Double acting single rod only 35, 40, 45, 50, 75, 100 5, 10, 15, 20, 25, 30 12, 16 5, 10, 15, 20, 25, 30 75, 100, 125, 150, 175, 200 75, 100, 125, 150, 175, 200, 250, 300 20 5, 10 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 25 Applicable Auto Switches Mounting Bracket Part No.
, 250, 300, 350, 400, 450, 500, 600, 700, 800 25 4000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 32 5000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 40 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 6000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 63 Note1) Contact P/A in case of a stroke length beyond the maximum.
5 Port Solenoid Valve Series VQC Lateral Plug-In Manifold Style Wide Range of Electrical Entries Manifold Options Conforming to 1P67 NEW CONCEPT Connector Type Manifold Series VQC1000/2000/4000 Outstanding response times and long life Conforming to IP67 for protection from dust and moisture (Metal seal: Single type with light and surge suppressor) VQC1100: 10ms 2ms; 200 million cycles VQC2100
Configuration Minimum equipment and wiring requirements to get started 1 Provided by customer Ex) 200 V AC (*1) 7 Provided 6 1 by customer 8 2 3 N PC 1 2 5 9 C D 11 21 10 4 (*2) U 2 Electric Actuators Ex) LEF V W Provided by customer 3 PLC (CC-Link master unit) 11 (*1) Refer to LECSC Operation Manual, Chapter 4 for further details if the power supply voltage is 100VAC. (*2) When wiring to
Cylinder Speed Chart Bore size Series CS1/CS2 Pressure 0.5 MPa, Load factor 50% Cylinder stroke 300 mm Average velocity (mm/s) System 125 140 160 180 200 250 300 1000 Vertically upward movement Horizontal movement 900 800 700 600 500 400 300 200 100 0 A 800 900 1000 700 600 500 400 300 200 100 0 B 900 1000 800 700 600 500 400 300 200 100 0 C 800 900 1000 700 600 500 400 300 200 100 0 D 800
Next, the viscosity of 15 mPas and the discharge rate of 200 l/min in the required specification example are converted to the discharge rate for fresh water. Since 48% of the fresh water discharge rate is equivalent to 200 ml/min in the required specifications, 200 ml/min 0.48 = approximately 420 ml/min, indicating that a discharge rate of 420 ml/min is required for fresh water. 3.
CAT.ES11-80 A 5-Port Solenoid Valve Series VQC NEW CONCEPT Connector Type Manifold Series VQC1000/2000/4000 Outstanding response times and long life Conforming to IP67 for protection from dust and moisture (Metal seal: Single type with light and surge suppressor) VQC1100: 10ms 2ms; 200 million cycles VQC2100: 20ms 2ms; 200 million cycles VQC4100: 17ms 3ms; 100 million cycles (Based on IEC529
" SO, "63 a.5 25, 50, 75, 100,125, 150, 175, 200, 250.300, 350. 400. 450, 500 40 " !
, 250, 300 131 90 27 16 45 49.5 64 M14 x 1.5 14 4.5 14 100, 125, 150, 175, 200, 250, 300, 400, 500 177 136 27 16 52 57 71.5 M14 x 1.5 24 5 14 200, 300, 500 193 144 32 20 64 71 85.5 M18 x 1.5 25.5 7 18 200, 300, 500 194 145 32 20 77 84 98.5 M18 x 1.5 21 7 18 T P L M N O Q X Z Bore size (mm) 32 40 50 63 41 34 5.5 M6 x 1 Rc 1/8 56 57.5 30 14 41 40 5.5 M6 x 1 Rc 1/8 62 64.5 30 14 49 50 6.6 M8
, 250, 300 177 136 27 16 52 57 71.5 M14 x 1.5 24 5 14 100, 125, 150, 175, 200, 250, 300, 400, 500 200, 300, 500 193 144 32 20 64 71 85.5 M18 x 1.5 25.5 7 18 200, 300, 500 194 145 32 20 77 84 98.5 M18 x 1.5 21 7 18 T P L M N O Q X Z Bore size (mm) 32 40 50 63 1 8 Rc 41 34 5.5 M6 x 1 56 30 14 57.5 1 8 Rc 41 40 5.5 M6 x 1 62 30 14 64.5 1 4 Rc 49 50 6.6 M8 x 1.25 61.5 35 19 76.5 1 4 Rc 49 60
