Series TUH Standard Type Hard Polyurethane Series P 20m bundle m 100m bundle TUH1073 TUH0858 TUH0644 TUH0428 TUH1288 Model 10 8 6 4 12 O.D. mm 7.3 5.8 4.4 2.8 8.8 I.D. mm Black (B) White (W) Blue (BU) Translucent (N) Specifications Air Note 1) Fluid Max. operating pressure (at 20C) (68F) 0.8MPa (116 psi) Note 2) Min. bending radius mm 10 18 24 30 36 2R Burst pressure At a temperature of

For driving air operated valves for fluid control N.C N.O N.C N.C Air operated style fluid control valve Vacuum valve Vacuum pad A, B 1(P) A, B 1(P) A, B 1(P) A, B 3(P) 3(R) 3(R) 3(R) 1(R) Vacuum releasing air Atmospheric pressure or micro pressure The characteristic values shown in the catalog are representative values, not warranting the performance. 4-3-1 2 Series SY100 Precautions Be

(Values at the initial period) VG JIS Symbol VP S070 VQ Model Valve model VKF VS3145 VS3135 P A C [dm3(sb Cv b Cv b Cv b Cv Flow characteristics 6.1 7.3 9.0 0.3 0.2 0.2 1.6 1.8 2.4 0.4 0.2 0.3 1.5 1.8 2.3 1/4 3/8 1/2 3/4 6.1 7.2 9.0 0.27 0.21 4.8 5.1 16 15 0.34 0.46 4.1 4.5 18 20 VZ VS AC DC 30 or less

B W 7.5 (5) (mm) D-A9, D-A9V D-M9W, D-M9 D-M9WV, D-M9V Bore size (mm) A A W B W B A W B 6 12.5 3.5 (6) 16.5 7.5 2.5 16.5 5.5 2.5 10 11.0 2.0 (0.5) 3.5 15.0 2.0 7.5 15.0 0 7.5 16 18.0 2.0 (0.5) 4.0 22.0 2.0 8.0 22.0 0 8.0 20 26.0 4.5 (2) 6.5 30.0 0.5 10.5 30.0 2.5 10.5 Note 1) Negative figures in the table W indicate an auto switch is mounted inward from the edge of the cylinder body.

How to determine the auto switch installation position MHZ2 Step 2) Insert auto switch into the switch installation groove from direction B. "Set up as directed with power connected under no pressure or low pressure." A B MHZJ2 MHQ Step 3) Slide the auto switch in the direction of the arrow until the light illuminates.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 12 V Body size Port size Rc Option Symbol P/A port R port B (Bracket) F (Foot) G (Pressure gauge) N (Silencer) 00 M5 00 M5 01 00 01 02 00 02 03 04 Symbol Mounting Without sub-plate M5 Without sub-plate M5 D B 1 8 Without sub-plate Base mounted 1 8 1 4

Description No. 2 Common IN Individual IN Common IN Individual IN Bonnet Polyacetal Regulator NARM2500-A-N02 NARM2500-B-N02 NARM3000-A-N03 NARM3000-B-N03 9 Regulator 1 Component Parts 10 End plate R 1 No.

For driving air operated valves for fluid control N.C N.O N.C N.C Air operated style fluid control valve Vacuum valve Vacuum pad A, B 1(P) A, B 1(P) A, B 1(P) A, B 3(P) 3(R) 3(R) 3(R) 1(R) Vacuum releasing air Atmospheric pressure or micro pressure The characteristic values shown in the catalog are representative values, not warranting the performance. 4-3-1 Series SY100 Precautions Be sure

(see drawing on the left) Product Groove Bottom of the body Finger Bracket A Mounting of bracket B Fix the bracket B with the set screw (2 pcs.) included in the package. Refer to the table below for the 2) tightening torque. Bracket B Model No. Tools Tightening torque AMK50 Phillips screwdriver(+) 1.50.2 N m AMK60 Set screw (2 pcs.) -11- 8. Troubleshooting Refer to [9.

