke (mm) GB D A 170 140 10 10 38 38 36.5 E B F KC 11 11

When actually mounting an auto switch, adjust the position after confirming the operating state of the auto switch. 95 Guide table10-MGF Dimensions 10-MGF40/63/100 4-N V D C D C E F H A + Stroke B + Stroke GB GA T X PP (Rc, NPT, G): Relief port 2-P(Rc, NPT, G) Port for extension Port for retraction When the cylinder is extended KA: T-slot for hexagon bolt 4-M K KB KC 6-K (6 positions) 9 9

Fittings & Tubing Air Cylinders Rotary Actuators How to Order 11 Vacuum suction type Clean series 11 M D H R 3 10 R M9B S 22 M D H R 3 10 R M9B S Copper, fluorine and silicone-free + Low particle generation Number of auto switches 2 pcs. 1 pc.