This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CQ2-Z COMPACT CYLINDER, IE, 25MM CQ2-Z DBL-ACT AUTO-SW, 0.88184 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, NCQ2-Z COMPACT CYLINDER, PE, 63MM NCQ2-Z DBL-ACT AUTO-SW, 1.92335 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, NCQ2-Z COMPACT CYLINDER, HE, 20MM NCQ2-Z DBL-ACT AUTO-SW, .33000 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CQ2-Z COMPACT CYLINDER, NX, 50MM CQ2-Z DBL-ROD AUTO-SW, 1.98906 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, NCQ2-Z COMPACT CYLINDER, NE, 50MM NCQ2-Z DBL-ACT AUTO-SW, 1.47106 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, NCQ2-Z COMPACT CYLINDER, GE, 16MM NCQ2-Z DBL-ACT AUTO-SW, .22487 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, NCQ2-Z COMPACT CYLINDER, SE, 100MM NCQ2-Z DBL-ACT AUTO-S, 5.45820 lb
SMC has redesigned the NCQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions.? Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving?ease and safety of work.Compact, double acting, single rod, large bore , Bore size (mm): 125,?
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CQ2-Z COMPACT CYLINDER, PX, 63MM CQ2-Z DBL-ROD AUTO-SW, 2.42508 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CQ2-Z COMPACT CYLINDER, GX, 16MM CQ2-Z DBL-ROD AUTO-SW, .44092 lb
SMC has redesigned the NCQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions.? Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving?ease and safety of work.Compact, double acting, single rod, large bore , Bore size (mm): 125,?
CY D-A93 Less than 50 strokes CX D-M9 D-M9W Less than 55 strokes Less than 20 strokes MQ RHC RZQ D-X Individual -X 1037 Series REC Auto Switch Proper Mounting Position (Detection at Stroke End) and Its Mounting Height Reed auto switch Solid state auto switch D-M9 D-M9W D-A9 Hs Hs Auto switch Auto switch 8.5 8.5 A 22 A B B 16.5 16.5 22 (24.5) ( ): For D-A93 type D-C7, C80 D-G5NTL 8.5 12
Consult with SMC regarding water resistant types with the above model numbers. 2 1 m type lead wire is only applicable to D-A93. Solid state auto switches marked with are produced upon receipt of order.
D-M9/M/9W/M9A Less than 20 stroke Note 2) Less than 55 stroke Note 2) D-A90/A93 Less than 50 stroke Note 2) Note 2) Minimum stroke for auto switch mounting in styles other than those mentioned in Note 1. 12 Auto Switch Mounting Series CJ2Y Operating Range Auto Switch Mounting Brackets/Part No.
Note 4) ( ): Dimensions for D-A93. Specific Product Precautions Be sure to read this before handling. Mounting Caution Appropriate tightening torque 1. Observe the proper tightening torque in the right table in mounting.
Lead wire length (m) Auto switch model Electrical entry direction Load voltage Wiring (Output) Special function Electrical entry Indicator light Type 0.5 (Nil) 3 (L) Applicable load AC DC 12 V In-line A93 Reed auto switch 2-wire Grommet Yes Relay, PLC 100 V 24 V M9N 3-wire (NPN) 12 V Solid state auto switch Grommet Yes Relay, PLC 24 V M9B 2-wire 12 V Lead wire length symbols 0.5 mNil
Lead wire length (m) Load voltage Auto switch model Electrical entry direction Special function Electrical entry Indicator light Wiring (Output) 0.5 (Nil) 3 (L) Applicable load Type AC DC 12 V In-line 24 V 100 V 12 V 2-wire Reed auto switch Grommet Yes Relay, PLC A93 3-wire (NPN) M9N 24 V Solid state auto switch Grommet Yes Relay, PLC 12 V 2-wire M9B Lead wire length symbols
CY D-A93 Less than 50 strokes CX D-M9 D-M9W Less than 55 strokes Less than 20 strokes MQ RHC RZQ D-X Individual -X 1037 Series REC Auto Switch Proper Mounting Position (Detection at Stroke End) and Its Mounting Height Reed auto switch Solid state auto switch D-M9 D-M9W D-A9 Hs Hs Auto switch Auto switch 8.5 8.5 A 22 A B B 16.5 16.5 22 (24.5) ( ): For D-A93 type D-C7, C80 D-G5NTL 8.5 12
A water-resistant type cylinder is recommended for use in an environment which requires water resistance. 2 The 1 m lead wire is only applicable to the D-A93. Lead wire length symbols: 0.5 m Nil (Example) M9NW 3 m L (Example) M9NWL 1 m M (Example) M9NWM 5 m Z (Example) M9NWZ Solid state auto switches marked with are produced upon receipt of order.
IC circuit A96 A96V 5 V Yes 24 V Grommet A93V2 A93 A90 100 V Relay, PLC 2-wire 12 V A90V IC circuit No 100 V or less 1 Although it is possible to mount water resistant type auto switches, note that the rotary actuator itself is not of water resistant construction. 2 1 m type lead wire is only applicable to D-A93. Auto switches marked with a are produced upon receipt of orders.