Pressure: 10 MPa, Piping: G1/4, ISO1179, Output: 65 [PNP Open Collector 1 Output (Pin no.: 4)], Display Unit: Fixed SI Unit, MPa, Option 1: S [Lead Wire with M12 Connector (5m), Straight], Option 2: With Bracket

Pressure: 10 MPa, Piping: NPT1/4, Output: 65 [PNP Open Collector 1 Output (Pin no.: 4)], Display Unit: Fixed SI Unit, MPa, Option 1: S [Lead Wire with M12 Connector (5m), Straight], Option 2: With Bracket

Pressure: 15 MPa, Piping: NPT1/4, Output: 65 [PNP Open Collector 1 Output (Pin no.: 4)], Display Unit: Fixed SI Unit, MPa, Option 1: S [Lead Wire with M12 Connector (5m), Straight], Option 2: With Bracket

Pressure: 15 MPa, Piping: G1/4, ISO1179, Output: 65 [PNP Open Collector 1 Output (Pin no.: 4)], Display Unit: Fixed SI Unit, MPa, Option 1: S [Lead Wire with M12 Connector (5m), Straight], Option 2: With Bracket

Rated Flow Range: 0.1 to 10 L/min, Flow Adjustment Valve: With Flow Adjustment Valve, Straight, Port Size: ø6, Output Specification: Out 1: PNP; Out 2: PNP, Lead Wire: Lead Wire w/Connector, Unit Specification: SI Unit Only, Bracket/Panel Mount Adapter: Bracket, w/Flow Adjustment Valve, Calibration Certificate: Calibration Certificate, Made to Order: -

Rated Flow Range: 0.1 to 10 L/min, Flow Adjustment Valve: With Flow Adjustment Valve, Straight, Port Size: ø6, Output Specification: Out 1: NPN; Out 2: Analog 4 to 20 mA, Lead Wire: Lead Wire w/Connector, Unit Specification: SI Unit Only, Bracket/Panel Mount Adapter: Bracket, w/Flow Adjustment Valve, Calibration Certificate: Calibration Certificate, Made to Order: -

Rated Flow Range: 1 to 100 L/min, Flow Adjustment Valve: With Flow Adjustment Valve, Straight, Port Size: ø8, Output Specification: Out 1: NPN; Out 2: NPN, Lead Wire: Lead Wire w/Connector + Rubber Cover for Connector, Unit Specification: SI Unit Only, Bracket/Panel Mount Adapter: Bracket, w/Flow Adjustment Valve, Calibration Certificate: Calibration Certificate, Made to Order: -

Rated Flow Range: 0.5 to 50 L/min, Flow Adjustment Valve: With Flow Adjustment Valve, Straight, Port Size: ø6, Output Specification: Out 1: NPN; Out 2: NPN, Lead Wire: Lead Wire w/Connector + Rubber Cover for Connector, Unit Specification: SI Unit Only, Bracket/Panel Mount Adapter: Bracket, w/Flow Adjustment Valve, Calibration Certificate: Calibration Certificate, Made to Order: -

Rated Flow Range: 1 to 100 L/min, Flow Adjustment Valve: With Flow Adjustment Valve, Straight, Port Size: ø8, Output Specification: Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V, Lead Wire: Lead Wire w/Connector, Unit Specification: SI Unit Only, Bracket/Panel Mount Adapter: Bracket, w/Flow Adjustment Valve, Calibration Certificate: Calibration Certificate, Made to Order: -

Rated Flow Range: 0.1 to 10 L/min, Flow Adjustment Valve: With Flow Adjustment Valve, Straight, Port Size: ø6, Output Specification: Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V, Lead Wire: Lead Wire w/Connector + Rubber Cover for Connector, Unit Specification: SI Unit Only, Bracket/Panel Mount Adapter: Bracket, w/Flow Adjustment Valve, Calibration Certificate: Calibration Certificate

