ERR LED No.3 L RUN LED or SI No.4 L ERR LED No.5 SI or L ERR LED No.6 or No.7 LED No.8 LED No.9 -21No.EX-OMP0004CN-I No.1 () SI PWR LED SI DC24 V10 No.2 () SI PWR(V) LED DC24 V 10/-5 No.3 CC-Link SI L ERR LED SI L RUN LED SI SI SI -22No.EX-OMP0004CN-I No.4 SI L ERR LED SI L RUN LED SI SI No.5 SI L ERR LED SI L RUN LED SI SI No.6 SI SI SI SI L ERR LED SI
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: Rc, Port Size: 06 (3/4), Output Specification/Temperature Sensor: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature
Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: F (G), Port Size: 04 (1/2), Output Specification/Temperature Sensor: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: J (Instantaneous Flow: L/min, Accumulated Flow: L, Temperature
11 5.5 M3 x 0.5 8 L 12 7 M4 x 0.7 8 10 A 15 8.5 M5 x 0.8 1214
Cushion seal L Guide gasket M Piston gasket Replacement Parts: Lock-up Unit K, L and M are non-replaceable parts, so they are not included in the seal kit. CL 40 TN Port thread type Bore size (mm) Nil Rc NPT G TN TF Consult with SMC when replacing the lock-up unit with a bore size of 125 to 160. 154
min (ANR)) Flow rate (L/min (ANR)) AEP HEP Construction i e AL800/900 r y q IN OUT t o !
Description Material ARM1000 ARM2000 134819-30#1 13615 13614 KA00347 16.5 x 13.5 x 1.5 KA00476 JIS B 2401 P7 (Initial setting) Inlet pressure: 0.7 MPa Outlet pressure: 0.2 MPa Flow rate: 10 L/min (ANR) 7 8 9 13626-30#1 13625 13624 KA00361 23 x 20 x 1.5 KA00087 JIS B 2401 P8 Valve Valve spring Valve guide Brass, HNBR Stainless steel Polyacetal 10 O-ring NBR Initial set point 11 O-ring NBR
2% F.S. or less, allowable load resistance: 100 k or moreCurrent output Note 6) 4 to 20 mALinearity: ?2% F.S.or less, allowable load resistance: 300 or less with 12 VDC, 600 or less with 24 VDC12 to 24 VDC (ripple ?10% or less)20 mA or less (without load)IP65Operating: 0 to 50C, Stored: ?
Standard settings of L dimensions are with 10 or less m blocks. Contact SMC sales for the setting with over 10 blocks mounted. The direct current power supply to combine should be UL1310 Class2 power supply when conformity to UL is necessary.
L Warning: WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Angled connector type EX500-AC -SAPA (unit: mm) 3 Danger: DANGER indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: Rc, Port Size: 03 (3/8), Output Specification/Temperature Sensor: KT (OUT1: Analogue 4 to 20 mA - OUT2: Analogue 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C), Bracket
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: F (G), Port Size: 04 (1/2), Output Specification/Temperature Sensor: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C),
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: F (G), Port Size: 03 (3/8), Output Specification/Temperature Sensor: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature:
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: Rc, Port Size: 04 (1/2), Output Specification/Temperature Sensor: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C),
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: F (G), Port Size: 10 (1), Output Specification/Temperature Sensor: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: DT (Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature