-2 2.3 Function of Parts . 2-3 2.4 Operation display panel . 2-4 Chapter 3 Transport and Setting Up . 3-1 3.1 Transport. 3-1 3.1.1 Transportation using casters . 3-2 3.2 Installation . 3-3 3.2.1 Environment . 3-4 3.2.2 Location (Required ventilation rate and facility water source) . 3-6 3.2.3 Installation and Maintenance Space . 3-7 3.3 Installation . 3-8 3.3.1 Mounting . 3-8 3.3.2 Electrical
O31..O16 0 AI2 AO4 2 1 AI5 AO5 2 1 AI3 AO5 2 AI6 AO6 2 AI4 AO6 3 AI7 AO7 3 AI5 AO7 Station I47..I32 O47..O32 0 AI8 AO8 Station I47..I32 O47..O32 0 AI6 AO8 3rd division 3 1 AI9 AO9 3 1 AI7 AO9 2 AI10 AO10 2 AI8 AO10 3 AI11 AO11 3 AI9 AO11 Station System area 0 AI12 AO12 Station System area 0 AI10 AO12 4th division 4 1 AI13 AO13 4 1 AI11 AO13 2 AI14 AO14 2 AI12 AO14 3 AI15 AO15 3 AI13 AO15
Emergency display Display: Red/display the error code on Lt;;D Pressure display 3 1/2 Digit LCD Se ~ diagnosIs functIOn Excess pressure/Data error/ NoIe2) Excess current/Pressure during O-clear Operating temp.range O~50 'C I Bottom mode Noise resistance 500Vp~p pulse width 1 itS standing 1 nS fbl/nn lULl Insulation resistance Between whole wires and case 2M Q (SOVDC by megameter) Vibration
error occurred. -67No.EX-OMQ0016 Unit diagnostic status 0 7 6 5 4 3 2 1 0 Byte 2 Bit No.
, 3: 0..10V (default) , 4: 0..5V, 5: 1..5V, 6: 0..20mA, 7: 4..20mA 01h Channel 0 .. .. .. 300Bh Slot0_AnalogRange 0: -10..+10V, 1: -5..+5V, 2: -20..+20mA, 3: 0..10V (default) , 4: 0..5V, 5: 1..5V, 6: 0..20mA, 7: 4..20mA 04h Channel 3 00h NumberOfEntries 4 01h Channel 0 0: None, 1: 2 value (default) , 2: 4 value, 3: 8 value .. .. .. 300Ch Slot0_AnalogFilter 04h Channel 3 0: None, 1: 2 value
Signal name 1 24 V (Output) 2 0 V (Output) 3 24 V (Control and input) 4 0 V (Control and input) 5 F.E. (2) EX600-ED3Configuration Pin No.
center (A) 4 (A) 4 (B) 2 (B) 2 2 position single Pilot pressure range (MPa) 2 position double 3 position 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) Ambient and fluid temperature (C) 3 position pressure center (A) 4 (B) 2 Not required Lubrication Free 300/50 Mounting position Impact/Vibration resistance (m/s2) (1) 1 (P) 5 (R1) 3 (R2) Base monted Note 1) Impact resistance: No malfunction resulted
closed center 3 position exhaust center 3 position pressure center 2 position single 2 position single 2 position double 3 position closed center 3 position exhaust center 3 position pressure center 2 position single 2 position double 3 position closed center 3 position exhaust center 3 position pressure center 2 position single 2 position double 3 position closed center 3 position exhaust
G1/2 3 1.0MPa 2 1/4NPT M201.5 *2 3 1/4NPT 1/2NPT Construction 4 G1/4 G1/2 0 Standard type 5 G1/4 M201.5*2 2 Output function {analog output (4-20mADC)+ alarm outputX2} 6 G1/4 1/2NPT 3 HART communication function (preparing) Accessory*1 NIL No accessory 1: If two or more accessories are required, the part numbers should be made according to alphabetical order.
Refer to front matter 56 for Safety Instructions and pages 468 to 471 for Flow Control Equipment Precautions. 0 1 G 3/8 Note 2) F03 F04 U10/32 N01 G 3/8 G 1/2 10-32 UNF NPT 1/8 NPT 1/4 Note 1) R 3/8 R 1/2 10-32 UNF NPT 1/8 N02 NPT 1/4 NPT 3/8 Note 2) N03 N04 NPT 3/8 NPT 1/2 NPT 3/8 NPT 1/2 Note 1) AS220-02 Note 2) AS320-02 614 Series AS20-T Tamper Proof Speed Controller Standard Type, Elbow
Yes 5 V A93V A93 Grommet 12 V 100 V Relay PLC 24 V 2-wire IC circuit A90V A90 5 V,12 V 100 V or less M9NV M9N 3-wire (NPN) IC circuit 5 V 12 V M9PV M9P 3-wire (PNP) M9BV M9B 12 V 2-wire Relay PLC Yes Grommet 24 V F9NWV F9NW 3-wire (NPN) Diagnostic indication 2-color display IC circuit 5 V 12 V F9PWV F9PW 3-wire (PNP) F9BWV F9BW 2-wire 12 V . . .
