These durable units have simple control systems and are easily serviced. *** These units are not available for use in the United States or Canada *** EC Directive compliant with CE marking for use in Europe, Asia and Oceania; 50 Hz operation ; Max. inlet air temperature: 122°F (50°C); Max. flow at rated conditions: 99 scfm 168m³/hr (ANR) @50°F (10°C) PDP; Connections: R/Rc threads are standard
These durable units have simple control systems and are easily serviced. *** These units are not available for use in the United States or Canada *** EC Directive compliant with CE marking for use in Europe, Asia and Oceania; 50 Hz operation ; Max. inlet air temperature: 122°F (50°C); Max. flow at rated conditions: 99 scfm 168m³/hr (ANR) @50°F (10°C) PDP; Connections: R/Rc threads are standard
Positive Y EX210-SAS2 4 out Negative Y EX210-SAS3 VQ2000/4000 4 out Positive Y EX210-SAS4 8 out Negative Y EX210-SAS5 8 out Positive Y EX210-SAS6 LonWorks SEMI, Echelon Special Order ** VQ, SX, SY & SV 16 out N Negative 16 out Positive N VQ, SX, SY & SV EX120/121/122-SMJ1 CC-Link CLPA & Mitsubishi 16 out Positive Y VQ2000/4000/5000 EX124 (U, D)-SMJ1 16 out Positive N SQ1000/2000, SZ3000/50
Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 63mm, Thread: Rc, Stroke: 50mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: F59--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire or Prewied Connector: -, Number: -
Magnet: Built-in, Mounting: Rear Flange, Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 50mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewied Connector: 3m, Number: -
Magnet: Built-in, Mounting: Rear Flange, Style: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 50mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewied Connector: 3m, Number: -
Magnet: Built-in, Mounting: Axial Foot, Style: Aluminum Tube, Bore Size: 63mm, Thread: Rc, Stroke: 50mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewied Connector: 3m, Number: -
Magnet: Built-in, Mounting: Axial Foot, Style: Aluminum Tube, Bore Size: 63mm, Thread: Rc, Stroke: 50mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: J59--Solid State, Gen. Purpose, 2 Wire, Lead Wire or Prewied Connector: 3m, Number: -
Magnet: Built-in, Mounting: Front Flange, Style: Aluminum Tube, Bore Size: 50mm, Thread: NPT, Stroke: 50mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: Y7BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewied Connector: 3m, Number: -
Magnet: Built-in, Mounting: Basic Style, Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 50mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)], Auto Switch: J59W--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewied Connector: 3m, Number: 1 pc.
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product, and replaced byCLA2G63-50-E
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Magnet: Built-in, Mounting: Basic Style, Style: Non-lube Rubber Bumper, Bore Size: 25mm, Thread: None, Stroke: 50mm, Option: None, Lock Style: Spring Lock (Exhaust Lock), Auto Switch: H7A2--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, 0.5M, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -
Magnet: Built-in, Mounting: Basic Style, Style: Non-lube Rubber Bumper, Bore Size: 32mm, Thread: None, Stroke: 50mm, Option: None, Lock Style: Spring Lock (Exhaust Lock), Auto Switch: H7B--Solid State, Gen. Purpose, 2 Wire, Lead Wire, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -