Signal name 1 24 V 1 24 V (Control and input) (Control and input) 2 24 V (Output) 2 24 V (Output) 3 0 V (Control and input) 3 0 V (Control and input) 4 0 V (Output) 4 0 V (Output) 5 Not used (4) EX600-ED5-# PWR IN: M12 4-pin Plug A-coded PWR OUT: M12 5-pin Socket A-coded Configuration Pin No. Signal name Configuration Pin No.
EXW1 EXW1 Up to 100 m V.1.0/V.2.0 Available*1 EXW1 EXW1+EX600 *2 V.1.0 NA EXW1 EX600 Up to 10 m V.1.0 NA EX600 EXW1 Up to 10 m V.1.0 NA Available*3 EX600 EXW1+EX600 Up to 10 m V.1.0 NA Available*3 EX600 EX600 Up to 10 m V.1.0 NA Available *1: Available in protocol V.2.0. *2: Up to 100 m between an EXW1 series Base and Remote, and up to 10 m between an EXW1 series Base and an EX600-W series
Cylinder Bore Sizes (in inches) Valve Type Cv Type* 34 1 118 112 2 214 212 3 314 4 6 Micro-Line 0.11 SA F S S LTV 0.18 SA,DA F F F F M M M M S S Nova 1.00 SA,DA F F F F F F F M M Duramatic 0.18 SA,DA F F F F M M M M S S Duramatic 0.63 SA,DA F F F F F M M M M Capsula 0.75 SA,DA F F F F F F M M M Capsula 3.17 SA,DA F F F FT-1, FC-1 0.13 SA F F M S 4B-1, 4W-1 0.48 SA,DA F F F F M M M S FC51,
Cylinder Bore Sizes (in inches) Valve Type Cv Type* 34 1 118 112 2 214 212 3 314 4 6 Micro-Line 0.11 SA F S S LTV 0.18 SA,DA F F F F M M M M S S Nova 1.00 SA,DA F F F F F F F M M Duramatic 0.18 SA,DA F F F F M M M M S S Duramatic 0.63 SA,DA F F F F F M M M M Capsula 0.75 SA,DA F F F F F F M M M Capsula 3.17 SA,DA F F F FT-1, FC-1 0.13 SA F F M S 4B-1, 4W-1 0.48 SA,DA F F F F M M M S FC51,
6) B L F D Action S T Single acting/Spring return Single acting/Spring extend Standard CJ2 L S 16 45 R CDJ2 L S 16 45 C73 With auto switch R Number of switches With auto switch 2 1 n S n Built-in magnet Auto switch Port location on head cover Refer to the table below for selecting applicable auto switches.
Description 2 1 24 V (for control/input) 1 24 V (for output) 2 24 V (for output) 2 0 V (for output) 3 0 V (for control/input) 3 24 V (for control/input) 4 0 V (for output) 4 0 V (for control/input) 3 (86.6) 4 1 73.6 56.6 Power supply connector PWR OUT: M12 5-pin socket, A-coded Configuration EX600-ED4 (Pin arrangement 1) EX600-ED5 (Pin arrangement 2) Pin no. Description Pin no.
Example using a 20[mm] Lead Actuator with target travel speed of 500[mm/sec] Rotations per second Travel distance per second Travel distance per rotation Rotation Speed (rpm) = {Speed (mm/s) Lead (mm) }60 (S) = {500 (mm/s) 20 (mm) }60 (s) =1500 (rpm) The rotation speed must be a value between 0 and the allowable actuator speed. The actuator will not operate if set to 0.
(full span/full scale) This means "full span" or "full scale", and indicates varied analogue output range at rated value.For example, when analogue output is 1 to 5 V, F.S.=5[V] 1[V]=4[V]. (Reference: 1%F.S. = 4[V] 1% = 0.04[V]) I Instantaneous flow The flow passing per unit of time. If it is 10 L/min, there is a flow of 10 L passing through the device in 1 minute.
For example, when analogue output is 1 to 5 V, F.S. = 5[V] 1[V] = 4[V], (ref. 1%F.S. = 4[V] x 1% = 0.04[V]) The maximum measuring range or change in analogue output over the maximum measurement range. F.S. (Full span, Full scale) H Hysteresis The difference between ON and OFF points used to prevent chattering. Hysteresis can be effective in avoiding the effects of pulsation.
