B (9.5) B (12.7) B (19.1) B (25.4) B (31.8) B (38.1) B (50.8) VNA 111 211 311 411 511 611 711 AS 420-03 420-04 500-06 600-10 800-12 900-14 900-20 3 8 1 2 3 4 10A 15A 20A 25A 32A 40A 50A 1 2 VNA01 VNA02 VNA03 VNA1 Port 12 (P1) 1 1 1 2 External pilot External pilot External pilot External pilot External pilot Pilot exhaust Bleed port Bleed port 1 4 1 2 10 (P2) Installing a silencer to the
0 C +0.5 0 4-Rc 1/4, 3/8 4 (B) B 0.1 Max. panel thickness D (mm) A 3.2 3.2 3.2 Model B 40 51 64 C 35 41 51 D 3.5 6 8 VH200 VH300 VH400 3.6-12 Series VH Panel Mounted/Dimensions VH41l-02 to 04 VH41l-06 2 (A) 4 (B) 4 (B) 2 (A) 25 25 3 (R) 1 (P) 3 (R) 1 (P) 107.5 19 l102 102 89 88 4-6.6 4-6.6 88 81 94 148 144 97 97 67 1.5 65 1.5 125 123 105.5 3 (R) 3 (R) 1 (P) 1 (P) 25 17 2 4-Rc1/4, 3/
3 A-y A-u A-i A-y B-q B-w B-e B-r B-w B-t B-y B-t Orifice body PTFE seal O-ring Sleeve O-ring O-ring O-ring Name plate O-ring O-ring Orifice body Name plate O-ring O-ring O-ring O-ring Orifice O-ring O-ring Name plate O-ring O-ring O-ring O-ring PEEK resin Special PTFE Special FKM POM Special FKM Special FKM Special FKM Special FKM Special FKM PEEK resin Special FKM Special FKM HNBR Special
Low Speed Cylinder Double Acting, Single Rod Series CQSX 12, 16, 20, 25 How to Order CQSX D B 20 30 Without auto switch 30 F9BW B 20 CDQSX D With auto switch Number of auto switches Built-in magnet 2 pcs. 1 pc. n pcs.
Applicable bore (mm) 6 Applicable bore (mm) 6 NX NDH10 B L1 R1 R2 U A Part no. A B L L2 MM R1 R2 U L2 MM L1 NDd9 3 NDH10 3 NX Part no.
Cv C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv VT325 VT325V (Vacuum spec. type) VT325 VT325V (Vacuum spec. type) 0.55 kg (For AC) 0.60 kg (For DC) Note) Values for a single valve unit.
01 B 06 B 1 8 3 4 1B Accessory 02 03 10 14 B 1 4 B 3 8 04 B 1 2 1 4 1 B 1 2 20 2B Option IN-OUT reversal direction -T Element service indicator AFF75A to AFF220A AFF 75A 20 D Accessory (Option) Basic size (Applicable compressor rating) D Auto-drain G Pressure gauge F Companion flange L Anchor bolt 75A 75 kW 125A 110 to 125 kW 150A 150 kW 220A 180 to 220 kW Port size 20 2BJIS 10k flange 30
Setting Position (mm) D-C7 D-C8 D-C73C D-C80C D-G39 D-K39 D-A33, A34 D-A44 D-B5 D-B6 D-H7l D-H7C D-G5NTL D-H7lW D-H7lF D-H7BAL D-B59W Bore size (mm) A B A B A B A B A B A B A B 20 56.0 31.5 50.0 25.5 55.0 30.5 51.5 27.0 53.5 29.0 53.0 28.5 49.5 25.0 25 56.0 31.5 50.0 25.5 55.0 30.5 51.5 27.0 53.5 29.0 53.0 28.5 49.5 25.0 32 59.5 36.5 53.5 30.5 58.0 35.5 55.0 32.5 57.0 34.0 56.5 33.5 53.0
Example Rail mounting style CDJ2XB10-45-A Band mounting style CDJ2XB16-60-B Applicable Auto Switch/Refer to page 10-20-1 for further information on auto switches.
