SMC Corporation of America
Elite Part Number Search
Search Results "CS2D160-200"

VAC 50 Hz, 3-phase 200 to 208 VAC 60 Hz Allowable voltage fluctuation ?

0.10.45/0.65 (at 20 l/min)20Approx. 15Approx. 16Rc 3/4Stainless steel, EPDM, Copper brazing (Heat exchanger), PPS, Silicone, Fluororesin10 to 250.3 to 0.713/14Rc 1/2Stainless steel, EPDM, Copper brazing (Heat exchanger), Silicone, Brass3-phase 200 VAC 50 Hz, 3-phase 200 to 208 VAC 60 Hz Allowable voltage fluctuation ?

VAC 50 Hz, 3-phase 200 to 208 VAC 60 Hz Allowable voltage fluctuation ?

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN

When the LEF is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein..Body size: 16, 25, 32, 40, Ball screw drive , Applicable stroke range: 100, 200, 300, 400, 500, 600, 700, 800, 900, 1000, 2 types of motors: servo motor ball screw drive or step motor belt drive , Controller mounting: screw or DIN

Operating pressure range: 0.2 - 1MPa, Coil rated voltage: 12, 24VDC; 100, 110 to 120, 200, 220VAC, Allowable voltage fluctuation: -15% to +10% of rated voltage, Ambient and fluid temperature: 0 to 60C, Electrical entry: grommet, type D DIN connector, type Y DIN connector, VALVE, SOFT START 3/4, VALVE, AV SOFT START UP BODY PORT, 1A, AV OTHER SIZE RATING, 3.93242 lb, ModelPort sizeProof

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: M (Applicable to Deionized Water Piping)

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: F (G, w/Rc-G Conversion Fitting), Power Supply: 20 (3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz), Option: SW (Conforming to CE/UL Standards + SI Unit Only)

Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: F [G (w/Rc-G Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: J (w/Automatic Fluid Fill Function)

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: BM (B + M)

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: BM (B + M)

This model is compatible with single phase 200 VAC 50/60Hz power. Air cooled only, without heating feature ; Cooling capacities: 1.2 kW, 1.6 kW, 2.2 kW (at 60Hz) ; Temperature range setting: 10 to 30°C ; Temperature stability: ±2°C ; Power supply requirement: single phase 200 VAC, 50/60Hz ; Standards: RoHS ; Circulating fluid: Tap water or 15% ethylene glycol solution

Cooling capacities: 10.5 kW, 15.7 kW, 20.5 kW, 25 kW, 28 Kw ; Temperature range setting: 5 to 35°C ; Temperature stability: ±0.1°C ; Power supply requirement: 3-phase 200 VAC, 50Hz or 3-phase 200 ~ 230 VAC, 60Hz ; Waterproof specification: IPX4 ; Circulating fluid: Tap or deionized water, or 15% ethylene glycol solution

Cooling capacities: 11.5 kW, 15.7 kW, 20.6 kW, 24 kW ; Temperature range setting: 5 to 35°C ; Temperature stability: ±0.1°C ; Power supply requirement: 3-phase 200 VAC, 50Hz or 3-phase 200 ~ 230 VAC, 60Hz ; Waterproof specification: IPX4 ; Circulating fluid: Tap or deionized water, or 15% ethylene glycol solution

Cooling capacities: 2 kW, 8 kW, 15 kW, 30 kW ; Temperature range setting: 20 to 90°C ; Temperature stability: ±0.3°C ; Power supply requirement: 3-phase 200 VAC / 50Hz or 3-phase 200~208 VAC / 60Hz ; Circulating fluid: Clear or deionized water, fluorinated liquid, or 60% ethylene glycol solution ; Standards: UL, CE, SEMI (S2-0703, S8-1103, F47-0200), SEMATECH (S2-93, S8-95)

Fluid fill and drain ports (800W, 1kW) on the front; Mechanical sealless magnet pump eliminates shaft seal leaks; Cooling/Heating capacities: 200W/600W, 400W/1kW, 510W/1.2kW, 800W/1.4kW, 1kW/2kW; Temperture stability: ±0.03°C or Better depending on load stability; Power supply requirement: 100 ~ 240 VAC (200-800W) or 200~240 VAC (1kW) (50/60Hz); Circulating Fluid: water or 20% ethylene glycol

Cooling capacities: 10 kW or 15 kW ; Temperature range setting: 5 to 35°C ; Temperture stability: ±1.0°C ; Power supply requirement: 3-phase 200 VAC 50 Hz or 200~230 VAC 60 Hz ; Waterproof specification: IPX4 ; Circulating fluid: Tap or deionized water, or 15% ethylene glycol solution