SMC Corporation of America
Elite Part Number Search
Search Results "PF2D520-13-1"

IO-Link enabled sensor for wet or dry environments, with an IP65 rating; 3 setting modes: 3-step, simple, function selection; 5 pressure units: MPa, kPa, kgf/cm2, bar, psi; IO-Link mode: 16-bit digital process data; SIO mode: 1 switch output (selectable NPN or PNP); Port sizes: M5 (female), 1/8 Rc (male), 1/8 NPT (male); Bracket or panel mounting options

IO-Link enabled sensor for wet or dry environments, with an IP65 rating; 3 setting modes: 3-step, simple, function selection; 7 displayable units: MPa, kPa, kgf/cm2, bar, psi, inHg, mmHg; IO-Link mode: 16-bit digital process data; SIO mode: 1 switch output (selectable NPN or PNP); Port sizes: M5 (female), 1/8 Rc (male), 1/8 NPT (male); Bracket or panel mounting options

IO-Link enabled sensor for wet or dry environments, with an IP65 rating; 3 setting modes: 3-step, simple, function selection; 5 pressure units: MPa, kPa, kgf/cm2, bar, psi; IO-Link mode: 16-bit digital process data; SIO mode: 1 switch output (selectable NPN or PNP); Port sizes: M5 (female), 1/8 Rc (male), 1/8 NPT (male); Bracket or panel mounting options

IO-Link enabled sensor for wet or dry environments, with an IP65 rating; 3 setting modes: 3-step, simple, function selection; 5 pressure units: MPa, kPa, kgf/cm2, bar, psi; IO-Link mode: 16-bit digital process data; SIO mode: 1 switch output (selectable NPN or PNP); Port sizes: M5 (female), 1/8 Rc (male), 1/8 NPT (male); Bracket mounting options

IO-Link enabled sensor for wet or dry environments, with an IP65 rating; 3 setting modes: 3-step, simple, function selection; 5 pressure units: MPa, kPa, kgf/cm2, bar, psi; IO-Link mode: 16-bit digital process data; SIO mode: 1 switch output (selectable NPN or PNP); Port sizes: M5 (female), 1/8 Rc (male), 1/8 NPT (male); Bracket mounting options

IO-Link enabled sensor for wet or dusty environments, with an IP65 rating; 3 setting modes: 3-step, simple, function selection; 7 displayable units: MPa, kPa, kgf/cm2, bar, psi, inHg, mmHg; 1 switch ouput (selectable NPN or PNP); IO-Link mode: 16-bit digital process data; • SIO mode: 1 switch output (selectable NPN or PNP); M5 female, R1/8 male or 1/8 NPT piping port; Bracket or panel mounting

IO-Link enabled sensor for wet or dusty environments, with an IP65 rating; 3 setting modes: 3-step, simple, function selection; 7 displayable units: MPa, kPa, kgf/cm2, bar, psi, inHg, mmHg; 1 switch ouput (selectable NPN or PNP); IO-Link mode: 16-bit digital process data; • SIO mode: 1 switch output (selectable NPN or PNP); M5 female, R1/8 male or 1/8 NPT piping port; Bracket or panel mounting

Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") HIGH PURITY CHEMICAL VALVE

Body Size: 40A, Thread: N (NPT), Port Size: 04 (1/2), Option: Standard, Attachment: Standard, Semi-Standard 1: 13 ( 1 + 3), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)

Stations: 13 Stations, Port Size: N7T (1/4" One-touch Fitting), Electrical Entry Direction: U (Plug-in L Kit U Side), Cable Length: 1 (1.5m Cable), Control Unit: None, Release Valve Rated Voltage: w/o Air Release Valve, Option 1: SB (Built-in Silencer, Direct Exhaust from Both Sides)

IO-Link enabled sensor for wet or dry environments, with an IP65 rating; 3 setting modes: 3-step, simple, function selection; 5 pressure units: MPa, kPa, kgf/cm2, bar, psi; IO-Link mode: 16-bit digital process data; SIO mode: 1 switch output (selectable NPN or PNP); Port sizes: M5 (female), 1/8 Rc (male), 1/8 NPT (male); Bracket or panel mounting options

IO-Link enabled sensor for wet or dry environments, with an IP65 rating; 3 setting modes: 3-step, simple, function selection; 7 displayable units: MPa, kPa, kgf/cm2, bar, psi, inHg, mmHg; IO-Link mode: 16-bit digital process data; SIO mode: 1 switch output (selectable NPN or PNP); Port sizes: M5 (female), 1/8 Rc (male), 1/8 NPT (male); Bracket or panel mounting options

Size Combination: 13 (Size 4, Thread 1/2", Tubing Size 1/2"x3/8"), Thread Type: Rc, Nut Material / Packaging: 1 (PFA / Standard Packaging Equiv. to Class M5.5)

Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") HIGH PURITY CHEMICAL VALVE

Body Class: 4 (Orifice Dia. ø10), Valve Type: 0 (N.C.), Applicable Tubing Size: 13 (1/2" x 3/8"), Pilot Port Thread Type: N (NPT 1/8), Pilot Port Position: None (Position 1), Material: FN (Body: PFA; End Plate: PVDF; Diaphragm: PTFE; Seal, Buffer: EPDM)

.: 13 (1/2), Pilot Port Thread: N (NPT 1/8), Pilot Port Position: None (Position 1), Material: FN (Body: PFA; End Plate: PVDF; Diaphragm: PTFE; Seal, Buffer: EPDM)

Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") HIGH PURITY CHEMICAL VALVE

Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") HIGH PURITY CHEMICAL VALVE