RS Q G RS H A Relation of Liquid Entry and Sliding Distance Amount of liquid entry (g) x 15 RZQ 10 Standard cylinder MI W S Stainless steel cylinder 5 CEP1 0 50 100 150 200 Sliding distance (km) 250 300 CE1 Conditions Working fluid Air Pressure 0.5 MPa Liquid Water-soluble coolant Piston speed 200 mm/sec (60 cpm) CE2 ML2B Special scraper C J G5-S Exterior configuration reduces residual
M5 x 0.8 12-CY3B10 10 500 50, 100, 150, 200, 250, 300 12-CY3B15 15 1000 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 12-CY3B20 20 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Rc1/8 NPT1/8 G1/8 12-CY3B25 25 (Both sides) Non-lube 12-CY3B32 32 1300 Rc1/4 NPT1/4 G1/4 12-CY3B40 40 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 12-CY3B50 50 12-CY3B63 63
, 250, 300 131 90 27 16 45 49.5 64 M14 x 1.5 14 4.5 14 100, 125, 150, 175, 200, 250, 300, 400, 500 177 136 27 16 52 57 71.5 M14 x 1.5 24 5 14 200, 300, 500 193 144 32 20 64 71 85.5 M18 x 1.5 25.5 7 18 200, 300, 500 194 145 32 20 77 84 98.5 M18 x 1.5 21 7 18 T P L M N O Q X Z Bore size (mm) 32 40 50 63 41 34 5.5 M6 x 1 Rc 1/8 56 57.5 30 14 41 40 5.5 M6 x 1 Rc 1/8 62 64.5 30 14 49 50 6.6 M8
RS Q G RS H A Relation of Liquid Entry and Sliding Distance Amount of liquid entry (g) x 15 RZQ 10 Standard cylinder MI W S Stainless steel cylinder 5 CEP1 0 50 100 150 200 Sliding distance (km) 250 300 CE1 Conditions Working fluid Air Pressure 0.5 MPa Liquid Water-soluble coolant Piston speed 200 mm/sec (60 cpm) CE2 ML2B Special scraper C J G5-S Exterior configuration reduces residual
Long Stroke Stroke range (mm) Y X Z Bore size (mm) 12 50, 75, 100 32 7.5 7.5 16 50, 75, 100 32 7.5 7.5 20 75, 100, 125, 150, 175, 200 41 9 9 25 75, 100, 125, 150, 175, 200, 250, 300 44 11 11 8-27-8 9 Platform Cylinder Series CXT Dimensions: 32, 40 (N) X + Stroke S + Stroke H 4-M8 x 1.25 4-8.7 through, counterbore 14 depth 8 HP Depth 12 HG 12 Back side 4-M10 x 1.5 depth 15 (N) T PA T MX d
300 500 700 Average speed Va mm/s 50 100 200 300 500 700 Average speed Va mm/s Collision speed V mm/s Note) Use average speed to calculate static moment.
Cylinder stroke [mm] Bore size Standard stroke [mm] 12 (10 x 2) 16 (12 x 2) 10, 20, 30, 50, 100 20 (16 x 2) 25 (20 x 2) 20, 30, 50, 100, 150 Port thread type Nil M thread 12 to 32 Rc 32 (25 x 2) 40 (32 x 2) 50 (40 x 2) 63 (45 x 2) 80 (56 x 2) 100 (71 x 2) 40 to 100 TN NPT TF G 25, 50, 100, 150, 200 Refer to page 4 for intermediate strokes.
Current consumption 55 mA or less Protection Polarity protection Power supply voltage for sensor 1 Power supply voltage: 1.5 V Power supply current for sensor 2 Max.110 mA (However, the total power supply current of 4 input is 440 mA or less maximum) The total power supply current when used as an IO-Link device is 200 mA or less maximum Display accuracy (Linearity) 5.0%F.S.
Rated Rated Sensitivity voltage x size voltage current of leak [V] [A] current [mA] HRS012--10 HRS018--10 1-phase 100V AC(50Hz) 100 200 15 15 or 30 HRS01--10-T 1-phase 3 cores x Sharing 100V to 115V 14AWG (High pump head AC(60Hz) [Optional]) (3 cores x 2.0mm2) HRS012--20 HRS018--20 HRS024--20 1-phase 10 30 (including ground) 200, 200-230V AC 230 HRS0--20-T (50/60Hz) 15 30 (High pump head
Basic setting mode Main menu Alarm display menu Maintenance notif Power supply ON Circulating fluid outlet temperature Circulating fluid set temperature 200 ALm mANT 200 XXALM MENU MENU MENU / / / M no (N M circulating fluid return temp AL01 mT01 212 Alarm number (Alarm number minimum RET TEMP / / / M n mT02 AL02 014 Alarm number Circulating fluid outlet pressure PRESS / 79 Circulating fluid