Cylinder specification Bore size (mm) 32 40 50 63 80 100 Double acting/single rod Operating method Air Fluid 1.5MPa Proof pressure 1.0MPa Max. operating pressure 0.08MPa Min. operating pressure Without auto switch: -10 to 70 With auto switch -10 to 60 Ambient and fluid temperature Operating fluid temperature Not required (non-lube) Lubrication 50~1,000mm/s * Piston speed Allowable stroke

Model/Valve Specifications Av x 10-6m2 Cv converted C [dm 3/(sbar)] b Cv Water, Oil, Steam Air Flow characteristics Maximum operating pressure differential (MPa) Min. operating pressure differential (MPa) 10 10 15 10 15 20 Connection Orifice Max. system pressure (MPa) Weight (g) Model Water AC DC AC DC AC DC AC Air Oil Steam size (mm) Thread VXP2130-02 0.7 0.7 1.0 0.7 1.0 1.0 1 4 740 500

.*2 Screw-in type Nil Without nozzle 01 Symbol Size Nil Rc3/8 N NPT3/8 F G3/8 50 mm IBG1-12-10-50 02 100 mm IBG1-12-10-100 03 150 mm IBG1-12-10-150 04 300 mm IBG1-12-10-300 11 Long nozzle*1 With S coupler/One-touch fitting 50 mm IBG1-12-10-50S 12 100 mm IBG1-12-10-100S 13 150 mm IBG1-12-10-150S 14 300 mm IBG1-12-10-300S Symbol Applicable tubing O.D. Part no.

flow 1 L 10 L 100 L Accumulated volume per pulse (Pulse width = 50 msec.) 1 L/pulse 10 L/pulse 100L/pulse Accumulated value hold 3 Every 2 or 5 minutes, The stored accumulated flow is held even when the power supply is OFF.

L/min Flow Minimum resolution Accumulated flow 10 L 100 L Accumulated volume per pulse (Pulse width = 50 msec.)

Viscosity Transfer is possible up to about 100 mPas.

A to B C to D 500 L 5 to 500 -25 to 525 L/min 1000 L 10 to 1000 -50 to 1050 2000 L 20 to 2000 -100 to 2100 PFMC7 40 to 4000 -200 to 4200 500 L 0.17 to 17.66 -0.90 to 18.50 cfm 1000 L 0.35 to 35.31 -1.80 to 37.10 2000 L 0.70 to 70.63 -3.50 to 74.20 The flow ranges and relationship between the fluid and PD are shown in the figures below.

Specifications Fluid Air Operating pressure range PSI (MPa) Body ported type 22~100 (0.15 to 0.7) Internal pilot Max. 122 Ambient and fluid temperature F 15 or less Response time ms 10 Max. operating frequency Hz Non-locking push type, Push-locking slotted type Manual override Individual pilot exhaust type.

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, TIE ROD, DUAL STK, ACTUATOR, CA1/CA2 TIE-ROD CYLINDER, MC, 40MM CA1 OTHERS (COMBO), 8.15710 lb

A to B C to D 500 L 5 to 500 -25 to 525 L/min 1000 L 10 to 1000 -50 to 1050 2000 L 20 to 2000 -100 to 2100 PF2MC7 40 to 4000 -200 to 4200 500 L 0.17 to 17.66 -0.90 to 18.50 cfm 1000 L 0.35 to 35.31 -1.80 to 37.10 2000 L 0.70 to 70.63 -3.50 to 74.20 The flow ranges and relationship between the fluid and PD are shown in the figures below.

15 20 25 32 10, 20, 30, 40, 50 Vacuum suction type Relief type M5 x 0.8 10, 20, 30, 40, 50, 75, 100 1/8 Double acting (Both sides) Non-lube 10-/12-/21-CXS6 6 single rod 10-/12-/21-CXS10 10-/12-/21-CXS15 10-/12-/21-CXS20 10-/12-/21-CXS25 10-/12-/21-CXS32 10, 20, 30, 40, 50 10 15 20 25 32 M5 x 0.8 10, 20, 30, 40, 50, 75, 100 1/8 Specifications Suction flow rate of vacuum suction type (Reference

