Positioning Time Guide (for Horizontal Mount) For transfer load of 0kg For transfer load of 3kg Positioning time (sec) Positioning time (sec) Positioning distance (mm) 200 100 50 10 1 Positioning distance (mm) 100 200 50 10 1 50 4.2 2.1 1.1 0.3 0.1 50 2.1 4.1 1.1 0.3 0.1 Speed (mm/s) Speed (mm/s) 100 2.1 1.1 0.6 0.2 0.1 100 1.1 2.1 0.6 0.2 0.1 200 1.1 0.6 0.3 0.1 0.1 200 0.6 1.1 0.3 0.1 0.1
32 25, 50, 75, 100, 125, 150, 200 40 25, 50, 75, 100, 125, 150, 200, 250, 300 MB1 Note 1) Other intermediate strokes can be manufactured upon receipt of order.
Model LC7R-K1A (Refer to page 200 for details.)
st to 300 st Over 300 st Over 25 st to 100 st 25 st Over 100 st to 200 st Over 200 st to 300 st Over 300 st Over 25 st to 100 st Over 100 st to 200 st 25 st Over 300 st Over 25 st to 100 st Over 100 st to 200 st Over 200 st to 300 st 25 st or less Over 300 st Over 30 st to 100 st Over 100 st to 200 st Over 200 st to 300 st 30 st or less Over 300 st Over 25 st to 100 st Over 100 st to 200
In the case of bore size 180 and 200, piston seals are NLP.
M6 x 1.0 M8 x 1.25 A, DB, E Dimensions: MLGPL (Ball bushing bearing) A, DB, E Dimensions: MLGPM (Slide bearing) A E A E Bore size (mm) 79.5 84 128.5 Bore size (mm) DB DB st 50 50 < st 200 200 < st 12 16 20 st 50 50 < st 200 200 < st st 30 st 50 30 < st 100 50 < st 100 100 < st 200 200 < st 350 10 13 16 st 30 st 50 30 < st 100 50 < st 100 100 < st 200 200 < st 350 51 51 58.5
120 201 to 300st 200 200 301 to 400st 300 300 20 to 39st 29 29 40 to 124st 39 39 125 to 200st 77 77 201 to 300st 117 117 301 to 400st 167 167 20 25 20 to 400 WA WB Bore size (mm) Standard stroke (mm) 25 to 49st 24 24 24 28 28 48 50 to 124st 48 48 48 52 52 72 125 to 200st 124 124 124 128 128 148 201 to 300st 200 200 200 200 200 220 301 to 400st 300 300 300 300 300 320 25 to 49st 33 34 36 38
M6 x 1.0 M8 x 1.25 A, DB, E Dimensions: MLGPL (Ball bushing bearing) A, DB, E Dimensions: MLGPM (Slide bearing) A E A E Bore size (mm) 79.5 84 128.5 Bore size (mm) DB DB st 50 50 < st 200 200 < st 12 16 20 st 50 50 < st 200 200 < st st 30 st 50 30 < st 100 50 < st 100 100 < st 200 200 < st 350 10 13 16 st 30 st 50 30 < st 100 50 < st 100 100 < st 200 200 < st 350 51 51 58.5
S L, Z S L, Z 1 1 1 1 4 1 2 PB AC 2 Ordering example (Example) Series VXR22, Rc 1 1/4, 200 VAC, Conduit terminal (Part no.)
400 300 200 100 0 VF B VFR VP4 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 800 700 600 500 400 300 200 100 0 VZS C VFS VS4 800 700 600 500 400 300 200 100 0 VQ7 D EVS VFN 800 700 600 500 400 300 200 100 0 E It is when the cylinder is extending that is meter-out
(Example) When STA = 20, STB = 5000 and STC = 200, the actual arc part times are as follows. At acceleration: 100 ms 20 20 = 100 [ms] < 200 [ms] Therefore, it will be limited to 100 [ms]. At deceleration: 200 ms 20 5000 = 400 [ms] > 200 [ms] Therefore, it will be 200 [ms] as you set. Setting range: 0 to 5000 5 90 5.
