Supply(P),Vacuum(V), One-touch Fitting: Supply (P) Port: ø1/4"; Vacuum (V) Port: ø1/2", Exhaust Type: Silencer Exhaust, Supply/Release Valve Combination: None, Rated Voltage: None, Electrical Entry: None, Light/Surge Voltage Suppressor: w/o Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Vacuum Pressure Sensor: None, Output Specifications: PNP Open Collector 2 Outputs
Input/Output Specification: NPN 5 Outputs + Auto-shift Input, Unit Specification: w/Unit Selection Function, Mounting: Panel Mount Adapter + Front Protection Cover, Sensor Connector: -, Power Supply: -, Output Specification: -
Input/Output Specification: PNP 5 Outputs + Auto-shift Input, Unit Specification: w/Unit Selection Function, Mounting: Panel Mount Adapter + Front Protection Cover, Sensor Connector: -, Power Supply: -, Output Specification: -
Input/Output Specification: 3 [IO-Link + PNP 4 Outputs or PNP 5 Outputs (SIO Mode)], Unit Specification: w/Unit Selection Function, Mounting: Panel Mount Adapter + Front Protection Cover, Sensor Connector: -, Power Supply: -, Output Specification: -
Input Specification: 0 (Voltage Input), Output Specification: 4 (PNP Open Collector 2 Outputs Switching Type + Analog Current/Auto-shift Function Switching Type), Unit Specification: w/Unit Selection Function, Lead Wire: w/o Lead Wire, Bracket/Panel Mount: B (Panel Mount Adapter)
ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: 06 [Vacuum: Rc3/4; Supply: 8 (Metric)], Exhaust Method: P (Port Exhaust, Rc1, G1, NPT1), Supply Valve/Release Valve Combination: w/o Valve, Rated Voltage: None, Electrical Entry: None, Light/Surge Voltage Supprressor: None, Manual Override: Non-locking Push Type, Vacuum Pressure Sensor: None, Output: B
Input, Output Specification: 1 (PNP 5 Outputs + External Input), Unit Specification: Unit Selection Function, Panel Mount: B (Panel Mount Adapter + Front Protective Cover)
Input Specification: 0 (Voltage Input), Output Specification: 0 (NPN Open Collector 2 Outputs Switching Type + Analog Voltage/Auto-shift Function Switching Type), Unit Specification: w/Unit Selection Function, Lead Wire: w/o Lead Wire, Bracket/Panel Mount: B (Panel Mount Adapter)
Air Volume: Rapid Deionizing Type, 0.66m³/min, Output: NPN Output, Power Supply Cable, AC Adapter: Power Supply Cable, 3m, Bracket: B (Bracket)
Output: NPN Output, Power Supply Cable, AC Adapter: Power Supply Cable, 3m, Bracket: B (w/Bracket)
data) a: Inclination b: Intercept [Inclination and intercept to the unit specification] Series Unit Flow range Inclination a Intercept b 4 L 0.125 0 L/min 16 L 0.25 0 40 L 0.5 0 PF2MC7 4 L 0.004415 0 cfm 16 L 0.0088275 0 40 L 0.0176575 0 [Calculation example] (1) Conversion from the process data to the flow measurement value (For PF2MC7 series, unit L/min, flow range 1000 L and PD = 2500
3 A-y A-u A-i A-y B-q B-w B-e B-r B-w B-t B-y B-t Orifice body PTFE seal O-ring Sleeve O-ring O-ring O-ring Name plate O-ring O-ring Orifice body Name plate O-ring O-ring O-ring O-ring Orifice O-ring O-ring Name plate O-ring O-ring O-ring O-ring PEEK resin Special PTFE Special FKM POM Special FKM Special FKM Special FKM Special FKM Special FKM PEEK resin Special FKM Special FKM HNBR Special
setting status signal B EnabledOpen A Output the input signal as it is SW1 Pass through signal of the contact input signal 1 B Reverse output of the input signal A Output the input signal as it is SW2 Pass through signal of the contact input signal 2 B Reverse output of the input signal A Selected alarm occurrence : Close A.SEL Selected alarm status signal B Selected alarm occurrence : Open
5-2.Dimensions C E C E E (KF flange) Fd (K flange) Fn D H B A G A Unit: mm Model A B C D E Fn Fd G H XLA-16-2 40 108 38 20 30 17 44 XLA-25-2 50 121 48 27 12 40 26 44 XLA-40-2 65 171 66 39 11 55 41 67 XLA-50-2 70 185 79 46 11 75 52 72 XLA-63-2 88 212 100 55 11 87 95 70 76 XLA-80-2 90 257 117 65 11 114 110 83 104 12 XL-OMS0001-B 6.
Comply with the requirements for FISCO field device Class I, Division 2, Groups A, B, C, and D; T4/ T5/T6 Ex ic IIC T4/T5/T6 Gc Class I, Zone 2 AEx ic IIC T4/T5/T6 Gc Ui 32 V, Ii 380 mA, Pi 5.32 W, Ci 5 nF, Li 10 H.
JIS B 8361: General rules for hydraulic equipment. JIS B 9960-1: Safety of machinery Electrical equipment for machines. (Part 1: General requirements) JIS B 8433-1993: Manipulating industrial robots Safety. etc. *2) Labor Safety and Sanitation Law, etc. Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury.
Adjustment bolt b CRA1 Adjustment bolt d CRQ2 q First adjust both rotation end positions. Apply pressure to ports A and C to adjust adjusting bolt b. Apply pressure to ports B and D to adjust adjusting bolt a. Lock the bolts with fixing nuts after adjustment. w Next, apply pressure to ports A to D to adjust the center position. Loosen the fixing nuts for adjusting bolts c and d.
Nil M5 x 0.8 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/4 TF G 1/8 G 1/8 G 1/8 G 1/4 TN NPT 1/8 NPT 1/8 NPT 1/8 NPT 1/4 CY3B15 CY3B20 CY3B25 CY3B32 CY3B40 b C H B d M10 x 1.0 M20 x 1.5 M26 x 1.5 M32 x 2.0 H 4 8 8 10 B 14 26 32 41 C 16.2 30 37 47.3 Part No.
The pressure difference generated at this time opens check valve and the residual pressure on the A port side is quickly exhausted from R port. 2 1(P) OFF 2(A) 1 3(R) 3 Soft Start-up Valve AV2000/3000/4000/5000 Construction B ON OFF B-B 1(P) 2(A) B 3(R) Parts list No. 1 2 3 Description Material Body Cap Cover ADC ADC ADC Replacement parts Description No. Part no.
M5 x 0.8 b Cv b Cv VV3Z1-01-1 VV4Z1-20-1 1/8 How to Order Manifold Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with the manifold base model no.