Piping: Body Ported, Stations: 12 Stations, A, B Port: NPT
Piping: Body Ported, Stations: 12 Stations, A, B Port: NPT
Manifold Type: Body Ported, Valve Stations: 12 Stations, A, B Port: NPT
Manifold Type: Body Ported, Valve Stations: 12 Stations, A, B Port: NPT, CE Marked: -
Refer to pages 5-12-2 to 6 for Safety lnstructions and Solenoid Valve Precautions. Mounting Definition of Symbol Warning 1. Conditions for mechanical operation Do not move the mechanical operation beyond the operating limit position, as this could damage the mechanical valve itself and lead to equipment malfunction.
They do not guarantee an actual fixed range (expect approximately 30% dispersion).
a) .250 \-24 0.50 .624 .621 0.25 0.86 0.38 it-l6 .251 .zfi 0.75 0.25 o.34 It.oo o.75 o.62 o.12 # 1 8 o.75 1-?
Do not use with flammable or highly permeable fluids. Fire, explosion, damage or corrosion can result.
When PF3W7 (IO-Link) is used SIO mode setting Main piping Pin No Name Lead wire colour Function Attachment 1 DC(+) Brown 12 to 24 VDC Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof. Mounting and Installation 2 N.C.
Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. 5% of rated flow Hysteresis Setting of hysteresis can prevent chattering. UP button Selects a mode and the display shown at the sub screen, and increases the ON/OFF set values.
Do not use an open tank. Ensure that the INLET and OUTLET for circulating fluid is connected correctly. If any valves are used ensure that they do not restrict the flow, otherwise low flow my cause an alarm. 3.5 Handling Transport Thermo-con with both handles.
Do not use in an atmosphere where corrosive gases, chemicals, sea water, water, or water steam is present. Do not use in cases where there is direct contact with any of the above. 2. Do not use in a place subject to heavy vibration and/or impact. 3. Do not use in an environment where flammable gas or explosive gas is present. Usage may cause a fire or explosion.
Do not use at temperatures (fluid or ambient temperatures) higher than the prescribed operating conditions.
Regulator and filter regulator 1) Be sure to unlock the handle before adjusting the pressure and to lock it after the pressure is set. 2) During transport and installation, do not apply shock to the product, such as by dropping doing so will affect its precision. 3) Do not install it iin an area that is exposed to high temperature or humidity, because doing so will lead to improper operation
Please make sure that operating conditions do not cause problems since the use of FEP tubing under chemical environment is unsecured.
When this is done, take care that the coverings of the lead wires do not enter the core wire crimping area. (Crimping tool: model no. DXT170-75-1) 1. Do not use with thinner, carbon tetrachloride, chloroform, acetate, aniline, cyclohexane, trichloroethylene, sulfuric acid, lactic acid and watermiscible cutting fluid (alkaline). 2. Operate it away from direct sunlight.
Model Wrench size (Bowl) Tightening torque Wrench size (Socket) Tightening torque JT20 Width: 22 mm 12 Nm Width: 10 mm 8 to 12 Nm JT32 Width: 27 mm 24 Nm Width: 12 mm 15 to 24 Nm JT40 Width: 36 mm 68 Nm Width: 17 mm 40 to 68 Nm 4. Use a cylinder with a built-in cushion mechanism.
12 13 12 8 8 12 13 12 14 14 6 18 18 23 23 7 7 19 24 20 Note) When mounting and removing the product, apply a wrench or torque wrench to the place shown in Figure.
Do not use the product in a place where static electricity is a problem.
Do not service or attempt to remove product and machinery/equipment until safety is 3. Do not service or attempt to remove product and machinery/equipment until safety is 3. Do not service or attempt to remove product and machinery/equipment until safety is 3. Do not service or attempt to remove product and machinery/equipment until safety is 3.