Example; it takes approximately 8.8 seconds when the ullimate vacuum pressure is -89.kPa (25.9 in-Hg). -60 (23.21 6 -zo tzo et ,9 -oo 1rz r; 9.
cke1 ARlolo 60, AR20K ro AR2010 60. AR20K tJ 60K AB1010 40.
5 Port Solenoid Valve VQC1000/2000 Series Metal Seal Rubber Seal Connector Type Manifold IP67 enclosure compatible Power saving Power saving SV SYJ Standard: 0.4 W Standard: 0.4 W SZ RoHS (Reduced by 60% compared to current model) (Reduced by 60% compared to current model) VF VP4 High-pressure (1 MPa, Metal seal): 0.95 W High-pressure (1 MPa, Metal seal): 0.95 W VQ 1/2 VQ 4/5 VQC 1/2 VQC
1 2 100 VAC, Hz 200 VAC, Hz 50 60 50 60 3 4 5 6 110 VAC, Hz 220 VAC, Hz 24 VDC 12 VDC 7 240 VAC, Hz 50 60 Port size 50 60 Note 1) CE-compliant: Electrical entry is applicable only for the DIN terminal.
Dimensions . 46 47 48 50 52 52 53 54 54 55 55 56 57 58 60 60 60 61 62 63 65 65 65 66 66 67 67 68 69 69 70 70 71 72 73 75 75 75 77 77 78 78 78 79 80 82 84 84 84 85 86 87 87 88 89 90 Series AS * 2 * 0-D Speed Controller Adjustable by Flat Head Screwdriver: Standard Type Elbow Type \(Metal Body\) . Specifications. How to Order . Construction. Dimensions .
override Rated voltage Nil Push type 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz B Locking type (Slotted) C Locking type (Manual) 110 to 120 VAC, 50/60 Hz 4 Surge voltage suppressor Option 220 VAC, 50/60 Hz Indicator light 24 VDC 12 VDC 5 6 Light/Surge voltage suppressor E EZ Nil None 7 240 VAC, 50/60 Hz With light/surge voltage suppressor (Type E, T, D, or Y only) 9 Other Z Option S With
With light/surge voltage suppressor (Non-polar type) : SY100-30-A U Without lead wire (with connector and 2 of sockets only) Lead wire length Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Rated voltage 5 6 V S R 1 2 Electrical entry 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] G H L LN LO M MN
per minute 1 60 = x x Reference life cycles Cycles per minute 1 8 (daily operating time) Service life 1 60 = 1 8 50,000,000 50 x x 2083 days = 27 Process Pump Common Precautions 5 Be sure to read before handling.
Since a large quantity of liquid will be pumped out, use a suitable throttle in the discharge port if problems occur. 17-5-163 24 Series PB Performance Curves: Built-in Solenoid Valve Type/Air Operated Type Cycle 1 Hz Cycle 5 Hz Cycle 10 Hz 70 70 70 60 60 60 Total lifting range (m) Total lifting range (m) Total lifting range (m) 50 50 50 40 40 40 SUP = 0.7 MPa SUP = 0.7 MPa SUP = 0.7 MPa
Rated voltage Electrical entry 2 200 VAC 50/60 Hz 1 100 VAC 50/60 Hz G Grommet C Conduit 3 110 VAC 50/60 Hz D DIN terminal 4 220 VAC 50/60 Hz T Conduit terminal 5 24 VDC Refer to the table (1) given below for availability. 6 12 VDC 7 240 VAC 50/60 Hz 8 48 VAC 50/60 Hz 9 Other (Contact us for inquiry) Refer to the table (1) given below for availability.
