Magnet: Built-in, Mounting: Foot, Type: Standard, Bore Size: 20mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 5mm, Body Option: -, Auto Switch Groove: -, Mounting Bolt: -, Rod End Bracket: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Mounting Threads: -, Rod Type: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.07~1.0, Support bracket: Threaded, Port thread type: M5, Body Options:
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Threaded, Port thread type: M5, Body Options:
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Threaded, Port thread type: Rc, Body Options:
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.07~1.0, Support bracket: Through hole, Port thread type: M5, Body Options
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.07~1.0, Support bracket: Through hole, Port thread type: M5, Body Options
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Through hole, Port thread type: M5, Body Options
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Through hole, Port thread type: M5, Body Options
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Through hole, Port thread type: Rc, Body Options
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, SGL ACT, SPR RET, ACTUATOR, CQS COMPACT CYLINDER, FS, 12MM CQS SPRING RETURN, .00000 lb, SeriesDescriptionModelActionNoteVol. no. (for std model)CQSCompact cylinderCQSDouble acting, Single rodExcept with rubber bumper777
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, SGL ACT, SPR EXT, ACTUATOR, CQS COMPACT CYLINDER, FT, 12MM CQS SPRING EXTEND, .23148 lb, SeriesDescriptionModelActionNoteVol. no. (for std model)CQSCompact cylinderCQSDouble acting, Single rodExcept with rubber bumper777
Nominal Size: 100mm, Stroke: 100mm, Size: S (Small Flow Style), Control Valve: 3 (Speed Controller For Minimal Flow (CCVS Only)), Combination Valve: 1 (Stop Valve/Skip Valve), Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal)
Size: 5 [ø32(ø22)], Valve Type: 4 [NC (Operating Pressure 1MPa)], Sealant: A (NBR seal), Thread: N (NPT), Port Size: 32A (1 1/4), Voltage: 5 (24VDC), Lead Wire: D (DIN Terminal)
Magnet: D (Built-in), Mounting: T (Trunnion), Bore Size: Ø10 mm, Stroke: 5 mm, Rod End Thread: With Thread, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in Magnet), VAC Side Tube/Rod End Shape: C (Cap Piping/Male Thread), Bore Size: 25mm, Port Thread: M5x0.8 (Bore 10, 16, 20, 25), Rc1/8 (Bore 32), Stroke: 5mm, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: L (3m)
Function: 1 (2 Position Single), Body Option: 10 (Non Plug-in Type Sub-plate, Standard), Pilot Type: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 10 (Sub-plate Plug-in Terminal 1, Non Plug-in Standard 1)
Function: 2 (2 Position Double), Body Option: 10 (Non Plug-in Type Sub-plate, Standard), Pilot Type: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: w/o Sub-plate, Thread: Rc (Or None in Case of w/o Subplate), CE Compliant: Q (CE-compliant)
Function: 2 (2 Position Double), Body Option: 10 (Non Plug-in Type Sub-plate, Standard), Pilot Type: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 10 (Sub-plate Plug-in Terminal 1, Non Plug-in Standard 1)
Function: 2 (2 Position Double), Body Option: 10 (Non Plug-in Type Sub-plate, Standard), Pilot Type: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 10 (Sub-plate Plug-in Terminal 1, Non Plug-in Standard 1), Thread: N (NPT)