SMC Corporation of America
Elite Part Number Search
Search Results "LVM102R-5B-10-Q"

Symbol: Body Ported, 2 Port, N.O., Port 3 IN, Port 2 OUT, Tubing Type, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: 1000mm, CE Compliant: -

Symbol: Body Ported, 2 Port, N.O., Port 3 IN, Port 2 OUT, Tubing Type, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: 1000mm, CE Compliant: -

Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: 1000mm, CE Compliant: -

Symbol: Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: 1000mm, CE Compliant: -

Symbol: Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: None, Lead Wire Length: 1000mm, CE Compliant: -

Symbol: 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: Standard w/Power Saving Circuit, Voltage: 24VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material/Port Size/ Reverse Mounting Prevention Pin: w/o Sub-plate, Lead Wire Length: 1000mm, CE Compliant: -

Symbol: 3 Port, Universal, Function: Standard w/Power Saving Circuit, Voltage: 24VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material/Port Size/ Reverse Mounting Prevention Pin: w/o Sub-plate, Lead Wire Length: 1000mm, CE Compliant: -

Symbol: Base Mounted, 3 Port, Universal, Function: Standard, Voltage: 24VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material/Port Size: w/o Sub-plate, Lead Wire Length, Electrical Entry, Light/Surge Suppressor: 1000mm, CE Compliant: -

Symbol: Base Mounted, 3 Port, Universal, Function: Power-saving Circuit, Voltage: 24VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material/Port Size: w/o Sub-plate, Lead Wire Length, Electrical Entry, Light/Surge Suppressor: 1000mm, CE Compliant: -

Compatible Fluid: Air / Water / Chemical, Operating Environment: Standard, Type: Electromagnetic Type, Switching Type: Normally Closed, Body Material: Resin, Connection Type: Others, Plumbing Thread Nominal: -, Tube Diameter: -, Operating Temperature Range(°C): 0~50, Driving Type: Linear Motion Type, Orifice Diameter(Ø): 1.4, Insulation Class: B, Pipe opening type (details): Base Mounted

Compatible Fluid: Air / Water / Chemical, Operating Environment: Standard, Type: Electromagnetic Type, Switching Type: Universal, Body Material: Resin, Connection Type: Tube Connection, Plumbing Thread Nominal: -, Tube Diameter: φ2.8, Operating Temperature Range(°C): 0~50, Driving Type: Linear Motion Type, Orifice Diameter(Ø): 1.4, Insulation Class: B, Pipe opening type (details): Body Ported

Compatible Fluid: Air / Water / Chemical, Operating Environment: Standard, Type: Electromagnetic Type, Switching Type: Universal, Body Material: Resin, Connection Type: Others, Plumbing Thread Nominal: -, Tube Diameter: -, Operating Temperature Range(°C): 0~50, Driving Type: Linear Motion Type, Orifice Diameter(Ø): 1.4, Insulation Class: B, Pipe opening type (details): Base Mounted Type,

Compatible Fluid: Air / Water / Chemical, Operating Environment: Standard, Type: Electromagnetic Type, Switching Type: Normally Closed, Body Material: Resin, Connection Type: Others, Tube Diameter: -, Operating Temperature Range(°C): 0~50, Driving Type: Linear Motion Type, Orifice Diameter(Ø): 2, Insulation Class: B, Pipe opening type (details): Base Mounted Type, Voltage: 24 V DC, Power

Compatible Fluid: Air / Water / Chemical, Operating Environment: Standard, Type: Electromagnetic Type, Switching Type: Normally Closed, Body Material: Resin, Connection Type: Others, Tube Diameter: -, Operating Temperature Range(°C): 0~50, Driving Type: Linear Motion Type, Orifice Diameter(Ø): 2, Insulation Class: B, Pipe opening type (details): Base Mounted Type, Voltage: 24 V DC, Power

Connection Type: Screw⇔Screw Connection, Thread Nominal: 1/8, Connection screw: R, Thread-to-Thread Connection Shape: Bushing, Material: [Copper] C3604BD

Connection Type: Screw⇔Screw Connection, Connection screw: R, Thread-to-Thread Connection Shape: Bushing, Material: [Stainless Steel] 316 Stainless Steel

Q=226S P(P2+0.1013) Sonic flow : P1+0.10131.89(P2+0.1013) Q=113S(P1+0.1013) Q : Flow rate [ /min(ANR)] S : Effective area (mm2) P : Pressure differential (P1-P2) [MPa] P1 : Upstream pressure [MPa] P2 : Downstream pressure [MPa] When the air temperature is different, multiply the flow rate calculated with the above formula by the following coefficient for compensation. -20 1.08 -10 0 10 30

(0.45 MPa) 45 (0.45 MPa) 10 (0.45 MPa) 125 (0.45 MPa) 10 (0.45 MPa) Maximum ow rate [L/min] 120 16 130 16 180 16 Maximum pump head [m] 50 49 55 49 68 49 Settable pressure range5 [MPa] 0.10 to 0.50 0.10 to 0.49 0.10 to 0.55 0.10 to 0.49 0.10 to 0.68 0.10 to 0.49 Minimum operating ow rate6 [L/min] 20 2 25 2 40 2 Tank capacity [L] 42 7 42 7 60 7 Bypass circuit (With valve) Installed Electric

Note 10) The anchor bolt xing brackets (including 4 M10 bolts) are used for xing to wooden skids when packaging the thermo-chiller. No anchor bolt is included. 138 A

[10] Be sure to read this before handling the products.