B C D 44 Mounting J ig to the piston 43 Mounting to workpiece Fem ale thread type Male thread type D o No.LZ-OM00401 B (3/3) (44) 1908-56 38 88 Hungary (36) 1-371 1343 Turkey (90) 212 221 15 12 Finland (358) 9-859 580 Portugal (351) 22 610 89 22 Denmark (45) 70 25 29 00 Poland (48) 22-548 50 85 Greece (30) 1-342 60 76 Switzerland (41) 52-396 31 31 France (33) 1-64 76 10 00 Spain (34) 945-

Thread type and port size C D E Material Number of 1 set Male thread A side Female thread B side Mounting hole dia.: 10.5 IDF-AP604 NPT1 Rc1 1.97 (50) 1.06 (27) 1.81 (46) [inch (mm)] Brass 2 IDF-AP606 NPT1 1/2 Rc1 1/2 2.17 (55) 1.22 (31) 2.13 (54) Part no.

Fittings & Tubing Air Cylinders Rotary Actuators Size: 50 Single shaft Double shaft 8 x M8 x 1.25 depth 8 (Opposite side 4 locations) 118 44 62 4 x 9 (Mounting hole) 48 20 15 11 0 0.2 15 (g6) 14 0 0.2 25 (h9) 17 M5 x 0.8 (Vacuum suction port) 15 (g6) 25 5 Auto switch 2 x Cushion valve (Width across flats 3) 9.5 9.5 0 0.030 5 36 2.5 98 7.5 6 7.5 6 108 5 33 14.5 41 A port 2 x Rc1/8 B port 8.5

Fittings & Tubing Air Cylinders Rotary Actuators Side tapped mounting [1/N1] Through-holes in open/close direction [2/N2] 4 x MM through Thread for mounting attachment C C B A 4 x H through Hole for mounting attachment S S O O B A (mm) (mm) MM M2.5 x 0.45 M3 x 0.5 M4 x 0.7 M5 x 0.8 C 2 2.5 4 5 H 2.9 3.4 4.5 5.5 B 5.7 7 9 12 B 5.7 7 9 12 Model A 3 4 5 6 Model A 3 4 5 6 11221122112211221 N1

Resolution 0.1mm/pulse Accuracy 0.2mm Note 1) Output Type Open Collector (30V, 50mA) Output signal Phase A & B with Differential Output Max.

If air pressure is applied from the B port side, the shaft rotates counterclockwise.

8370: JIS B 8361: JIS B 9960-1: -1 ) JIS B 8433: *2) 1. 2. 3. 1. 2. 3. 4. 2 - / 1 1.5 *3) *3)1 1 () 3 - 2

Width across flats Tightening torque for nut B (Nm) Holding force Adjustment bolt Nut A Nut B adjustment range Model Adjustment bolt Nut A Nut B MHM-16D1 2 10 6 1.5 5 MHM-25D1 3 14 8 5.2 5 MHM-32D1 3 14 8 5.2 5 MHM-50D1 5 24 17 42 5 15 - Caution 1. Do not apply external forces to the holding force adjusting part other than for the purpose of holding force adjustment.

B C D E F G H 148 206 246 Model MHL2-40D MHL2-40D1 MHL2-40D2 80 138 178 188 246 286 288 406 486 116 174 214 348 466 546 72 130 170 12-4-13

hole F Applicable screw M5 hexagon socket head cap screw M6 hexagon socket head cap screw M8 hexagon socket head cap screw Model AMP220 AMP320 AMP420 E OUT Maintenance space (mm) C B Bracket related dimensions Element service indicator related dimensions Port size (nominal size B) Model A D E I 66 80 90 J K L M N O P Q R S F 80 120 180 G 123 169 237 H AMP220 AMP320 AMP420 76 90 106 76 90

When mounting a valve with its coil positioned downwards, foreign objects in the fluid will adhere to the iron core leading to a malfunction. 28 to 30 G, Rc 3/4 36 to 38 G, Rc 1 VCB 4. Connection of piping to products When connecting piping to a product, refer to its instruction manual to avoid mistakes regarding the supply port, etc.