SMC Corporation of America
Elite Part Number Search
Search Results "PF2D520-13-1-C"

Abnormal (19 V or less) Output area mapping Output data Offset MSB LSB MSB LSB (Word) 15 8 7 0 0 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 -45No.EX-OMX1001 Dimensions -46No.EX-OMX1001 Revision history 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL https://www.smcworld.com Note: Specifications

(see Figure 2) (1) Connection and disconnection of tube from one-touch fitting Installation of tube 1) Cut the tube perpendicularly, being careful not to damage the external surface. Use an SMC tube cutter TK-1, 2, 3 or 6.

soft nylon TAU Antistatic polyurethane 1/8 KFG201-P01 5/32 KFG203-P01 4 KFG204-P01 6 KFG206-P01 1/4 KFG207-P01 8 KFG208-P01 Bulkhead nut SUS316 5/16 KFG209-P01 10 KFG210-P01 3/8 KFG211-P01 12 KFG212-P01 1/2 KFG213-P01 16 KFG216-P01 4.

Center of gravity . 10 4.Product Specifications . 11 4-1. Air Gripper . 11 4-2. 3 Port Solenoid Valve . 12 4-3. Auto Switch . 13 5.Operating method / operation . 14 5-1. Design . 14 5-2. Installation . 14 5-3. Air supply . 20 5-4. Piping . 20 5-5. Operating environment . 20 5-6.

Byte0: Station Status 1 Bit 7 0 0 0 0 0 X 0 0 0 Diag. Station_Non_Existent 1 when SI unit is not recognized by the master Diag. Master_Lock 1 when SI unit is set as the other master Diag. Prm_Fault 1 when the parameter regarding the SI unit is wrong Diag. Station_Not_Ready 1 when the SI unit is not ready for data transmission Diag.

43 69 77 95 89 106 1 8 1 4 14 8.6 8.6 4 29 32 33 34 1 8 15.2 18 27 6 18.5 21.6 14.9 17 8 1 4 3 8 1 4 3 8 1 2 3 8 1 2 42 10 18.5 32 23.5 21 30.5 25.0 22 7 Kl 43 44 45 20.9 24 35 26 22 8 35.1 35.1 12 Ml Reference dimensions after R(PT) thread installation.

Product Specifications . 12 4-1. Air Gripper . 12 4-2. 3 Port Solenoid Valve . 13 5. Operating method / operation . 15 5-1. Design . 15 5-2. Installation . 15 5-3. URCap . 19 5-4. Air supply . 24 5-5. Piping . 24 5-6. Operating environment . 24 5-7. Lubrication . 25 6.

Option/Semi-standard symble:When more than one specification is required, indicate in alphanumeric order. 1 3 4 5 6 2 Symble Description 0.020.2MPa 0 0 0 0 Set pressure range 1 1 1 1 0.020.4MPa 2 2 2 2 0.020.8MPa + 1 Exhaust direction 0 0 0 0 Bottom exhaust + 2 Rc Nil Nil Nil Nil Pipe thread type NPT N N N N F F F F G + 3 Port size 02 02 02 02 1/4 + 4 Nil Nil Nil Nil Without pressure gauge

ZFB30 ZFFB40 05 3/16" 07 1/4" 11 3/8" 13 1/2" -7- 2-2 Specifications Specifications Remarks Fluid Air, Nitrogen Do not use the product in an atmosphere and place where there is direct contact with chemicals.

Selection 6-1 Selection Select the appropriate cylinder based on mass of transferred object and transfer speed (Fig.1). Example 1: For roller type with transfer speed of 15m/min. and the mass of transferred object of 30kg.

If you select the "Function Selection (Pn0xx-)", it will be displayed as follows. 1 2 13 - For details of each parameter, refer to LECY "Instruction Manual" and "Instruction Manual (simplified version)". 3. Please check to be written parameters of the target No.

AREA ON INP ON 9 - 4. 4.1 () () (()) Yes(Y)No(N) 5.1 10 - ID ( ) I/O I/O ON I/O ON() I/O (EMG) I/O 11 - (/) []() [] () [/] ON()OFF() NoALARM SVREBUSYINPSETON ALARM() SVRE() ON BUSY() : () INP() : SETON() ALARM ()No.0 () () 12 - 4.2 (F) (E) 1 (C) COM (S) () 13 - 4.3 2 () 4.3.1 (1) (2)SVRE (3)SETON 4.3.2 (1) (2) (3) 4.3.3.

Indoor Installation place 1 NORWAY (47) 67 12 90 20 Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof. Vollsveien 13 C, Granfos Nringspark N-1366 Lysaker, Norway No. Item Description Specification 1 Connector M8 connector for cable to Air Management Hub.

NETHERLANDS (31) 020 5318 De Ruyterkade 120, NL-1011 AB Amsterdam, the Netherlands NORWAY (47) 67 12 90 20 Vollsveien 13 C, Granfos Nringspark N-1366 Lysaker, Norway POLAND (48) 22 211 96 00 ul.

Electric linearity 1% or less for 13 to 18.5 (1 A F.S.) Fluctuation to impedance 1% or less for 22 to 26 VDC (1 A F.S.) Fluctuation to power supply 2% or less for 25C 25C (1 A F.S.)

Auto Switch Groove Position D-A, D-A9V W D-M9, D-F9W A D-M9V, D-F9WV W Bore size (mm) Application B B A W A B stroke 6 5 to 30 3.5 0 17 6.5 13 3.5 2.5(5) 17 4.5 5 to 20 17 13 17 10 25 7.5 3.5 20 16 2.5 7.5 20 1.5 0.5 30 19 15 19 (1) 5 27 23 27 10 22 18 22 15 27 23 27 16 8 4 2 8 2 0 B A 20 22 18 22 Bore (mm) 6 10 16 25 27 23 27 (0.5) 6.9 10 30 27 23 27 8.8 14 13.9 19 Note 1) Negative figures

Auto Switch Groove Position D-A, D-A9V W D-M9, D-F9W A D-M9V, D-F9WV W Bore size (mm) Application B A B B W A stroke 6 5 to 30 0 13 3.5 3.5 6.5 17 2.5(5) 17 4.5 5 to 20 13 17 17 10 25 3.5 16 7.5 7.5 2.5 20 1.5 20 0.5 30 15 19 (1) 19 5 23 27 27 10 18 22 22 15 23 27 27 16 4 8 8 2 2 0 A B 20 18 22 22 Bore (mm) 6 10 16 25 23 27 27 (0.5) 10 6.9 30 23 27 27 14 8.8 19 13.9 Note 1) Negative figures

55 mA or less (at no load) Switch output NPN or PNP open collector output: 1 output ISE70 Max. load current 80 mA Max. applied voltage 30 V (With NPN output) ZSE80 ISE80 Residual voltage 1 V or less (With load current of 80 mA) PS Response time 1 s (0.25, 0.5, 2, 3s selections) Short circuit protection Yes ISA3 1% F.S.