75 20 20, 25, 32 25 22 19.5 40 32 13 10 17 10.5 10 45 4 60 75 26 32 22 19.5 40 32 13 12 17 10.5 11 45 4 60 75 26 40 24 21 52 41 16 14 22 13.5 12.5 50 5 66 36 82 32 MM N NA NN P S Z ZZ H1 H2 I K KA Bore (mm) 20 30 M20 x 1.5 1/8 37 200 146 M8 x 1.25 20 5 8 33.5 5 6 25 34.5 M26 x 1.5 1/8 41 204 146 M10 x 1.25 20 6 8 37.5 5.5 8 32 42.5 M26 x 1.5 1/8 41 217 159 M10 x 1.25 22 6 8 46.5 5.5 10
TF G 1/8 G 1/8 G 1/8 G 1/4 G 1/4 G 1/4 TN NPT 1/8 NPT 1/8 NPT 1/8 NPT 1/4 NPT 1/4 NPT 1/4 Nil M3 x 0.5 M5 x 0.8 M5 x 0.8 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/4 Rc 1/4 Rc 1/4 CY3B6 CY3B10 CY3B15 CY3B20 CY3B25 CY3B32 CY3B40 CY3B50 CY3B63 25 30 35 50 50 50 60 60 70 10 16 19 25 30 40 40 60 70 16 16 78 81 103 132 137 156 182 180 192 d CYP C H B H 4 4 8 8 10 B 8 14 26 32 41 C 9.2 16.2 30 37 47.3 d M6 x 1.0
75 20 20, 25, 32 25 22 19.5 40 32 13 10 17 10.5 10 45 4 60 75 26 32 22 19.5 40 32 13 12 17 10.5 11 45 4 60 75 26 40 24 21 52 41 16 14 22 13.5 12.5 50 5 66 36 82 32 MM N NA NN P S Z ZZ H1 H2 I K KA Bore (mm) 20 30 M20 x 1.5 1/8 37 200 146 M8 x 1.25 20 5 8 33.5 5 6 25 34.5 M26 x 1.5 1/8 41 204 146 M10 x 1.25 20 6 8 37.5 5.5 8 32 42.5 M26 x 1.5 1/8 41 217 159 M10 x 1.25 22 6 8 46.5 5.5 10
0 CE-compliant u Electrical entry y Rated voltage i Light/surge voltage suppressor CE-compliant 1 100 VAC, 50/60 Hz 2 200 VAC, 50/60 Hz 3 110 VAC, 50/60 Hz 4 220 VAC, 50/60 Hz 5 24 VDC 6 12 VDC Nil Q CE-compliant Nil None S With surge voltage suppressor Z With light/surge voltage suppressor G Grommet (Lead wire length 300 mm) H Grommet (Lead wire length 600 mm) L L type plug connector
Hz) 200 VAC (50/60 Hz) 24 VDC Other Air operated For the one without combined valve (0), solenoid valve does not come with.
51 43 34 26 17 85 IN 201 181 161 141 121 101 80 60 40 201 OUT 16 8 151 136 121 106 91 76 60 45 30 151 IN Bore size (mm) Mounting bracket part no.
80 Load (N) 20 40 60 80 Load (N) 20 40 60 100 Load (N) 12 12 12 L = 100 mm L = 100 mm L = 100 mm MXP12-15 MXP12-25 MXP12-15 MXP12-25 0.05 Table displacement amount (mm) Table displacement amount (mm) Table displacement amount (mm) 0.04 0.08 MXP12-15 MXP12-25 MXP12-15 MXP12-25 MXP12-15 MXP12-25 MXP12-15 MXP12-25 0.04 0.03 0.06 0.03 0.04 0.02 0.02 0.01 0.02 0.01 0 50 100 150 Load (N) 0 50
60 60 71.5 71.5 90.5 110 110 123 165 0.5 0.5 0.5 0.75 0.75 0.75 1 1 1.25 2 2 2 3 1 1.5 1 1.25 1.5 1.75 1.5 2 2.5 3 1.5 2 2 8 9 9 13 13 13 15 15 18 24 24 24 42 8 10 10 12 12 12 16 16 20 24 27 27 33 30.5 34 34 38 38 38 44.5 44.5 57.5 68 68 77 99 1146 Floating Joint: Standard Type JA Series Flange Type: JAF20 to JAF160 JAF20 to 40 x Center of sphere J J R JAF50 to 160 Center of sphere x R
Burst pressure Min. bending radius (mm) 100 15 20 30 60 75 75 60 48 36 24 25 13 20 to +60C (Water: 0 to 40 C) (No freezing) Operating temp. Nylon 12 Material Precautions How to Order Be sure to read before handling.
Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Other 1 2 3 4 5 6 9 Note) Option Note) Except large flow type.