Rated Flow Range: 1 to 100 L/min, Flow Adjustment Valve: With Flow Adjustment Valve, Straight, Port Size: ø8, Output Specification: Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V, Lead Wire: Lead Wire w/Connector, Unit Specification: SI Unit Only, Bracket/Panel Mount Adapter: Bracket, w/Flow Adjustment Valve, Calibration Certificate: Calibration Certificate, Made to Order: -

Rated Flow Range: 0.5 to 50 L/min, Flow Adjustment Valve: With Flow Adjustment Valve, Straight, Port Size: NPT1/8, Output Specification: Out 1: NPN; Out 2: NPN, Lead Wire: Lead Wire w/Connector, Unit Specification: SI Unit Only, Bracket/Panel Mount Adapter: Bracket, w/Flow Adjustment Valve, Calibration Certificate: Calibration Certificate, Made to Order: -

Rated Flow Range: 0.5 to 50 L/min, Flow Adjustment Valve: With Flow Adjustment Valve, Straight, Port Size: ø6, Output Specification: Out 1: PNP; Out 2: Analog 4 to 20 mA, Lead Wire: Lead Wire w/Connector + Rubber Cover for Connector, Unit Specification: SI Unit Only, Bracket/Panel Mount Adapter: Bracket, w/Flow Adjustment Valve, Calibration Certificate: Calibration Certificate, Made to Order

Rated Flow Range: 2 to 200 L/min, Flow Adjustment Valve: With Flow Adjustment Valve, Straight, Port Size: ø8, Output Specification: Out 1: PNP; Out 2: Analog 4 to 20 mA, Lead Wire: Lead Wire w/Connector + Rubber Cover for Connector, Unit Specification: SI Unit Only, Bracket/Panel Mount Adapter: Bracket, w/Flow Adjustment Valve, Calibration Certificate: Calibration Certificate, Made to Order

Rated Flow Range: 2 to 200 L/min, Flow Adjustment Valve: With Flow Adjustment Valve, Straight, Port Size: 1/4, Output Specification: Out 1: PNP; Out 2: Analog 4 to 20 mA, Lead Wire: Lead Wire w/Connector + Rubber Cover for Connector, Unit Specification: SI Unit Only, Bracket/Panel Mount Adapter: Bracket, w/Flow Adjustment Valve, Calibration Certificate: Calibration Certificate, Made to Order

Rated Flow Range: 0.3 to 25 L/min, Flow Adjustment Valve: With Flow Adjustment Valve, Straight, Port Size: NPT1/8, Output Specification: Out 1: PNP; Out 2: PNP, Lead Wire: Lead Wire w/Connector + Rubber Cover for Connector, Unit Specification: SI Unit Only, Bracket/Panel Mount Adapter: Bracket, w/Flow Adjustment Valve, Calibration Certificate: Calibration Certificate, Made to Order: -

Dimensions for installation n: number of valve stations n L 1 2 3 4 5 6 7 8 L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 L2 80 96 112 128 144 160 176 n L 9 10 11 12 13 14 15 16 L1 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7 L2 192 208 224 240 256 272 288 304 (mm) The above table shows dimensions as an example for the SY5000 series valve manifold.

L2 = 21 x m + 89.8 L1 = 10.5 x n + 45 Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof. Default settings At the time of factory shipment, the product is in "Remote Control Mode" and set to "Enable DHCP".

Dimensions C D L1 L2 Fd Fc C Fn (Fc) (KF Flange) (K Flange) (CF Flange) K B J H A G A Unit: mm Model A B C D Fn Fd Fc G H J KK P.C.D.

Dimensions XMH series / Angled Valve C D L1 L2 A Fn Fc C (Fc) (CF Flange) (KF Flange) H J H B G A Unit:mm Table 5 Model A B C D Fn Fc G H J P.C.D L1 L2 XMH-16 40 100.5 38 1 30 34 17 35 18 P.C.D 27 6x4.4 XMH-25 50 114 48 1 40 26 41 21.5 XMH-40 65 162.5 66 2 55 70 41 57 30 P.C.D 58.7 6x6.6 XMH-50 70 179.5 79 2 75 52 70 35 XYH series / Straight Valve D G C C B H Fn J (KF Flange) 45 Unit: mm