SMC Corporation of America
Elite Part Number Search
Search Results "VXR2150D-06T-3C"

Function: 2 (2 Position, Double), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: E (Grommet Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4), Thread: T (NPTF)

Function: 3 (3 Position Closed Center), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Port Size: 06 (3/4), Thread: T (NPTF)

Function: 3 (3 Position Closed Center), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4), Thread: T (NPTF)

Function: 2 (2 Position, Double), Model: 0 (Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24 VDC), Lead Wire: F (Plug-in), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4), Thread: T (NPTF)

Function: 2 (2 Position, Double), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: E (Grommet Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: B (Locking Slotted Style), Port Specification: Side Ported, Port Size: 06 (3/4), Thread: T (NPTF)

Function: 1 (2 Position, Single), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4), Thread: T (NPTF)

Function: 3 (3 Position Closed Center), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4), Thread: T (NPTF)

Function: 2 (2 Position, Double), Model: 0 (Plug-in), Body Option: 0 (Standard), Voltage: 5 (24 VDC), Lead Wire: F (Plug-in), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Port Size: 06 (3/4), Thread: T (NPTF)

Function: 2 (2 Position, Double), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: R (External Pilot), Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4), Thread: T (NPTF)

Function: 1 (2 Position, Single), Model: 0 (Plug-in), Body Option: 0 (Standard), Pilot: R (External Pilot), Voltage: 5 (24 VDC), Lead Wire: F (Plug-in), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4), Thread: T (NPTF)

Function: 1 (2 Position, Single), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4), Thread: T (NPTF)

Function: 4 (3 Position Exhaust Center), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4), Thread: T (NPTF)

Function: 3 (3 Position Closed Center), Model: 0 (Plug-in), Body Option: 0 (Standard), Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: F (Plug-in), Surge Suppressor: None, Port Size: 06 (3/4), Thread: T (NPTF)

voltage suppressor) 24 VAC 12 VDC 12 VDC 24 VDC Electrical option Other option Faston terminal 100 VAC 110 VAC 200 VAC 230 VAC DIN terminal (With surge voltage suppressor) 48 VAC 2G 2H 2V 2J 220 VAC 240 VAC 24 VAC 12 VDC 24 VDC 2K 2L 100 VAC 110 VAC 200 VAC 230 VAC 2M 2N 2P 2Q 2R 2S Conduit terminal (With surge voltage suppressor) 48 VAC 220 VAC 240 VAC 2W 24 VAC 12 VDC 24 VDC 2T 3A 3B 3C

or less (at load current of 80 mA) Response time 2.5 ms or less (with anti-chattering function: 20, 100, 500, 1000, 2000 ms) Short circuit protection Yes Repeatability 0.2% F.S. 1 digit Switch output Hysteresis Hysteresis mode Variable from 01 Window comparator mode Display type 3 1/2 digit, 7-segment LED, 1-color display (Red) Display accuracy 2% F.S. 1 digit (Ambient temperature at 25 3C

settable increment 0.001 MPa 0.001 MPa Withstand pressure 1.5 MPa 2.4 MPa When used as a switch output device 12 to 24 VDC 10% with 10% voltage ripple or less Power supply voltage When used as an IO-Link device 18 to 30 VDC, including ripple (p-p) 10% Power supply Current consumption 35 mA or less Protection Polarity protection Display accuracy 2% F .S. 1 digit (Ambient temperature of 25 3C

value 0 to 65535 (Low byte first) 28..29 0..7 (Ch1 out) Fault value 0 to 65535 (Low byte first) 30..31 0..7 (Ch1 out) Idle value 0 to 65535 (Low byte first) -104No.EX-OMX1011 Configuration format (EX600-LAB1 / EX600-LBB1) Byte 0 to 5 EX600-LAB1 / EX600-LBB1 (46 byte) Byte Bit Parameter Setting value 0..3 Unit No. 0..8 0 4..7 Parameter type 1 1 0..7 Unit ID EX600-LAB1:3B (Hex) EX600-LBB1:3C

Pump automatic running and stopping is repeated to prevent freezing by maintaining circulating fluid temperature at 3C to 5C. Pump automatically starts operating if the circulating fluid temperature drops below 3C. Circulating fluid is heated by the pump power generated by pump operation.

Pump automatic running and stopping is repeated to prevent freezing by maintaining circulating fluid temperature at 3C to 5C. Pump automatically starts operating if the circulating fluid temperature drops below 3C. Circulating fluid is heated by the pump power generated by pump operation.

Pump automatic running and stopping is repeated to prevent freezing by maintaining circulating fluid temperature at 3C to 5C. Pump automatically starts operating if the circulating fluid temperature drops below 3C. Circulating fluid is heated by the pump power generated by pump operation.