Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)
Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)
Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)
Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Output Specification: NPN Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: R1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Without Guide Operating Conditions Model : ML2B32 Load : 15N Speed , Va : 0.25m/s Pressure : 0.5MPa L1 : 0.05m L2 : 0.05m W W L1 L1 Loading Static Load Dynamic Load Side load due to W W3 Moment due to W M2 Moment due to we when stopping M3 V M1 V Static Load
Note 2) Value on option V (Non-leak, Vacuum).
Brown Brown Load Load Switch 1 Switch 1 Blue Blue Brown Brown Switch 2 Switch 2 Blue Blue Load voltage at ON = Power supply voltage Internal voltage drop x 2 pcs. = 24 V 4 V x 2 pcs. = 16 V Load voltage at OFF = Leakage current x 2 pcs. x Load impedance = 1 mA x 2 pcs. x 3 k = 6 V Example: Power supply is 24 VDC Internal voltage drop in switch is 4 V. Example: Load impedance is 3 k.
B + Stroke L M 0.2 A + Stroke E 25, 28 H thread effective depth C 2-Rc 1/8 2 x 4-OB Counterbore depth RB 2 x 4-OA effective depth RA Y Q F E J I 4-N through M 0.2 D W K B + Stroke L A + Stroke M 0.2 E Bore size (mm) Stroke range (mm) F A H B C D E OA I J K L M N OB Q RA W Y RB 10 10 to 40 69.5 M3 x 0.5 61.5 6 6 29 9 M4 x 0.7 38 5 8 20 3.5 6.5 39.5 7 5 4 16 10 to 60 80.5 M4 x 0.7 70.5 8
A + Stroke M 0.2 E 25, 28 H effective thread depth C 2-Rc 1/8 F Q Y 2 x 4-OA effective depth RA 2 x 4-OB Depth of counter bore RB J I 4-N through M 0.2 D W E K L B + Stroke M 0.2 A + Stroke E (mm) Bore size (mm) Stroke range (mm) OA A B C D E F H RB I J K L M N OB Q RA W Y M4 x 0.7 4 14.5 7 5 M3 x 0.5 10 to 40 39.5 31.5 6 6 29 5.5 10 38 5 8 20 3.5 6.5 M6 x 1.0 7 18 10 5 M4 x 0.7 10 to
0.2 A + Stroke M E 25, 30, 40 2 x P H effective thread depth C Q Y F 2 x 4 x OB Depth of counterbore RB 2 x 4 x OA effective depth RA J I 4 x N through 0.2 D W E M K B + Stroke L 0.2 A + Stroke M E (mm) Bore size (mm) P Stroke range (mm) RB Note) H OA A B C D E F W I Y J K L M N OB Q RA TN TF 10 39.5 M3 x 0.5 M4 x 0.7 10 to 40 31.5 6 6 ( 5.8) 29 5.5 38 4 5 5 8 20 3.5 6.5 14.5 7 16 44 M4
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 100 0.080 50 Load weight W (N) Cover range of MQQL (15) 10 MQQ28 5 MQQ25 MQQ20 1 MQQ16 0.5 MQQ10 0.3 50 (167) 100 500 300 MQQT: Standard type MQQL: Anti-lateral load type Maximum speed V (mm/s) Note) When a load is attached to the rod end, adjust the
OUT() DC(-) DC(+) PSE57-02-28 420 mA N.C. 500 (24 V ) 100 (12 V ) OUT() DC(-) -11No.PS-OMT0005CN-A (A/D ) () 20 2030 -12No.PS-OMT0005CN-A PSE575 PSE576 PSE577 02 MPa 05 MPa 010 MPa 5MPa 12.5MPa 30MPa 5%F.S.(25 ) PSE57-02 PSE57-02-28 DC1224 V1010% 10 mA 420 mA 15 V 1 k 500 (24 V ) 100 (12 V ) (25 ) 2.5F.S. 0.5F.S. 0.5F.S.(25 ) IP65 AC500V 1 100M(DC500 V) -1060 -2070 ()
Output Voltage output Note 5) 1 to 5 V within the flow rate range Analog Linearity: 2% F.S. or less, Allowable load resistance: 100 k or more specifications output Current output Note 6) 4 to 20 mA within the flow rate range Linearity: 2% F.S. or less, Allowable load resistance: 30 0 or less with 12 VDC, 600 or less with 24 VDC Power supply voltage 12 to 24 VDC (Ripple 10% or less) Current
Blue (DC(-)) 3 Blue (DC(-)) Other Settings Black (OUT: 4 to 20 mA) 4 Black (OUT: 1 to 5 V) Blue (LINE(-)) Auto shift [Default setting] Auto shift zero Mounting and Installation Check that the above preparation has been performed correctly, then part A shown should be pressed in by hand to make temporary connection.
In the case of diodes, the residual voltage is approximately 1 V. 5.