30% 50% 70% 10% 30% 50% SY 150 300 Stroke (mm) 70% Stroke (mm) AS2201F -01-06 AS2200-01 AS2201F -01-08 AS2200-01 70% 100 SYJ 200 50 SX 100 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 10% 30% 50% 70% 50% 30% 10% 0 0 200 CM2 25 400 MB 40 150 300 Stroke (mm) Stroke
PF2W504--1 PF2W520--1 PF2W540--1 PF2W511--1 PF2W504--2 PF2W520--2 PF2W540--2 PF2W511--2 4 0.5 4 0.5 16 2 16 2 40 5 40 5 100 10 100 10 23 Digital Flow Switch Series PF2W For Water Dimensions: Remote Type Display Unit for Water PF2W3-A Panel mounting type Internal circuits and wiring examples to are the terminal numbers.
Hs 30.5 35 40.5 47.5 D-H7C 15 65 10 65 + 50 (n-2) A B Approx. Hs 3 5.5 7 7 n-2 2 D-H7C 31.5 28.5 30 30 15 + 50 ( ) (n = 2, 4, 6...) D-G5NTL 75 + 50 (n-2) 15 75 30.5 38 43 50 A B 0 (1) 0.5 2 2 D-A3 D-G3, D-K3 100 + 100 (n-2) 35 + 30 (n-2) 35 100 D-B5, D-B6 33.5 23.5 25 25 Approx.
(0.7) F (C) Inlet air temperature 100 (37.8) IDFB IDFB F (C) Ambient temperature 100 (37.8) Single-phase 115 VAC [voltage fluctuation 10%] 60 Hz Single-phase 230 VAC [voltage fluctuation 10%] 60 Hz Three-phase 460 VAC [voltage fluctuation 10%] 60 Hz Power supply voltage (frequency) IDH (A) Operating current Note 5) 9 4.5 5.6 3.8 ID (W) Power consumption Note 5) 1000 1270 2400 Applicable
10 20 30 40 50 100 200 300 Fs Fs + mgs Fsmgs 400 500 Absorbed energy E W2 max.
5 0.5 0 0 0.1 0.2 0.4 0.5 0.3 0.2 0.4 0.5 0.3 Operating time (s/90) Operating time (s/90) MHY2-20D MHW2-32D 6 50 Moment of inertia (x 10-4 kgm2) Moment of inertia (x 10-4 kgm2) 5 40 4 30 3 20 2 10 1 0 0 0.2 0.4 0.6 0.8 0.2 0.4 0.5 0.3 0.6 Operating time (s/90) Operating time (s/90) MHY2-25D MHW2-40D 20 200 Moment of inertia (x 10-4 kgm2) Moment of inertia (x 10-4 kgm2) 15 150 10 100 5 50
5 0.5 0 0 0.1 0.2 0.4 0.5 0.3 0.2 0.4 0.5 0.3 Operating time (s/90) Operating time (s/90) MHY2-20D MHW2-32D 6 50 Moment of inertia (x 10-4 kgm2) Moment of inertia (x 10-4 kgm2) 5 40 4 30 3 20 2 10 1 0 0 0.2 0.4 0.6 0.8 0.2 0.4 0.5 0.3 0.6 Operating time (s/90) Operating time (s/90) MHY2-25D MHW2-40D 20 200 Moment of inertia (x 10-4 kgm2) Moment of inertia (x 10-4 kgm2) 15 150 10 100 5 50
It can be used in the vacuum (up to 100 kPa) or low pressure line with 0.15 MPa or less.
10 0 0 10 30 40 50 20 60 10 20 Discharge rate l/min Discharge rate l/min Selection from flow rate characteristic graphs (PA3000) Required specification example: 3.
Current consumption: 10 mA or less Switch output signal 5 points, N-type MOSFET Open source output Maximum load current: 100 mA 4-3.
