EX500-DXPB Install the product using 2 M5 screws x 20 mm or longer with a head 9 to 11. 51 No.EX-OMS0014-A Wiring EX500-DXPA Branch wiring Connect the branch cable to the branch connector (IN/OUT). Refer to page 12 for wiring. Sensor wiring Connect the sensors to the sensor connectors. Pin layout of the sensor connector M8 connector (3 pin, socket) No.

n) + 23 Common IN .13 (57) NARM1000 1 8 1 8 (79 X n) + 25 Individual IN Common IN 1 4 1 8 (188 X n) + 43 NARM2000 .3 (136) Individual IN 1 8 1 8 (187 X n) + 45 Space Saving How to Order Option NARM 1000 A1 5 01 G 1 1 Set at 0.2MPa Note1) Pressure gauge for 1MPa is used.

Series: 25A-ISE20, Rated Pressure Range: A (-0.1 to 1 MPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (Female Thread), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)

Series: 25A-ISE20, Rated Pressure Range: A (-0.1 to 1 MPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (Female Thread), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)

Series: 25A-ISE20, Rated Pressure Range: A (-0.1 to 1 MPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (Female Thread), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: B (Panel Mount Adapter), Operation Manual: K (Operation Manual, Calibration Certificate)

Series: 25A-ISE20, Rated Pressure Range: A (-0.1 to 1 MPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: M5 (Female Thread), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)

Series: 25A-ISE20, Rated Pressure Range: A (-0.1 to 1 MPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: M5 (Female Thread), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)

Series: 25A-ISE20, Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: SI Unit Only, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: -, Operation Manual: -

Series: 25A-ISE20, Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: SI Unit Only, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: Panel Mount Adapter, Operation Manual: Operation Manual, Calibration Certificate

Series: 25A-ISE20, Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: -, Operation Manual: -

ASD Body size Port size M5 M5 x 0.8 U10/32 10-32UNF 1 M5 x 0.8 10-32UNF AS AS-FE 2 F A 1 AS 1 M5 06 0 E KE Body size 1 AS-FG F A 1 AS 2 01 06 2 0 S Body size 2/3/4 AS-FP AS-FM Body size Made to Order Refer to page 562 for details.

Port size Body size M5 M5 x 0.8 U10/32 10-32UNF 1 M5 x 0.8 10-32UNF 1 0 2 06 AS 1F S E M5 Body size 1 S Body size 2/3/4 AS 01 2 0 2 1F S 06 With indicator Made to Order Refer to page 15 for details. Body size 2 1/8, 1/4 3 3/8 4 1/2 Type 2 Elbow 3 Universal Seal method Nil Without sealant S With sealant Control type Note) Note) Face seal type is used for the G thread type.

Body size Port size M5 M5 x 0.8 U10/32 10-32UNF 1 M5 x 0.8 10-32UNF AS 2 0 F A 1 1 M5 06 G Body size 1 AS 2 0 S F A 1 2 01 06 G Body size 2/3/4 Body size Made to Order Refer to page 678 for details. 2 1/8, 1/4 3 3/8 4 1/2 Push-lock type Type 2 Elbow 3 Universal Seal method Nil Without sealant S With sealant Note) Face seal method is used for the G thread type.

When reusing the tubing, cut off the previously installed portion of the tubing to avoid possible leakage and/or disconnection of the tubing. 3.2, 4 Port size 3 5 32 04 M3 x 0.5 M5 x 0.8 3.2 4 15-6-28

Note Bracket A ZS-46-A1 Tapping screw: Nominal size 3 x 8 L (2 pcs.) Bracket B ZS-46-A2 Tapping screw: Nominal size 3 x 8 L (2 pcs.)

Ports 2, 4 size (metric) Ports 2, 4 Symbol C3 C4 C6 M5 CM Ports 1, 3, 5 3.2 One-touch fitting 4 One-touch fitting 6 One-touch fitting M5 threads Mixed size/with port plug Top ported elbow 3.2 One-touch fitting Top ported elbow 4 One-touch fitting Top ported elbow 6 One-touch fitting M5 threads Bottom ported elbow 3.2 One-touch fitting Bottom ported elbow 4 One-touch fitting Bottom ported

Currently available in metric to suit tube sizes from 3.2mm to 10 mm OD, and thread sizes from M5 to + R(PT)Speed controller with one-touch fittings, Body sizes: M5, 1/8, A1/4, Cylinder direct connected elbow style, Meter-in or meter-out control, Port sizes: M5, 01, 02, SPEED CONTROLLER LOW SPD, AIRLINE EQUIPMENT, AS FLOW CONTROL, CD, AS 1/8INCH STANDARD (NPT), .13227 lb, ModelPort

(between live parts and case)50 M or more (at 500 VDC by megameter) between live parts and case01: R 1/8, M5 x 0.8 T1: NPTF 1/8, M5 x 0.80X: With suction filter (For mounting on ZX unit) 0R: Base mount type (For mounting on ZR unit)35 g (Including 0.6 m-Long lead wire)Oil-resistant vinyl cabtire code 3 cores, ?

EX500-DXPB Install the product using 2 M5 screws x 20 mm or longer with a head 9 to 11. -55No.EX-OMT0009 Wiring EX500-DXPA Branch wiring Connect the branch cable to the branch connector (IN/OUT). Refer to page 12 for wiring. Sensor wiring Connect the sensors to the sensor connectors. Pin layout of the sensor connector M8 connector (3 pin, socket) No.