Applicable bore (mm) 6 Applicable bore (mm) 6 NX NDH10 B L1 R1 R2 U A Part no. A B L L2 MM R1 R2 U L2 MM L1 NDd9 3 NDH10 3 NX Part no.
x 103 Yaw moment M3 = m x g x (L + A) x 103 Roll moment M2 = m x g x (L + B) x 103 (mm) Model CYP15 CYP32 A 16.5 27.0 B 25.5 48.0 L B L B L A M1, 2, 3 : Moment [Nm] m : Load mass [kg] L : Distance to load center of gravity [mm] A, B : Distance to guide shaft [mm] g : Gravitational acceleration [9.8 m/s2] M2 M1 M3 m x g m x g Guide shaft mounting surface Guide central axis m x g Cylinder
Unit Series AV2000-A AV3000-A AV4000-A AV5000-A Spacer Y200-A Y300-A Y400-A Y600-A Spacer with bracket Y200T-A Y300T-A Y400T-A Y600T-A Applicable model AC20-A AC20-B AC25-A, AC30-A AC25-B, AC30-B AC40-A*1 AC40-B*1 AC50-B, AC55-B AC60-B *1 Except port size 06 Assembly Example eSpacer with bracket qSoft start-up valve Air combination wAC30-03G-A Assembly example Products do not come assembled
AP100 17 735 ARM11A/B Series Pressure Switch Block 56 ARM11AW Z A 0.4 0.2 0.6 0.5 20 MPa 24 q w 0.3 0.1 1. Accessory 2.
setting status signal B EnabledOpen A Output the input signal as it is SW1 Pass through signal of the contact input signal 1 B Reverse output of the input signal A Output the input signal as it is SW2 Pass through signal of the contact input signal 2 B Reverse output of the input signal A Selected alarm occurrence : Close A.SEL Selected alarm status signal B Selected alarm occurrence : Open
5-2.Dimensions C E C E E (KF flange) Fd (K flange) Fn D H B A G A Unit: mm Model A B C D E Fn Fd G H XLA-16-2 40 108 38 20 30 17 44 XLA-25-2 50 121 48 27 12 40 26 44 XLA-40-2 65 171 66 39 11 55 41 67 XLA-50-2 70 185 79 46 11 75 52 72 XLA-63-2 88 212 100 55 11 87 95 70 76 XLA-80-2 90 257 117 65 11 114 110 83 104 12 XL-OMS0001-B 6.
Comply with the requirements for FISCO field device Class I, Division 2, Groups A, B, C, and D; T4/ T5/T6 Ex ic IIC T4/T5/T6 Gc Class I, Zone 2 AEx ic IIC T4/T5/T6 Gc Ui 32 V, Ii 380 mA, Pi 5.32 W, Ci 5 nF, Li 10 H.
Adjustment bolt b CRA1 Adjustment bolt d CRQ2 q First adjust both rotation end positions. Apply pressure to ports A and C to adjust adjusting bolt b. Apply pressure to ports B and D to adjust adjusting bolt a. Lock the bolts with fixing nuts after adjustment. w Next, apply pressure to ports A to D to adjust the center position. Loosen the fixing nuts for adjusting bolts c and d.
Nil M5 x 0.8 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/4 TF G 1/8 G 1/8 G 1/8 G 1/4 TN NPT 1/8 NPT 1/8 NPT 1/8 NPT 1/4 CY3B15 CY3B20 CY3B25 CY3B32 CY3B40 b C H B d M10 x 1.0 M20 x 1.5 M26 x 1.5 M32 x 2.0 H 4 8 8 10 B 14 26 32 41 C 16.2 30 37 47.3 Part No.
The pressure difference generated at this time opens check valve and the residual pressure on the A port side is quickly exhausted from R port. 2 1(P) OFF 2(A) 1 3(R) 3 Soft Start-up Valve AV2000/3000/4000/5000 Construction B ON OFF B-B 1(P) 2(A) B 3(R) Parts list No. 1 2 3 Description Material Body Cap Cover ADC ADC ADC Replacement parts Description No. Part no.
M5 x 0.8 b Cv b Cv VV3Z1-01-1 VV4Z1-20-1 1/8 How to Order Manifold Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with the manifold base model no.