Symbol x 50 001 005 010 020 050 075 100 002 004 006 013 q q w w 0.01 0.01 e r e 0.005 0.005 r 0.002 5 10 50 100 0.002 10 50 100 Flow rate l/min (ANR) Flow rate l/min (ANR) Note) The recommended flow rate is the rate for an initial pressure drop of 0.01 to 0.02 MPa. 2 Series FQ1 How to Order Filters Element and Seal Part Numbers 1.
64 53.5 10 to 50 63.5 17.5 depth 13.5 80 73.5 63.5 21 25 98 12.5 M16 x 2.0 132 6 22 10 77 11 3/8 16 112.5 57.5 26 63.5 75, 100 73.5 63 10 to 50 75 17.5 depth 13.5 100 85 73 27 30 117 13 M20 x 2.5 156 6.5 27 12 94 11 3/8 23 132.5 67.5 26 73 75, 100 85 7
Allowable Kinetic Energy Extension locking direction Retraction locking direction 100 100 50 50 Load weight kg Load weight kg 10 10 50 W 50 5 5 40 40 B 32 32 0.5MPa 0.4MPa 0.5MPa 0.4MPa A A 25 25 1 1 100 500 100 500 B W Maximum speed mm/s Maximum speed mm/s B: Retraction locking direction F: Extension locking direction 9-13-4 4 Series MLU Specific Product Precautions 2 Be sure to read before
Symbol x 50 001 005 010 020 050 075 100 002 004 006 013 q q w w 0.01 0.01 e r e 0.005 0.005 r 0.002 5 10 50 100 0.002 10 50 100 Flow rate l/min (ANR) Flow rate l/min (ANR) Note) The recommended flow rate is the rate for an initial pressure drop of 0.01 to 0.02 MPa. 2 Series FQ1 How to Order Filters Element and Seal Part Numbers 1.
10 G 1 K 5 Straight 15 15 H 2 M 10 Straight N None J 3 S 3 To use AC adapter, specify "N", and select AC adapter with the option number.
It can be used in the vacuum (up to 100 kPa) or low pressure line with 0.15 MPa or less.
Slider type LEKFS series 2.1 Specification AC servo motorMotor typeS*/T*) Model LEKFS25 LEKFS32 LEKFS40 Stroke [mm] 100 to 500 100 to 500 200 to 600 Horizontal 10 20 20 30 40 45 30 50 60 Work load [kg] Note1) Vertical 4 8 15 5 10 20 7 15 30 Up to 400 1500 900 450 1500 1000 500 1500 1000 500 401 to 500 1200 720 360 1500 1000 500 1500 1000 500 501 to 600 900 540 270 1200 1000 500 1500 1000
SY11 A 3 4 M3 x 0.5 M3 x 0.5 100 kPA to 0 0.22 100 kPA to 0.6 Large flow 0 to 0.7 N.C. SY13(A): 15 SY14(A): 26 (14) SY13(A): 13 SY14(A): 24 (12) (1) SY12 3 4 M3 x 0.5 M3 x 0.5 100 kPA to 0.6 0.14 100 kPA to 0 Standard 0 to 0.7 N.O. (1) SY12 A 3 4 M3 x 0.5 M3 x 0.5 100 kPA to 0.6 100 kPA to 0 0.22 Large flow 0 to 0.7 N.O.
125 25 50 75 100 Courtesy of Steven Engineering, Inc. !
to 1000 up to 1000 up to 1000 102.5 122 1.7-28 Low Friction Series MBlQ With Mounting Bracket Front flange/(F) Front flange (mm) Port Cushion valve 4-FD Bore size (mm) Stroke range Fd FZ FY FX FT FE FD B 32 40 50 63 80 100 25 31 38.5 39.5 45.5 54 79 90 110 120 153 178 32 36 45 50 63 75 64 72 90 100 126 150 10 10 12 12 16 16 3 3 2 2 4 4 7 9 9 9 12 14 up to 700 50 55 70 80 100 120 up to 800