SMC Corporation of America
Elite Part Number Search
Search Results "CY3R10-200-M9N"

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CY3R MAGNETICALLY COUPLED CYL, EE, 10MM CY3R DBL-ACT AUTO-SW, 1.27934 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CY3R MAGNETICALLY COUPLED CYL, EE, 10MM CY3R DBL-ACT AUTO-SW, 1.30439 lb

With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,

With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CY3R MAGNETICALLY COUPLED CYL, EE, 10MM CY3R DBL-ACT AUTO-SW, 1.46055 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CY3R MAGNETICALLY COUPLED CYL, EE, 10MM CY3R DBL-ACT AUTO-SW, 1.06882 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CY3R MAGNETICALLY COUPLED CYL, EC, 10MM CY3R ALL OTHERS(COMBO), 0.7165 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CY3R MAGNETICALLY COUPLED CYL, EE, 10MM CY3R DBL-ACT AUTO-SW, 1.46055 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CY3R MAGNETICALLY COUPLED CYL, EE, 10MM CY3R DBL-ACT AUTO-SW, 1.13537 lb

With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CY3R MAGNETICALLY COUPLED CYL, EE, 10MM CY3R DBL-ACT AUTO-SW, 1.12191 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CY3R MAGNETICALLY COUPLED CYL, EE, 10MM CY3R DBL-ACT AUTO-SW, 1.33145 lb

With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,

With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes, from

mm/s 0.5 to 200 mm/s 8 M8 x 1.25 14 M14 x 1.5 8 M8 x 1.25 14 M14 x 1.5 10 12 10 12 M10 x 1.25 M10 x 1.25 JIS Class 2 +1.4 0 mm 1/4 1/4 1/8 1/8 Vacuum suction port, Relief port Grease Particle generation grade M5 x 0.8 Fluorine grease Grade 2 Grade 1 2 l/min (ANR) Suction flow rate (Reference values) External dimensions and applicable auto switches are the same as 10-/11-CM2.

S Without connection port (For manifold) 00 Electrical entry Rated voltage 1 2 3 4 5 6 7 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz 24 VDC 12 VDC 240 VAC, 50/60 Hz CE-compliant G Grommet, Lead wire length 200 mm C Conduit D DIN terminal T Conduit terminal Terminal with indicator light TL DLDIN terminal with indicator light Note1) CE-compliant: Electorical entry

A parallel keyway is used instead of chamfer for size 40. +5 0 +5 0 +4 0 = Max. = 200 +4 0 = Max. = 110 End of rotation e g e n g a n r a r n n o o i t i a t a t End of rotation o t o R R Chamfer (Start of rotation) Chamfer (Start of rotation) (90) (45) A port B port A port B port Start of rotation is the position of the chamfer (keyway) when B port is pressurized.

Relay, PLC 100 V Reed switch Solid state switch PLC 100 V, 200 V Relay, PLC 12 V Yes Yes 24 V 2-wire Terminal conduit PLC 100 V, 200 V Relay, PLC DIN terminal Grommet Diagnostic indication (2-color indication) 3-wire (NPN) 3-wire (PNP) 5 V, 12 V 24 V IC circuit Grommet 100 V, 200 V 2-wire 12 V IC circuit 3-wire (NPN) 2-wire Terminal conduit 5 V, 12 V Relay, PLC 12 V 3-wire (NPN

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0.30 0.35 0.6 0.7 Outlet pressure MPa Outlet pressure MPa 0.5 0.25 0.4 0.20 0.3 0.15 0.2 0.10 0.1 0.05 0 0.00 0 50 100 150 200 0 50 100 150 200 250 300 Flow rate /min(ANR) Flow rate /min(ANR) Condition: Inlet pressure 0.7MPa Condition: Inlet pressure

Cutout window View A-A' Mounting Standard Stroke GK BP AG AB A AA AN B GD AH AI AJ AK AL AM AO AP BZ GC Bore size (mm) 20 25 32 40 Stroke range (mm) 92 3.5 9 9 75, 100, 125, 150, 200 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/8 94 73.5 13 11 54 75 32 28 134 150 108 140 M 8 135 110 4 9 9 104 86.5 16 15 62 88 37 29 160 176 125 165 M 8 160 75, 100, 125, 150, 200, 250, 300 110 4 9 9 104 86.5 16 15 62 88 37 30