For example, when analogue output is 1 to 5 V, F.S. = 5[V] 1[V] = 4[V], (ref. 1%F.S. = 4[V] x 1% = 0.04[V]) The maximum measuring range or change in analogue output over the maximum measurement range. F.S. (Full span, Full scale) H Hysteresis The difference between ON and OFF points used to prevent chattering. Hysteresis can be effective in avoiding the effects of pulsation.
Point for measure Point for measure Offset voltage (V) Discharge Offset voltage(V) Discharge time (s) time (s) ment ment (1) 1.3 0.20 (1) 0.0 0.19 (2) 2.5 0.34 (2) 0.6 0.40 Notes: When additional air flow pressure is set to 0.2MPa and supply pressure to the dust collector to 0.3MPa.
(See Notes shown below) Continuous operation of the additional air flow Pulse operation of the additional air flow(50ms) Point for measure Point for measure Offset voltage (V) Discharge Offset voltage(V) Discharge time (s) time (s) ment ment (1) 1.9 0.20 (1) 0.6 0.20 (2) 1.3 0.22 (2) 2.5 0.20 (3) 0.6 0.21 (3) 1.3 0.20 (4) 1.9 0.35 (4) 1.3 0.36 (5) 1.9 0.41 (5) 1.9 0.37 (6) 3.1 0.40 (6) 3.1
fluid discharge temperature 0C to 100C: 0 to 10.0 V 2 CH1 circulating fluid electrical conductivity 0.1 to 50.0 S/cm: 0.02 to 10.0 V Analog (2) Analog output signal 2 Output 2 CH2 circulating fluid discharge temperature 0C to 100C: 0 to 10.0 V 1 CH2 circulating fluid electrical conductivity 0.1 to 50.0 S/cm: 0.02 to 10.0 V 1 By default. 2 For option D1 CH1 Electric conductivity control,
Confirm that the surface temperature of the filter or the parts for operation (V-band, element, etc.) are 40C or less, to prevent a burn from occurring. Warning Operation 1. Never loosen the V-band under pressurized conditions. 59
1% F.S. or lessMaximum load impedance: 300 (Power supply voltage 12 V)600 (Power supply voltage 24 V)Minimum load impedance: 50 Non-voltage input (Reed or Solid state), Low level: 0.4 V or less, 5 ms or longer input3 1/2-digit, 7-segment, 2-color LCD (Red/Green)?2% F.S. ?1 digit (Ambient temperature of 77 ?5F)Lights up when output is turned ON.
1% F.S. or lessMaximum load impedance: 300 (Power supply voltage 12 V)600 (Power supply voltage 24 V)Minimum load impedance: 50 Non-voltage input (Reed or Solid state), Low level: 0.4 V or less, 5 ms or longer input3 1/2-digit, 7-segment, 2-color LCD (Red/Green)?2% F.S. ?1 digit (Ambient temperature of 77 ?5F)Lights up when output is turned ON.
IDX-OM-X011-A PRODUCT NAME Refrigerated Air Dryer MODEL / Series IDF190D-3-C,M,R IDF190D-9-V-C,M IDF240D-3-C,M,R IDF240D-9-V-C,M 2 4 0 This manual is intended to explain the installation and operation of the product.
Signal name 1 24 V 1 24 V (Control and input) (Control and input) 2 24 V (Output) 2 24 V (Output) 3 0 V (Control and input) 3 0 V (Control and input) 4 0 V (Output) 4 0 V (Output) 5 Not used (4) EX600-ED5-# PWR IN: M12 4-pin Plug A-coded PWR OUT: M12 5-pin Socket A-coded Configuration Pin No. Signal name Configuration Pin No.
The unnecessary output should remain unconnected. -27 NPN open collector 2 outputs Max. 30 V, 80 mA, Residual voltage 1 V or less -43 NPN open collector 1 output + PNP open collector 1 output Max. 30 V (NPN), 80 mA, Residual voltage 1 V or less A Pressure set value of switch output for NPN and PNP is common. -65 PNP open collector 1 output Max. 80 mA -67 PNP open collector 2 outputs Max.
6 Single acting, spring return Piston seal CQ2B12-S-PS Rod seal NBR 12 16 20 25 32 40 50 CQ2B12-S-PS CQ2B16-S-PS CQ2B20-S-PS CQ2B25-S-PS CQ2B32-S-PS CQ2B40-S-PS CQ2B50-S-PS CQ2B16-S-PS Gasket CQ2B20-S-PS CQ2B25-S-PS CQ2B32-S-PS CQ2B40-S-PS CQ2B50-S-PS Left no. !4. Seal kit includes !4. Order the seal kit, based on each bore size.