Give adequate confirmation, and then determine a model, just because the compatibility list shows the general case. 10-12 10-11 10-10 10-9 10-8 10-7 10-6 10-5 10-4 10-3 10-2 10-1 1 10 102 10-12 10-11 10-10 10-9 10-8 10-7 10-6 10-5 10-4 10-3 10-2 10-1 1 101 102 103 104 105 106 107 108 109 Pa Vacuum piping direction: if the system uses a vacuum pump, we ask that you install the vacuum pump

Function Content 10 Sets the position of station numbers 100 and 10 1->10, A->100, B->110, C->120 1 Sets the position of station number 1 Example: When station number is 120: set C to x10 and 0 to x1 When station number is 111: set B to x10 and 1 to x1 HOLD/CLEAR switch: Sets the output status when the fieldbus has a communication error or is in idling state.

RLQB40-100 RLQB50-30 RLQB50-40 RLQB50-50 RLQB50-75 RLQB50-100 RLQB63-30 RLQB63-40 RLQB63-50 RLQB63-75 RLQB63-100 90 95 100 110 120 145 170 100 105 110 120 130 155 180 120 130 140 165 190 125 135 145 170 195 Mounting bolt 8 C Spring washer D Note) When mounting 50 to 63 cylinders from the rod side, be sure to use the attached flat washers because the bearing surface is limited. 9 13.5 12.5

F A A Lr Lr = 200mm L X S 400 8 60 Table displacement (m) LXSH-150 Table displacement (m) Table displacement (m) 350 7 LXSH-150 LXSH-150 50 300 6 LXSH-125 LXSH-125 250 5 40 LXSH-125 LXSH-100 LXSH-100 200 4 30 LXSH-75 LXSH-100 LXSH-75 3 150 20 LXSH-50 LXSH-75 2 100 LXSH-50 LXSH-50 10 1 50 1 2 3 4 5 6 8 9 7 0 0 0 1 2 3 4 5 6 8 9 10 10 10 7 1 2 3 4 5 6 8 9 7 Weight (kg) Weight (kg) Weight (kg

Indicate 10 to 12 stations on the manifold specification sheet.) One station is used for serial unit mounting.

Cylinder stroke (mm) Model Cushion Bore size (mm) 40 63 100 Standard stroke (mm) Auto switch mounting Action Port size Lubrication Model Rubber Air 10-MGF40 10-MGF63 10-MGF100 1/8 Relief type (Both sides) Double acting 30, 50, 75, 100 1/4 Non-lube Non-standard intermediate strokes (in 5 mm increments) are available by attaching a spacer of 5, 10, 15, 20 or 25 mm width.

CVS1K 40, 50 63, 80 100 J Standard 10-15-67 Double acting DNonrotating rod 40, 50 63 10-15-78 -X Series MVGQ 2012, 16 20, 25 32, 40 50, 63 80, 100 Data 10-16-1 Double acting 10-15-1 Series CV Valve Mounted Cylinder Precautions Be sure to read before handling.

0 q 4 Series LVR Dimensions Integral ttings/LQ3 4 x 7 Mounting hole 1/8 (Rc, NPT) Pilot port A H D B G Model A B C D E LVR20-Z07(06) 40 40 49.3 68 20.1 LVR40-Z11(10) 82.5 82.5 89 115 33 LVR40-Z13(12) 82.5 82.5 89 115 33 LVR50-Z19 100 100 117.5 135 45 Breathing port M5 x 0.8 IN Model F G H J LVR20-Z07(06) 8 27 56 88 LVR40-Z11(10) 14 64.5 100 150.5 LVR40-Z13(12) 14 64.5 100 159.5 LVR50-Z19

20 10 0 100 Suction flow [L/min(ANR)] Air consumption [L/min(ANR)] Vacuum pressure Vacuum pressure [kPa] Vacuum pressure [kPa] 80 60 Suction flow 40 20 Air consumption 0 0 10 20 30 40 Supply pressure [MPa] Suction flow [L/min(ANR)] ZHP-10 ZHP-10 (Supply pressure: 0.35 MPa) 100 90 80 70 60 50 40 30 20 10 0 0 0.1 0.2 0.3 0.4 0.5 0.6 100 90 80 70 60 50 40 30 20 10 0 100 Suction flow [L/min(