Dimensions XMH series / Angled Valve C D L1 L2 A Fn Fc C (Fc) (CF Flange) (KF Flange) H J H B G A Unit:mm Table 5 Model A B C D Fn Fc G H J P.C.D L1 L2 XMH-16 40 100.5 38 1 30 34 17 35 18 P.C.D 27 6x4.4 XMH-25 50 114 48 1 40 26 41 21.5 XMH-40 65 162.5 66 2 55 70 41 57 30 P.C.D 58.7 6x6.6 XMH-50 70 179.5 79 2 75 52 70 35 XYH series / Straight Valve D G C C B H Fn J (KF Flange) 45 Unit: mm
Symbol Output pres-sure display Accuracy 13% (full span) Minimum unit MPa: 0.01, kgf/cm2: 0.01, bar: 0.01, PSI: 0.1 Note 3) kPa: 'l Ambient and fluid temperature 0 to 50'C (with no condensation) Enclosure lP65 eouivalent Weight tw20 3509 tw30 645o Note 1) 2 wire type 4 to 20mA is not available.
Refer to pages 16-143 to 16-14-4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to pages 16-1-11 to 16-1-13 for Precautions on every series. C (COM) A (N.O.) Color of lead wire Black Symbol Contact C Common B (N.C.) A White Normally Open B Red Normally Closed Mounting & Wiring ZSE ISE IFW50--01 to 04/11 to 14/21 to 24 Caution PSE 1.
For heavy stains, use a cloth soaked with diluted neutral detergent and fully squeezed, then wipe up the stains again with a dry cloth. -7No.PS-OMG0006-D Model Indication and How to Order Option Description Part number Remarks Connector for pressure sensor controller ZS-28-C 1 pc. Adapter with throttle Rc1/4 ZS-31-X175 1 pc. Adapter with throttle NPT1/4 ZS-31-X186 1 pc.
1 Rod seal CQ2B32V-PS CQ2B32R-PS CQ2B40V-PS CQ2B40R-PS Set of left nos. !0, !1, !2. !2 Tube gasket CQ2B50V-PS CQ2B50R-PS CQ2B63V-PS CQ2B63R-PS 13 Rod scraper CQ2B80V-PS CQ2B80R-PS CQ2B100V-PS CQ2B100R-PS R: NBR seal (Nitrile rubber) V: FKM seal (Fluororubber) Seal kit includes !0, !1, !2. Order the seal kit, based on each bore size.
1 Rod seal CQ2B32V-PS CQ2B32R-PS CQ2B40V-PS CQ2B40R-PS Set of left nos. !0, !1, !2. !2 Tube gasket CQ2B50V-PS CQ2B50R-PS CQ2B63V-PS CQ2B63R-PS 13 Rod scraper CQ2B80V-PS CQ2B80R-PS CQ2B100V-PS CQ2B100R-PS R: NBR seal (Nitrile rubber) V: FKM seal (Fluororubber) Seal kit includes !0, !1, !2. Order the seal kit, based on each bore size.
320 (mm) 3300.05 Arm type A B C T200 T240 T270 200 340 29 240 360 19 270 380 9 Note 1) This product does not include the limit switch.
32 H L CBQ2 Standard A93 S B 50 D C CDBQ2 With Auto Switch 32 H L Number of auto switches With auto switch (built-in magnet) 2 pcs. 1 pc.
Note) D: Max. diameter 7 8.4 12.7 13.2 15.2 15.4 15.3 M5 x 0.8 T 2.6 2.2 R 1 8 10 0.8 0.8 13 13.7 15.1 15.3 15.7 14.7 16.7 M3 x 0.5 M5 x 0.8 VMG 7 9.3 15.6 12.7 4
When 1 digit = 1 kPa, the pressure is given with an increment Digit (Min. setting unit) of 1 kPa, e.g., 1, 2, 3,, 99, 100. E Energy saving automatic control Indicate that the vacuum pressure during adsorption is monitored and ON and OFF of the ejector is automatically controlled.
(mm) M Effective area (mm 2) Weight (g) A L2 L1 1 8 1 4 1 8 1 4 3 8 1 8 1 4 3 8 1 4 3 8 1 2 1 4 3 8 1 2 DL04-01 15 3.5 23 DL04-02 17 19 4 10 23.5 19.6 10 30 DL06-01 25 17 Applicable tubing 19.6 10 23.5 DL06-02 16 19 31 14 6 9 12 DL06-03 22 53 26.5 24.5 21.6 22.6 24.5 25.8 24.5 29.4 29.6 30.3 29.4 91 Reference dimensions after R thread installation.
Instance attribute ID Access rule Description Value 1 Get/Set 1 MAC ID 0-63 2 Get/Set 1 Baud Rate 0-2 3 Get/Set BOI 0-1 4 Get/Set Bus-off Counter 0-255 5 Get Allocation Information 6 Get MAC ID Switch Changed 0-1 7 Get Baud Rate Switch Changed 0-1 8 Get MAC ID Switch Value 0-63 9 Get Baud Rate Switch Value 0-2 10 Set Quick Connect 0-1 1: Set is available in SW mode. -16No.EX-OMO0004-D 3-4
Default: Gain 9 Bit Bit 3, 2, 1, 0 Value 3 2 1 0 Setting Bit 0 0 0 0 Gain 0 0 0 0 1 Gain 1 0 0 1 0 Gain 2 0 0 1 1 Gain 3 0 1 0 0 Gain 4 0 1 0 1 Gain 5 0 1 1 0 Gain 6 0 1 1 1 Gain 7 1 0 0 0 Gain 8 1 0 0 1 Gain 9 1 0 1 0 Gain A 1 0 1 1 Gain B 1 1 0 0 Gain C 1 1 0 1 Gain D 1 1 1 0 Gain E 1 1 1 1 Gain F * indicates the initial shipping value. 3 Doc.No.DIT-69900-OM005-E Parameter index 0x43 Parameter
Vacuum pads are excluded from this 1 year warranty. Vacuum pads are excluded from this 1 year warranty. Vacuum pads are excluded from this 1 year warranty. Vacuum pads are excluded from this 1 year warranty. Vacuum pads are excluded from this 1 year warranty. A vacuum pad is a consumable part, so it is warranted for a year after it is delivered.
Figure 5-1 6. Maintenance 6-1. Daily check 1) Smoothness of the operation 2) Changes in piston speed and cycle time 3) Proper stroking 6-2.
N03 T03 NPTF 1/4 Threads Rc 1/4 Threads G 1/4 Threads NPT 1/4 Threads P11 P11F Compact, lightweight (Without foot) P11N P11T PAP331 (Assembled in clean room) NPTF 1/4 Threads Rc 1/4 Threads G 1/4 Threads NPT 1/4 Threads P13 P13F 140 mm 120 mm P13N P13T NPTF 1/4 Threads 110 mm Option Reset button Weight: 2.1 kg Air operated type is also standardized.
69 M4 x 0.7 6 4.5 67 M5 x 0.8 25 60 105 48 45 23 13 18 69 32 17 2.5 118 CYP32 8.6 115 M6 x 1 8 7.5 90 Rc 1/8 50 100 138 87 79.5 29 17 22 115 46 27 3.5 155 Note 1) These dimension drawings indicate the case of piping port position "Nil".
pressure value (main display). (1) Press and hold the button between 1 and 3 seconds in measurement mode.
) [External pilot specification] Lead wire length 200 mm Manual override 1/4 (PE port) 2 (EXH port) NO NC PE PA 2 x 13 (Mounting hole) 31 185.3 130 130 95 80 IN EXH OUT 52 52 14 41 118 2 1 1/4, 1 1/2, 2 (IN, OUT port) 105 Note) External pilot port (PA port) 1/4 is processed for threads in external pilot model only.
1.5~2 SMC AF AR 4. 4-1 13 - 4-2 1 15 2 16 3 17 B 4 18 5 19 6 20 7 21 U 8 22 R 9 A 23 C 10 B 24 11 A 25 12 13 14 MHL2-10D MHL2-16D MHL2-20D MHL2-25D MHL2-32D MHL2-40D 26 27 28 29 30 NBR MHL10-PS MHL16-PS MHL20-PS MHL25-PS MHL32-PS MHL40-PS ) 262627282930 1 14 - 4-3 1 U U 2 R B B R 3 15 - 4-4 1 2 O O O 3 16 - Revision history 4-14-1, Sotokanda, Chiyoda-ku