Metric System (g) = 105.5 meters per sec. per sec NewtonMeters KilopondMeters Foot-lbs Inch-lbs 3 3 1.020 x 10 -1 7.376 x 10 -1 8.851 1 3 7.233 3 3 1 3 86.80 0.01 3 1.382 x 10 -1 1 3 12 3 1.356 1.130 x 10 -1 1.52 x 10 -2 8.333 x 10 -2 1 3 Length (Linear Measurement) Meter Centimeter Kilometer Mile Inch Foot 3 100 3 1x10 4 6.214x10 -4 39.370 3 3.281 3 1 3 1 3 1x10 5 6.214x10 -6 3.937x10 -1
range Usable range 5 5 5 1 0 1 2 3 4 5 6 1 0 1 2 3 4 5 6 1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 7 8 9 10 11 7 8 9 10 1112 13 14 15 Distance from cylinder shaft center L0 (cm) Distance from cylinder shaft center L0 (cm) Distance from cylinder shaft center L0 (cm) 100 REBR32 REBR25 10 REBR15 1 0.1 100 200 300 400 600 500 Maximum speed U (mm/s) 62 Series
[C] 5 10 15 20 25 30 35 Circulating fluid temperature [C] HRS090-W-20/40 (50 Hz) HRS090-W-20/40 (60 Hz) 14 12 12 10 Facility water temperature 32C Facility water temperature 32C Cooling capacity [kW] Cooling capacity [kW] 10 8 8 6 Facility water temperature 40C Facility water temperature 40C 6 4 4 2 2 0 0 5 10 15 20 25 30 35 Circulating fluid temperature [C] 5 10 15 20 25 30 35 Circulating
Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 3 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 4 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Low level in tank 1 High circulating fluid discharge temp. 2 Circulating fluid discharge temp. rise 3 Circulating fluid discharge
Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 3 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 4 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Low level in tank 1 High circulating fluid discharge temp. 2 Circulating fluid discharge temp. rise 3 Circulating fluid discharge
Z 66 76 94 107 117 130 148 176 188 M 3.5 4 5 5 6 7 8 10 10 MM M3 x 0.5 M3 x 0.5 M4 x 0.7 M4 x 0.7 M5 x 0.8 M6 x 1 M6 x 1 M8 x 1.25 M8 x 1.25 N PW 19 26 32 38 43 54 64 82 94 Q 60 68 84 95 105 116 134 159 171 QW 10 14 18 17 20 26 34 48 60 T 14.5 17.5 19 20.5 21.5 24 26 30 32 TC 10.5 14 17 20 22.5 28 33 42 48 Model 12-CY3R6 12-CY3R10 12-CY3R15 12-CY3R20 12-CY3R25 12-CY3R32 12-CY3R40 12-CY3R50
17 140 14.5 10 17 160 13 10 17 180 14 10 17 200 14.5 10 17 D-Z7/Z80 D-A3/A44/A5/A6 D-A59W D-Y59/Y69/Y7P/Y7PV D-Y7W/Y7WV D-Y7BAL D-F5/J5/F5W/J59W D-F5BAL/F5NTL/F59F D-G39/K39 12 13 7 7.5 8 6 6 7 7 7 6 6 5 5.5 5 11 11 10 10 10 Since this is a guideline including hysteresis, not meant to be guaranteed.
: 2 to 10 stations U side: 2 to 10 stations Nil Standard length (Specify a longer rail than the standard length.)
EXW1 EXW1 Up to 100 m V.1.0 / V.2.0 Available *1 EXW1 EXW1+EX600 *2 V.1.0 Not available EXW1 EX600 Up to 10 m V.1.0 Not available EX600 EXW1 Up to 10 m V.1.0 Not available Available *3 EX600 EXW1+EX600 Up to 10 m V.1.0 Not available Available *3 EX600 EX600 Up to 10 m V.1.0 Not available Available *1 Available in protocol V.2.0. *2 Up to 100 m between an EXW1-series Base and Remote, and up
Problem Problem possible causes Investigation method Countermeasures Check that the power supply voltage is within the range 12 to 24 VDC 10%. Supply the correct voltage of 12 to 24 VDC 10%. Incorrect power supply Check the wiring to the power supply.
L4 Note) Weight (g) 3 5 5.5 6.5 8.5 9.5 19 22 36 38 42 44 76 82 Model D1 Applicable tube O.D. d AS1002F-02 AS1002F-23 AS1002F-04 AS1002F-06 AS2002F-04 AS2002F-06 AS2052F-06 AS2052F-08 AS3002F-06 AS3002F-08 AS3002F-10 AS3002F-12 AS4002F-10 AS4002F-12 D2 D3 D4 L1 L2 L3 L5 L6 L7 L8 M1 MIN. 18.4 21 21.7 22.7 25.4 26.5 28.2 29.5 33.6 34.4 36 37.1 44.1 45.1 6 8.4 9.3 11.6 9.3 11.6 12.8 15.2 13.2
Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 3 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Low level in tank 1 High circulating fluid discharge temp. 2 Circulating fluid discharge temp. rise 3 Circulating fluid discharge temp. drop 4 High circulating fluid return temp. 5 High circulating
Body pin hole Size Tightening torque 10 0.2 to 0.3Nm 15 0.3 to 0.5Nm 20 4.2 to 5.2Nm 30 4.2 to 5.2Nm 40 7.2 to 8.7Nm Size 10 , 15 Cover Assembly End cover Assembly Body pin hole Hexagon socket head bolt Fig.22 Size 20 , 30 , 40 (6) Perform operation test after assembling and check external leakage.
Model Screw Max. tightening Maximum screw-in depth (L mm) torque (Nm) MHZ2-10 M3 x 0.5 0.9 6 MHZ2-16 M4x0.7 1.6 4.5 MHZ2-20 M5 x 0.8 3.3 8 L L MHZ2-25 M6x1 5.9 10 MHZ2-32 M6x1 5.9 10 MHZ2-40 M8 x 1.25 13.7 13 Model Screw Max. tightening torque (Nm) Maximum screw-in depth (L mm) MHZ2-10 M3 x 0.5 0.69 5 MHZ2-16 M4x0.7 2.1 8 MHZ2-20 M5 x 0.8 4.3 10 MHZ2-25 M6x1 7.3 12 MHZ2-32 M6x1 7.9 13 MHZ2
218 210 to 420 Max. speed[mm/s] *1 *3 400 200 100 400 200 400 200 Actuator specifications Pushing speed[mm/s] 20 to 30 10 to 30 5 to 30 20 to 30 10 to 30 20 to 30 10 to 30 Max. acceleration/deceleration[mm/s2] 5000 Positioning repeatability [mm] 0.01 Lost motion[mm] *4 0.1 or less Screw lead[mm] 10 5 2.5 12 6 16 8 Impact/Vibration resistance[m/s2] *5 50/20 Actuation type Ball screw (In-line
10 0.3 MP 0.3 MPa 0.3 MPa 20 20 0.3 MPa 0.3 MPa 0.3 MPa 0.3 MPa 0.3 MPa 0.3 MPa 0.2 MPa 0.2 MP 0.2 MPa 5 5 10 10 0.2 MPa 0.2 MPa 0.2 MPa 0.2 MP 0.2 MPa 0.2 MPa 0.2 MPa 0 10 20 30 40 50 60 70 0 20 40 60 80 100 120 0 20 40 60 80 100 120 10 20 30 40 50 60 70 0 Gripping point R (mm) Gripping point R (mm) Gripping point R (mm) Gripping point R (mm) MHL2-25D1 2 MHL2-20D1 2 MHL2-20D MHL2-25D 200
MPa 5.0 MPa Rated pressure range 2.0 MPa 1.0 MPa 1.6 MPa 1.0 MPa Withstand pressure 1.5 MPa 2.4 MPa 3.0 MPa 5.0 MPa 12.5 MPa 30 MPa Power supply voltage When used as a switch output device 12 to 24 VDC 10% with 10% voltage ripple or less When used as an IO-Link device 18 to 30 VDC, including ripple (p-p) 10% Temperature characteristics 2% F.S. (25C standard) 3% F .S.
Applicable model AW40-06 AW40 AW30 AW20 AW10 Accessory Bracket assembly Note 1) AR30P-270AS AR30P-260S G36-10-01 GC3-10AS G36-2-01 GC3-2AS AD38 AD38NNote 6) AR40P-270AS AR40P-260S G46-10-02 GC3-10AS G46-2-02 GC3-2AS AD48 AD48NNote 6) AR40P-270AS AR40P-260S G46-10-02 GC3-10AS G46-2-02 GC3-2AS AD48 AD48NNote 6) AR10P-270AS AR10P-260S G27-10-R1 G27-10-R1 Note 3) AW20P-270AS AR20P-260S G36-10
Model No.: EX9-AWTS (M12 connector for socket 10 pieces.) Fig. 10-4 EX9-AWTS Note: Tighten the seal caps to the tightening torque specified (0.2 Nm). -54No.EX##-OMU0020-A Model No.:EX245-AWP (10 pieces for Push Pull connectors of power connection) The EX245-AWP can be used with the EX245-SPN1/EX245-SPN2. Mount the seal cap in the unused connector.
10) ( 10) 15 240 2 1 297 270 62 IDH Series 6.2. IDX-OM-W038 . (17) (17) mm IDH6IDHA6 ( ( 1.25 6.5 Rc1/2 N.C N.O M3 (N.C:) (N.O:) 2 6.5 :1.25m m :M3 Rc1/2 31 15 (N.O) (N O 10 2 244 35 184 392 17 2 1 80 223 321 300 1 485 70 372 568 ( 10) ( 10) 240 2 15 1 306 270 63 IDH Series IDX-OM-W038 . 6.3 6.2.