SMC Corporation of America
Elite Part Number Search
Search Results "VVXA221-04-1"

Body Size: 40, Thread: N (NPT), Port Size: 04 (1/2), Option: Standard, Semi-Standard 1: J (Drain Guide: 1/8 for Body Size 20; 1/4 for Body Size 30 & 40), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)

Body Size: 40, Thread: F (G), Port Size: 04 (1/2), Option: Standard, Semi-Standard 1: J (Drain Guide: 1/8 for Body Size 20; 1/4 for Body Size 30 & 40), Semi-Standard 2: Standard

Body Size: 40, Thread: N (NPT), Port Size: 04 (1/2), Option: B (Bracket), Semi-Standard 1: J (Drain Guide: 1/8 for Body Size 20; 1/4 for Body Size 30 & 40), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)

Body Size: 40, Thread: N (NPT), Port Size: 04 (1/2), Option: B (Bracket), Semi-Standard 1: J (Drain Guide: 1/8 for Body Size 20; 1/4 for Body Size 30 & 40), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F), Made to Order: X2141 (w/Element Service Indicator)

Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min;

Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: CT (Out 1: NPN; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated

Valve: None; Stop Valve: None, Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)

Valve: None; Stop Valve: None, Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)

Valve: None; Stop Valve: None, Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)

Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)

Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal; Temp

Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)

Valve; Stop Valve: None), Return Port Size: 04 (1/2), Flow Switch Output Specifications: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)

Valve: None; Stop Valve: None, Return Port Size: 04 (1/2), Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)

Valve: None; Stop Valve: None, Return Port Size: 04 (1/2), Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)

Body Size: 4 (1/2), Type: 3 (Universal), Control Type: 1 (Meter-in), Indicator Direction: 1 (180°), Thread: R, Port Size: 04 (1/2), Width Across Flats: 9mm, Tubing: 10 (ø10)

Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 0 (Meter-out), Indicator Direction: 1 (180°), Thread: N (NPT), Port Size: 01 (1/8), Width Across Flats: 9mm, Tubing: 04 (ø4)

Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 0 (Meter-out), Indicator Direction: 1 (180°), Thread: N (NPT), Port Size: 02 (1/4), Width Across Flats: 9mm, Tubing: 04 (ø4), Seal: S (w/Sealant)

Body Size: 2 (1/8, 1/4), Type: 3 (Universal), Control Type: 0 (Meter-out), Indicator Direction: 1 (180°), Thread: G, Port Size: 01 (1/8), Width Across Flats: 9mm, Tubing: 04 (ø4)

Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 1 (Meter-in), Indicator Direction: None (0°), Thread: N (NPT), Port Size: 02 (1/4), Width Across Flats: 9mm, Tubing: 04 (ø4), Seal: S (w/Sealant)