-12No.EX-OMQ0015CN DIN (SY SY ) (1)6 (M4X6)DIN (EX600-ZMB2) 2 EX600 0.70.8 Nm (2)M4X14EX600-ZMA22 0.70.8 Nm EX600-ZMA2 EX600-ZMB2 EX600-ZMB2 (3)DIN DIN (4)DIN (5)M4X20(EX600-ZMA2) 0.70.8Nm DIN DIN EX600-ZMA2 -13No.EX-OMQ0015CN M12 M8 M12 SPEEDCON SPEEDCON (1)(/)AB (2)C (3)B180(1/2) (1) (2) (3) A B C (EX600-ZT1) -14No.EX-OMQ0015CN SI EX600-S SI 1 /PNP 2 /NPN PN PROFINET
specification 1578078 Plug 1578081 Socket 86 27 27 86 27 27 Width across flats 24 3 3 2 2 4 4 Terminal no.
46.5 36.5 36.5 50.5 3 46.5 36.5 26.5 26.5 40.5 40.5 54.5 82.5 73.5 27 800 MXQ 1322Air Slide Table Dimensions: MXQ6 1322Basic 2 x M2.5 x 0.45 thread depth 3 2 6 Operating port 2 x M5 x 0.8 3 I J Max. 10 (Retraction end adjuster) 6 4 13.5 3.5 5.5 Note 1) If long bolts are used, they can touch the guide block and cause malfunction, etc.
DIN (SY SY ) (1)6 (M4X6)DIN (EX600-ZMB2) 2 EX600 (0.70.8 Nm) (2)(M4X14(EX600-ZMA22 (0.70.8 Nm) EX600-ZMA2 EX600-ZMB2 (3)DIN DIN (4)DIN (5)(M4X20(EX600-ZMA2) (0.70.8 Nm) DIN DIN EX600-ZMA2 6 -13No.EX-OMS0026CN M12 M8 M12 SPEEDCON SPEEDCON (1)(/)BA (2)C (3)B180(1/2) (1) (2) (3) A B C (EX600-ZT1) -14No.EX-OMS0026CN SI EX600-S EN 3 SI / 3 PNP()/2 4 NPN()/2 TM EN EtherNet
(inch) Model NPT3/8 KQGT03-00 KQGT07-00 KQGT09-00 KQGT11-00 KQGT13-00 5/32 NPT1/4 3/8 1/4 NPT3/8 5/16 NPT3/8 1/2 3/8 NPT1/2 1/2 Straight Union Straight Union Union Y Union Y Applicable tubing O.D. (inch) Model Applicable tubing O.D.
No.CG1*-OM0006N / / C*G5*N**SR/V-* C*G5*A**SR/V-* P2 P4 1. P6 1-1. 2. P7 2-1. 2-2. 2-3. 2-4. 2-5. 2-6. 2-7. 2-8. 3. P16 3-1. 3-2. 3-3. 3-4. 4. P24 5.
*1 Soft Start-up Valve AV2000-A/3000-A/4000-A/5000-A Series 2(A) Symbol How to Order (P)1 3(R) *1 CE compliant AV 00 20 02 B B 1 D q w e r t y u i o A Electrical entry Grommet DIN terminal AC V DC V V V q Body size 20 30 40 50 Symbol Description w Thread type Nil Rc V V V V N NPT V V V V F G V V V V + 02 1/4 V 03 3/8 V 04 1/2 V 06 3/4 V 10 1 V + e Port size 1(P), 2(A) a Mounting Nil
ARM 2 2 3 3 3 4 4 5 5 6 6 2 2 2 3 3 4 4 5 5 6 6 1 2 1 2 3 1 2 1 2 1 2 A B C A B A B A B A B 6 x 4 4 x 3 10 x 8 8 x 6 6 x 4 12 x 10 10 x 8 19 x 16 12 x 10 25 x 22 19 x 16 1/4" x 5/32" 3/16" x 1/8" 1/8" x 0.086" 3/8" x 1/4" 1/4" x 5/32" 1/2" x 3/8" 3/8" x 1/4" 3/4" x 5/8" 1/2" x 3/8" 1" x 7/8" 3/4" x 5/8" SMC SMC SMC ARP P U Panel mount union Union IR-A IR SMC IRV : Basic size : With reducer
angular acceleration after t seconds can be found as follows. t ( 1 ) 2 1 ( 2 ) C t tdt 2 When 0 t , rotation angle =0, so the integration constant is C=0. t t 2 1 2 1 2 thus, 2 t 28 - Auto switch type for rotary table The rotary table has a magnet mounted on its piston and an auto switch on the outside of the body to detect the piston position (table position).