200 16 20 10, 25, 40, 50, 80, 100, 125, 160, 200, 250, 300 1000 25 Refer to pages 101 to 111 for cylinders with auto switches.
T-slot 2 dimensions Compatible Motors Switch Internal Circuit D-Y7GL Motor output (W) Motor model Brake Manufacturer Power supply voltage (VAC) Motor specification symbol Controller driver model + Brown lead wire 100/110 200/220 100 200 100/115 200/230 100/115 200/230 100/115 200/230 100/115 200/230 100/115 200/230 100/115 200/230 LC1-1B1H1Without brake (Horizontal specification) 50 Main
VAC (50/60 Hz) Three phases 200 VAC (50/60 Hz) Single phase 100 VAC (50/60 Hz) Single phase 200 VAC (50/60 Hz) Single phase 100 VAC (50/60 Hz) Three phases 200 VAC (50/60 Hz) Power source 90 130 0.4 0.45 1.44 1.4 50 60 0.4 0.35 55 65 0.8 0.9 38 46 132 x 2 170 x 2 0.23 0.26 50 Hz 60 Hz 50 Hz 60 Hz Power consumption (W) 0.46 0.52 Current (A) Compact size and lightweight Uses minimal floor
500 400 300 200 Data Maximum speed: V (mm/s) Maximum speed: V (mm/s) Graph (7) Graph (4) 0.5 MPa ) P 0.5 MPa ) P 250 4000 4000 3000 3000 200 180 2000 2000 160 250 140 Load weight: m (kg) Load weight: m (kg) 125 200 1000 1000 700 800 900 700 800 900 180 160 600 600 140 500 500 125 400 400 300 300 200 200 100 100 100 500 400 300 200 100 500 400 300 200 Maximum speed: V (mm/s) Maximum speed:
100/200 100/200 100/200 100/200 100/200 100/200 100/200 100/200 100/200 ** Non-Standard Product, consult factory for lead time.
VAC (50 Hz) *5 Single-phase/Three-phase: 200/220 VAC (60 Hz) Three-phase: 200 VAC (50 Hz) Three-phase: 200/220 VAC (60 Hz) Single-phase 200 V 810/940 810/940 Power consumption [W] Electric specifications 50/60 Hz *6 Three-phase 200 V 850/1070 850/1070 1450/1890 2000/2500 Single-phase 200 V 4.3/4.7 4.3/4.7 Operating current [A] Refrigerant R407C (HFC) IDF F 50/60 Hz *6 Three-phase 200
B2 LECSB2/Pulse input (Absolute encoder) 200 V to 230 V C2 LECSC2/CC-Link (Absolute encoder) 200 V to 230 V !
200 300 300 0.4 MPa 0.4 MPa 0.4 MPa 0.4 MPa 150 150 0.3 MPa 0.3 MP 0.3 MPa 0.3 MPa 0.3 MP 0.3 MPa 200 200 0.3 MPa 0.3 MPa 0.3 MPa 0.3 MP 0.3 MPa 100 100 0.2 MPa 0.2 MP 0.2 MPa 0.2 MPa 0.2 MP 0.2 MPa 0.2 MPa 0.2 MPa 0.2 MP 0.2 MPa 0.2 MPa 100 100 50 50 0.1 MPa 0.1 MPa 0.1 MPa 0.1 MPa 0.1 MPa 0.1 MP 0.1 MPa 0.1 MPa 0.1 MP 0.1 MPa 50 100 150 200 0 0 50 100 150 200 0 40 80 120 160 200 0 40 80
MSM011P1A MSM012P1A 100 100/115 200/230 100/115 200/230 100/115 200/230 MSD011P1E MSD013P1E MR-C10A1 MR-C10A SGDE-01BP SGDE-01AP Matsushita Electric Industrial Co., Ltd. For a non-standard motor specification, when the motor is mounted before shipping, the driver is included but the cable that connects the motor and driver is optional. Refer to page 178 for part numbers.