SMC Corporation of America
Elite Part Number Search
Search Results "VM131F-01-06S"

Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/4 VZ One-touch fitting for 4 C4 Port size 4(A), 2(B) port One-touch fitting for 6 C6 M5 x 0.8 VF One-touch fitting for 5/32" B3 One-touch fitting for 1/4" B7 Flow Characteristics VFR Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R) Port size 1(P), 5/3(R) port Manifold 2(B), 4(A) port C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv VP4 VV5Z3-40 VV5Z3-41 VV5Z3-42-01

Model Pressure range *1 Indication unit Connection thread Note MPa Port size 01 Rc1/8 02 Rc1/4 R1/8 R1/4 G46-7-02-SRB 0 to 0.7 R1/4 G46-10-02-SRB 0 to 1.0 G46-4-01 to 02-SRB 0 to 0.4 MPa Set pressure range: 0.05 to 0.69 MPa 02 WR110 X215 *1: Do not apply more pressure than the max. pressure displayed. It may cause a malfunction.

I Shock resistance 100G to X, Y, 2 direction ( 3 times for each direction) Weight 1269 (Incl. 3m-long lead wire) Nolel)eHysleresls mode ZSE When the values 01 PI and P2 are the same or when PI >P2 wlthlll 2digits, the hysteresis will be aulomahcally 2digits for the set value of PI.

Port size Thread size R, Rc 1/8 R, Rc 1/4 R, Rc 3/8 R, Rc 1/2 R, Rc 3/4 R, Rc 1 R, Rc 1 1/4 R, Rc 1 1/2 Symbol 01 02 03 04 06 10 12 14 Connection type Type Male thread (with sealant) Female thread Symbol M F Plug Yes No No Yes Socket Yes Yes No No Availability Built-in check valve Note) A plug with check valve should be used in combination with a socket with check valve.

2 1 B 1 2 20 2B 1 4 B IN-OUT reversal direction T Element service indicator Option AMD800 to AMD1000 Self-standing type AMD801/901 Piping support type 20 01 AMD 8 20 00 AMD 8 Port size Body size Port size Body size 8 8 20 2B flange 30 3B flange 20 2B flange 30 3B flange 9 9 10 40 4B flange 40 4B flange 60 6B flange Type Type 00 With manual drain cock 10 With auto-drain 01 With manual drain

IDG60S to IDG100S IDG3 to IDG50 IDG3H to IDG50H IDG30L, IDG50L Port size Symbol Bore Size V IDG60 to IDG100 IDG60H to IDG100H IDG60L to IDG100L 3 5 10 20 30 50 60 75 100 01 1/8 02 1/4 IDG60S to IDG100S Note) Note) 03 3/8 04 1/2 Note 1) Element service indicator is also available. Refer to Made to Order Specifications on page 14-19-48.

How to Order X214 01 S AS 2 2 0 0 Body size Option Port size Model Thread type Control method Speed Controller with One-touch Fitting Elbow Type, Metal Body/Series AS Refer to How to Order in page 15-9-43 for standard specifications. How to Order X214 2 2 1 01 06 S AS 1FG Body size Option Applicable tubing O.D.


The part number of the standard AR20 to AR60 round type pressure gauge is “G36-10-01,” or “G46-10-01”(for the R thread type).
For example, the part number of the AR30-03BG-A pressure gauge is “G36-10-01.” Details on the round type pressure gauge (with color zones) can be found https://www.smcpneumatics.com/Part-Builder-Links_ep_2458-1.html?https://smccatalog.partbuilder.smcpneumatics.com/support/faq/en-jp/?ca_id=vacuum-regulators&fa_id=10961


The part numbers of standard AR20 to AR60 round type pressure gauges are “G36-10-01” and “G46-10-01”(for the R thread type).
For example, the part number of the AR30-03BG-A pressure gauge is “G36-10-01.”
Details on the round type pressure gauge (with color zones) can be found https://www.smcpneumatics.com/Part-Builder-Links_ep_2458-1.html?https://smccatalog.partbuilder.smcpneumatics.com/support/faq/en-jp/?ca_id=combination-units&fa_id=10974

.· Y210-□01-A, 02-A applicable models: AC20-A, AC20B-A, AC20C-A.· Y310-□01-A, 02-A applicable models: AC25-A, AC25B-A, AC25C-A · Y310-□01-A, 02-A applicable models: AC30-A, AC30B-A, AC30C-A.· Y410-□02-A, 03-A applicable models: AC40-A, AC40B-A, AC40C-A.· Y510-□02-A, 03-A applicable models: AC40-06-A, AC40B-06-A.· Y510-□02-A, 03-A applicable models: AC40C-06-A.

Body Size: 3 (1/8 Basis), Port Size: N01 [Cylinder Side (NPT 1/8) Pilot Port (10-32UNF)], Applicable Tube OD: Ø6, Lock Nut: J (Round)

Body Size: 4 (1/4 Basis), Port Size: F02 [Cylinder Side (R(PT)1/4) Pilot Port (G(PF)1/8)], Applicable Tube OD: Ø6, Lock Nut: J (Round)

Body Size: 4 (1/4 Basis), Port Size: 02 [Cylinder Side (R(PT) 1/4) Pilot Port (Rc(PT) 1/8)], Applicable Tube OD: Ø6, Lock Nut: J (Round)

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

AS: AS, Size: 2 (1/8, 1/4 Basis), Style 1: 2 (Elbow), Control Type: 0 (Meter-out), Thread: M5, 10-32UNF, R, Port Size: 02 (1/4), Tube Size: Ø6, Option: S (Sealant), Lock Nut: J (Round)

Lightweight, point-of-use ZH and ZU series vacuum generators combine design simplicity with high performance. Simply plug an air supply tube in one end, and vacuum is ready at the other end. The slim ZU generators are extra compact. The ZH and ZU immediate response may be quicker than central vacuum systems. Also, these generators are often smaller and lighter than the bulky vacuum lines

Lightweight, point-of-use ZH and ZU series vacuum generators combine design simplicity with high performance. Simply plug an air supply tube in one end, and vacuum is ready at the other end. The slim ZU generators are extra compact. The ZH and ZU immediate response may be quicker than central vacuum systems. Also, these generators are often smaller and lighter than the bulky vacuum lines

Nozzle Diameter: 07 (ø0.7mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: 06 (One-touch Fitting ø6), VAC: 06 (One-touch Fitting ø6), EXH: 06 (One-touch Fitting ø6), Accessories: S (w/Standard Bracket, w/Silencer)