Series: NCA1 (Standard), Mounting: D (MP2, Detachable Rear Clevis), Bore Size: 250 (2 1/2"), Stroke: 0600 (6"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: F (Flanged), Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: M (1m), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XB5 (Oversized Rod Cylinder)
Magnet: D (Built-in), Mounting: F (MF1, Front Flange), Bore Size: 250 (2 1/2"), Stroke: 0600 (6"), Air Cushion: Both Ends (Air Cushion), Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC6 (Stainless Steel Rod)
Magnet: None, Mounting: D (MP2, Detachable Rear Clevis), Bore Size: 250 (2 1/2"), Stroke: 0700 (7"), Air Cushion: Both Ends (Air Cushion), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC6 (Stainless Steel Rod)
Magnet: D (Built-in), Mounting: B (MX0, Basic), Bore Size: 250 (2 1/2"), Stroke: 0400 (4"), Air Cushion: Both Ends (Air Cushion), Adjustment Range: B (0 to 2"), Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.
Magnet: D (Built-in), Mounting: B (Through Hole), Overall Length: Standard, Bore Size: 250 (2 1/2"), Stroke: 200 (2"), Body Option: Standard (Rod End Female Thread), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: L (3m)
Cylinder Inner Diameter: D(φ): 32, Stroke: L(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead
Cylinder Inner Diameter: D(φ): 40, Stroke: L(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead
Cylinder Inner Diameter: D(φ): 50, Stroke: L(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead
Cylinder Inner Diameter: D(φ): 63, Stroke: L(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead
Cylinder Inner Diameter: D(φ): 80, Stroke: L(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead
Cylinder Inner Diameter: D(φ): 100, Stroke: L(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead
Series: NCA1 (Standard), Mounting: D (MP2, Detachable Rear Clevis), Bore Size: 250 (2 1/2"), Stroke: 0250 (2 1/2"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: IM (Intermediate Male, Threaded), Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.
Series: NCDA1 (Standard w/ Magnet), Mounting: D (MP2, Detachable Rear Clevis), Bore Size: 250 (2 1/2"), Stroke: 0400 (4"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.
Magnet: D (Built-in), Mounting: U (MT1, Rod Trunnion), Bore Size: 250 (2 1/2"), Stroke: 1400 (14"), Air Cushion: Both Ends (Air Cushion), Adjustment Range: B (0 to 2"), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC9 (Adjustable Stroke, Retraction Type)
Magnet: None, Mounting: D (MP2, Detachable Rear Clevis), Bore Size: 250 (2 1/2"), Stroke: 2000 (20"), Air Cushion: Both Ends (Air Cushion), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: X130US (Stainless Steel Parts: Piston Rod, Tie Rod, Tie Rod Nut, Cushion Valve Needle)
Magnet: D (Built-in), Mounting: B (Standard), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 200mm, Thread: TN (NPT), Stroke: 200mm
Areas where abrupt temperature changes may cause condensation. d. Areas where corrosive gas, flammable gas or other volatile flammable substances are stored. e. Areas where the product may be exposed to conductive powder such as iron powder or dust, oil mist, salt, organic solvent, machining chips, particles or cutting oil (including water and any liquids), etc. f.
Touching an emitter when it is electrified may result in electric shock or other accidents. d) Avoid using in a place in the presence of corrosive or explosive gas or where there is a volatile combustible. 3.
Filtration efficiency 99.9% Membrane FGH200 to 300 0.2 m EB ES X40 0.4 m Port size Element classification Note) 03 04 06 10 Rc3/8 Rc1/2 Rc3/4 Rc1 Element HEPO 2 Membrane Symbol J D Note) Refer to pages 70 to 73 for details about specifications, models, dimensions, etc. regarding the elements.
Magnet: None, Mounting: D (Double Clevis), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 180mm, Thread: Rc, Stroke: 300mm