Cooling Capacity: 250 (25kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: M (Applicable to DI Water Piping)
Material: E (Aluminum Cover, SPCD Case, NBR Gasket/O-ring, Nylon/Fluororesin Seal), Element Length: A (ℓ250), Port Size: 04 (1/2 Rc), Element Type: M (Micromesh, Stainless Steel 304/Epoxy Material), Nominal Filtration Accuracy: 5 μm, Element Seal Material: N (NBR), Accessory: B (Bracket)
Material: C (Aluminum Cover, SPCD Case, NBR Gasket/O-ring, Nylon Seal), Element Length: A (ℓ250), Port Size: 04 (1/2 Rc), Element Type: B (Sintered Metal, Bronze Material), Nominal Filtration Accuracy: 2 μm, Element Seal Material: N (NBR)
Magnet: None, Mounting: C (MP4, Single Detachable Rear Clevis), Bore Size: 250 (2 1/2"), Stroke: 0800 (8"), Air Cushion: Both Ends (Air Cushion), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC6 (Stainless Steel Rod)
Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 14 (1 1/2), Output Specification: B (OUT1: PNP; OUT2: PNP), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)
Magnet: None, Mounting: B (MX0, Basic), Bore Size: 250 (2 1/2"), Stroke: 1000 (10"), Air Cushion: Both Ends (Air Cushion), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC22 (Viton Seals)
NC1A: NC1A, Option: W (Double Rod), Bore: 250, PS: PS, Special Options: XB7 (Low Temperature)
Magnet: None, Mounting: D (MP2, Detachable Rear Clevis), Bore Size: 250 (2 1/2"), Stroke: 0700 (7"), Air Cushion: Both Ends (Air Cushion), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC6 (Stainless Steel Rod)
Magnet: D (Built-in), Mounting: B (MX0, Basic), Bore Size: 250 (2 1/2"), Stroke: 0400 (4"), Air Cushion: Both Ends (Air Cushion), Adjustment Range: B (0 to 2"), Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.
Series: NCDA1 (Standard w/ Magnet), Mounting: G (MF2, Rear Flange), Bore Size: 250 (2 1/2"), Stroke: 0050 (1/2"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: SF (Short Female, Threaded), Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.
Magnet: D (Built-in), Mounting: B (Through Hole), Overall Length: Standard, Bore Size: 250 (2 1/2"), Stroke: 200 (2"), Body Option: Standard (Rod End Female Thread), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: L (3m)
Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 12 (1 1/4), Output Specification/Temperature Sensor: L (Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: None)
Series: NCDA1 (Standard w/ Magnet), Mounting: B (MX0, Basic), Bore Size: 250 (2 1/2"), Stroke: 1000 (10")
Series: NCDA1 (Standard w/ Magnet), Mounting: B (MX0, Basic), Bore Size: 250 (2 1/2"), Stroke: 0600 (6")
Series: NCDA1 (Standard w/ Magnet), Mounting: F (MF1, Front Flange), Bore Size: 250 (2 1/2"), Stroke: 0800 (8"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: IM (Intermediate Male, Threaded)
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Specification: -, Port thread type: Rc, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Specification: -, Port thread type: NPT, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 140, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Specification: -, Port thread type: Rc, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 140, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Specification: -, Port thread type: NPT, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Specification: -, Port thread type: Rc, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches