Material Bronze Note Clear coated q Description Cover assembly Body Aluminum alloy Brass Platinum silver painted PTFE, EPR, FKM w e Plate assembly Valve element Piston assembly Return spring Second plate assembly r Brass, PTFE t Aluminum alloy y Piano wire u Aluminum alloy Body option S is made of stainless steel. 17-4-42
(A) 4 (B) 2 (A) 4 (B) 2 0.6 SS5YJA5 The remainder of the manifold part number is called out the same as an SS5YJ5 0.5 1 (P) 3 (R) 1 (P) 3 (R) Pilot pressure range 3 position pressure center 0.4 (A) 4 (B) 2 Specify the part numbers for the valve(s), blank plate assembly and manifold base. 0.3
VQ VQ4 VQZ VQD VZS VFS VS VS7 1.13-9 Series VQD1000 Dimensions Plug lead unit manifold(VV4QD12-l) Lead wire length: 300mm 4-Rc(PT)1/8 (P, R port) Light 2-4.5 (Mounting hole) 57 50.5 5.3 5.3 52 0.6 1 3 P R 1 3 R P 30 17 6.5 15 7 10 P=11 0.5 0.5 2n-M5 (A, B port) L2 35 4 M5: M5 thread L1 38 42 M plug connector (M) Station 1 2 3 4 5 n D side U side Direct manual override (Non-locking) 24 15
Pin description 1 DC(+) 2 NC/Analog output A (44.2) 3 DC() 4 OUT (mm) A B Output specification Output for monitor unit only 42 62 Output for monitor unit + Analog output 52 72 Flow direction 309 B Series PF2W Dimensions: Remote Type Sensor Unit For Water PF2W511-(N)B 148 32 80 70 58 46 45 36 2 x Port size 45 2 4 x 5.5 (44.2) A (mm) A B Output specifications Output for monitor unit only 63
QA F 13 KA KB Tubing O.D. 6 8 QB Stroke Q QU 32 6 7.5 20 13 38 60.5 40 6 8 24.5 13 42 68 50 8 9.5 26 16 50 82 29 1.8 Stroke 20 QW Tubing O.D. QA F 13 Tubing O.D. 6 QU 8 QB Stroke Q 29 1.8 Stroke 20 QW 32 to 50 20 Tubing O.D.
Dual 3-port valve S07 A B C6 0.58 0.39 0.16 0.67 0.37 0.18 25 or less 49 2-position Single S0712 0.51 0.40 0.15 0.64 0.33 0.15 22 or less 34 Double S0722 0.51 0.40 0.15 0.64 0.33 0.15 10 or less 42 Manifold 3-pos. Bar Base 3-position closed center S0732 0.54 0.37 0.10 0.46 0.38 0.08 45 or less 42 Page 745 4-pos.
Guide Rod Type Compact Cylinder CQM Series (Slide bearing) Deflection Compact and Space-saving Height/at 10 mm stroke [mm] Depth Width Bore size MXZ MXH MGP CQM 12 44 56.51 53 41.5 16 45 66 59 41.5 20 49.5 78 69 52 25 54 75.5 55.5 Workpiece mounting hole 1 Compared with bore size of 10 Width [mm] Bore size MXZ MXH MGP CQM Height 12 23 201 26 25 16 26 25 30 29 20 30 32 36 36 25 33.5 42
-X555 P1 Soft start-up valve : OFF Valve 1, Valve 2: ON Soft start-up valve 0 Time 1 3(R) 3(R) Safety Standard ISO13849-1 Certied 3 Port Solenoid Valve/Residual Pressure Release Valve with Detection of Main Valve Position Series VP/VG Standards and Enclosure Standards Category Machinery Directive CE cUL EN ISO13849-1: 2008 EN ISO13849-2: 2008 EN ISO4414: 2010 EN983: 1996 + A1: 2008 2006/42
SS5YJA5-42-03-01 1 set SYJA5140 1 set SYJA5240 1 set SYJ5000-21-1A 1 set 4(A) (B)2 4(A) (B)2 1 (P) (R)3 1 (P) (R)3 3 position pressure center The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc. 4(A) (B)2 1 (P) (R)3 Caution Be sure to read this before handling the products.
