Function: 1 (2 Position Single), Body Option: 1 (Base Mounted Non Plug-in), Direct Manual Override: 0 (Standard), Pilot: Internal Pilot, Voltage: 1 (100VAC 50/60HZ), Lead Wire: E (Grommet Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 04 (Sub-plate Plug-in Terminal 1/2, Non Plug-in Standard
Function: 1 (2 Position Single), Body Option: 1 (Base Mounted Non Plug-in), Direct Manual Override: 1 (Direct Manual Override), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: B (Locking Slotted Style), Piping: Side Ported (Or None in Case of w/o Subplate), Port Size: 04 (Sub-plate Plug-in Terminal 1
Plug-in Terminal 1/2, Non Plug-in Standard 1/2), Thread: N (NPT)
1/2, Non Plug-in Standard 1/2), Thread: T (NPTF)
1/2, Non Plug-in Standard 1/2), Thread: N (NPT)
Plug-in Terminal 1/2, Non Plug-in Standard 1/2), Thread: T (NPTF)
The series is offered in sizes ranging from 1/8 to 1/2 metric R(PT). Speed controller with residual pressure release valve with one-touch fittings; Body sizes: 1/8, 1/4, 3/8, 1/2; Elbow or universal style; Meter-in or meter-out control; Port sizes: 01, 02, 03, 04; Tube sizes O.D. (mm): 4, 6, 8, 10, 12
The series is offered in sizes ranging from 1/8 to 1/2 metric R(PT). Speed controller with residual pressure release valve; Body sizes: 1/8, 1/4, 3/8, 1/2; Port sizes: 01, 02, 03, 04
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 1 (Meter-in), Indicator Direction: 1(180°), Thread: R, Port Size: 02 (1/4), Applicable Tubing O.D.: 04 (ø4), Seal: S (w/Sealant)
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 1 (Meter-in), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 01 (1/8), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 04 (ø4), Sealant: S (with Sealant), Push lock: A (Push-lock)
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 1 (Meter-in), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 01 (1/8), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 04 (ø4)
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 1 (Meter-in), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 01 (1/8), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 04 (ø4), Sealant: S (with Sealant)
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 1 (Meter-in), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 02 (1/4), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 04 (ø4), Sealant: S (with Sealant)
Body Size: 2 (1/8, 1/4), Type: 3 (Universal), Control Type: 1 (Meter-in), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 01 (1/8), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 04 (ø4)
Body Size: 2 (1/8, 1/4), Type: 3 (Universal), Control Type: 1 (Meter-in), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 01 (1/8), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 04 (ø4), Sealant: S (with Sealant)
Body Size: 2 (1/8, 1/4), Type: 3 (Universal), Control Type: 1 (Meter-in), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 02 (1/4), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 04 (ø4), Sealant: S (with Sealant)
/N.C.), 3rd Selection Vacuum V Port: 6 (Vacuum, V Port: Ø6), 3rd Selection Quantity: 1, /: /, 4th Nominal Nozzle Size: 4 (ø1.5), 4th Selection Supply Valve and Release Valve: K (N.C./N.C.), 4th Selection Vacuum V Port: 6 (Vacuum, V Port: Ø6), 4th Selection Quantity: 1
Actuation Type: 1 (2 Position Single), Sealant: 1 (Rubber Seal), Function: Standard (1W), Voltage: 1 (100VAC 50/60HZ), Lead Wire: H (Grommet Lead Wire 1.5m), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style, Protection: W (IP65 Protection Compatible), 1: 1, Piping Specification: Side Ported, Port Size: 04 (Rc1/2), Thread: N (NPT)
Terminal 1/2, Non Plug-in Standard 1/2), Thread: T (NPTF)