(H) 00 64 h (H) (L) 44 - 32 32 1)700.00mm GW [OUT Data]Address.6 Address.9 0.01mm 700.00mm 7016 00011170h PLC 00 01 11 70 h 2)-700.00mm GW [OUT Data]Address.6 Address.9 Address.7 Address.6 01h 00h 15bit 8bit 7bit 0bit (H) 00 01 11 70 h (H) Address.9 Address.8 70h 11h 15bit 8bit 7bit 0bit (L) 00 01 11 70 h (L) 0.01mm 2 -700.00mm -7016 FFFEEE90h PLC FF FE EE 90 h Address.7 Address
AS1002F-02 AS1002F AS2002F Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) AS-F AS-F TMH ASD AS Number of needle rotations Number of needle rotations Number of needle rotations AS2052F AS3002F AS4002F AS-FE Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa KE Flow rate (L/
Model (Standard) Model Pressure range (1) VY1 Indication unit Connection thread Note MPa GP46-10-01 to 02 GP46-10-01 to 02L2 GP46-10-01 to 02L5 0 to 1.0 G 1 8 R MPa 1 4 R PPA Note 1) Do not apply pressure more than the maximum display pressure. This will cause a malfunction. Be sure to read the precautions in page 14-11-15 for selection and installation.
Type AS1200-M3 Direct cylinder elbow type 2 Bore size JIS Symbol Direct cylinder flat elbow type 4 Symbol Bore size Applicable series Control type AS1200-M3 AS1400-M3 M3 M3 x 0.5 Meter-out Meter-in 0 1 AS120-M5 AS120-U10/32 AS220-01 AS220-02 AS320-03 AS420-04 M5 x 0.8 10-32UNF 1/8 1/4 3/8 1/2 M5 U10/32 01 02 03 04 P.15-11-3 Thread type Cylinder side R Tube side Rc Symbol Metric thread (M3
AS1201F-M5, AS1211F-M5 AS2201F-01, AS2211F-01 AS2201F-02, AS2211F-02 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 100 Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) 80 60 40 20 0 0 2 4 6 8 Number of needle rotations Number of needle rotations Number of needle rotations AS3201F, AS3211F AS4201F, AS4211F Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Flow rate (
(When reversed output is selected, the sub display (left) shows [n1L/n2L] and [n1H/n2H].) 16000 L/min 12000 L/min 20 L/min 6000 L/min Additional range 3 Blue DC(-) DC(-) WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury.
PF2A ZS-36-A1 ZS-36-A2 ZS-36-A3 ZS-36-A4 ZS-36-A5 2 L-type brackets, 2 mounting screws M3 x 15L For 1 station (for single unit) For 2 stations 2 L-type brackets, 2 mounting screws M3 x 25L PF2W For 3 stations 2 L-type brackets, 2 mounting screws M3 x 35L For 4 stations 2 L-type brackets, 2 mounting screws M3 x 45L PF2D For 5 stations 2 L-type brackets, 2 mounting screws M3 x 55L IF 951
Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)
Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)
Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)
Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)
Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)
Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8)
Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Output Specification: NPN Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Pressure Range: -0.1 to 1 MPa, Piping: URJ1/4, Rear Ported, Input/Output: PNP Open Collector 1 Output, Option 1: Initial Value PSI, Option 2: -, Option 3: -, X Options: -