Model Weight (g) N L A Q M D (mm) 4 6 8 10 12 KQGT04-00 KQGT06-00 KQGT08-00 KQGT10-00 KQGT12-00 10.6 20.6 28.7 4.1 18 6.4 28 3.2 13 22.4 31.4 4.9 18.8 10.6 42 M N D L A 15 25.5 36.3 6.1 20.9 25.6 57 D 4.2 18 28.6 40.6 7.1 23 40 95 Q 20.8 31.4 44.5 8.1 24.8 57.4 129 M M L L Note 1) D is maximum diameter.
mA), 1.5 W DC (63 mA) , 0.5 W DC (21 mA) 24 VDC (3) (4) 3 position exhaust center 1 W DC (83 mA), 1.5 W DC (125 mA) , 0.5 W DC (42 mA) 12 VDC Power consumption (Current) Inrush 0.5 VA (5 mA), Holding 0.5 VA (5 mA) 100 VAC Start-up 0.55 VA (5 mA), Holding 0.55 VA (7.5 mA) 110 VAC Inrush 1.0 VA(5 mA), Holding 1.0 VA (5 mA) 200 VAC Inrush 1.1 VA (5 mA), Holding 1.1 VA (5 mA) 220 VAC 3 position
Outlet Air Temperature 50C 70C 100C Inlet air temperature (C) Correction factor Air flow (l/min (ANR)) Model 35.5 42.5 47.5 36 42.5 44 38.5 42.5 45 39 43 45 35 40 44 35.5 40 42 37 40 41.5 38 40 42 34.5 38 40 33 36.5 38 34 36 37 34 35 36 500 1000 1500 1000 2200 3000 2000 3300 4000 4000 5700 7000 HAA7 Air inlet Air outlet Air cooled style after cooler HAA15 HAA22 Auto-drain HAA37 Min.
Setting 22 Default settings 22 F0 Unit selection function 23 F1 Setting of OUT1 24 F2 Setting of OUT2 27 F3 Operating fluid 28 F4 Reference condition 29 F5 Response time 30 F6 Display mode 31 F7 External input 32 F8 Display resolution 35 F9 Auto-preset 36 F10 Accumulated value hold 38 F11 Analogue output filter 39 F12 Power saving mode 40 F13 Security code 41 F98 Setting of all functions 42
Project will be loaded. -42- 6.9 Acquisition of motion waveform with graph monitor With the setup software (MR Configurator2TM: LEC-MRC2E) monitor graph function, the motion waveform during electric actuator operation can be obtained as described below. Click Monitor Graph of Setup software to display Graph window.
It is necessary to set it on the PLC side according to the kind of PLC. 6.2 The recommended value of the parameter [LEJ] LEJS40 LEJS63 LEJB40 LEJB63 Lead symbol H A B H A B T Series Lead 24 16 8 30 20 10 27 42 Parameter *1,*2 Para.
(1) Parallel I/O forced output . 42 4.8.
No.SFOD-OMT0011CN-A (4 ) // JXC-W1 (JXC3 Series) 1. . 3 2. . 5 2.1 . 5 2.2 . 5 2.3 . 5 3. . 6 3.1 . 6 (1) . 6 (2) . 6 3.2 . 6 (1) . 6 (2) . 6 (3) . 8 4. . 9 4.1 . 9 (1) . 9 (2) . 16 (3) . 19 (4) . 22 (5) . 23 (6) . 24 (7) . 26 4.2 . 28 (1) . 28 (2) . 31 (3) . 32 4.3 . 33 (1) . 33 (2) . 35 4.4 . 36 4.5 . 36 4.6 . 39 (1) . 39 (2) JOG . 40 (3) 1 . 40 4.7 . 42
ZQ-OM01401-B / / ZQA No.ZQ-OM01401-B 2 1. 5 2. 9 3. 11 3.1. 11 3.2. 12 3.3. 13 3.4. 14 3.5. 16 4. 17 5. 19 6. 20 7. 21 8. 28 9. 32 10. 35 11. 37 12. 40 13. 42 1 - No.ZQ-OM01401-B /ZQA *1) *2) (ISO/IEC)(JIS) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety of machinery
For details of each setting, refer to page 17 to 42 of this manual. The Pressure switch is compulsory turned off for 1 seconds after power supplied. For 4 seconds after supplying power, the measurement output is turned off. Maintenance Turn off the power supply, stop the supplied air, exhaust the residual pressure and verify the release of air before performing maintenance.
x 42 ) Bellows type for N Without flange ZP3P 10 C S Flat with ribs M With mesh attachment 10 Silicone rubber (White) 2 film packaging 13 13 B Bellows U Urethane rubber 3 Only applicable to the cup workpieces Nil Without cup 16 16 UT Thin flat F FKM form JT.