push style 4 1 (P) 5 (R1) 3 (R2) 5 (R1) 3 (R2) 1 (P) VP4 2 2 position double 3 position pressure center (A) 4 (B) 2 (A) 4 (B) 2 5 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) VQ 3 position double check (A) 4 (B) 2 6Note) VQ4 Light and surge voltage suppressor 1 (P) 5 (R1) 3 (R2) E With W/o light/With surge suppressor VQZ Note) Refer to p.1.11-36 for double check style.
Body material ZNC 80 Nil 80 70 27.5 17 74 84 M5 x 0.8 10 17 2.5 20 2 8.5 1.0 8.3 12 3 5 1 5.8 15.2 1.0 193 P 119 S 568 *1 The stopper, vibration suppression cover, and plug weights are not included. 14 ZNC Series Specific Product Precautions 1 Be sure to read this before handling the products. Design / Selection Mounting 1.
1 20 400 10 70 0.01 2 40 6000 100 40 0.1 3 90 1000 20 1 4 10 +3 5 5 10 +7 6 0 < Cp 5 +10 7 5 < Cp 10 Cw 0.5 8 0.5 < Cw 5 9 5 < Cw 10 x Cp > 10 Cw > 10 > 5 [How to Perform a Test to Check the Performance] ISO 12500, which sets out the test method to be used in order to check the filter performance for each of the three kinds of contaminants, is indicated
Without brake C section details Cross section BB l\rodel D F L 1 5 4 231 LXPB B-50 L X P B B . 7 5 173 256 52 L X P B _ B _ 1 0 0 204 281 246 323 LXPB B -.125 L X P B B 1 5 0 271 348 120 90 L X P B _ B _ 1 7 5 296 373 LXPB_B_-200 321 394 ?$rc zs S8[i8$ [10 Camraclnectl' 0i|llomiom $lift $crExi tlE LXPB S With brake I I shows the localion at which origin point swiich operates.
Flow Rate and Sonic Conductance AS121F-M3 AS121F-M5 AS131F-M5 AS221F-01 AS231F-01 AS221F-02 AS231F-02 AS321F AS331F AS421F AS431F AS131F-M3 Model AS121F-M5-02 2, 3.2, 4 3.2, 4, 6 3.2, 4 6, 8, 10 8, 10 4 6 6 8 10 12 10, 12 Metric size Tubing O.D. 1/8" , 3/16" 1/8" , 5/32" 1/8" , 5/32" 3/16" , 1/4" , 1/4" , 5/16" , 3/8" 1/4" Inch size 5/32" 3/16" 5/16" 3/8" 1/2" 1/4" , 5/32" 5/16" 3/8" Controlled
5 !0 !4 o i q !3 e r !2 !1 u t w y CHK CHN CHM CHM CHS CH2 o !
Panel adapter B ZS-22-02 Thread type Piping port size Rc NPT G Nil N F 01 02 1/8 1/4 Specifications PFA301-m PFA300-m Model Specifications Note 1) 1 to 10, 5 to 50l/min (0.04 to 0.35, 0.18 to 1.77SCFM) Flow rate range measurement & setting Minimum setting unit 1% of maximum flow rate range Model PFA510-m PFA550-m Real-time flow rate l/min, CFM x 10-2 Display units Measured fluids Dry air,
Port size Body size 2 to 16 1 to 4 M5 to 1/2 1/8" to 1/2" Metric size Inch size 2 to 16 1 to 4 M5 to 1/2 1/8" to 1/2" Flow rate 0 5 10 Number of needle rotations Refer to the Web Catalog for details.
. 3-7 Chapter 4 Operation/ Shutdown . 4-1 4.1 CHECK POINTS BEFORE OPERATION . 4-1 4.2 OPERATION . 4-1 4.3 STOP . 4-2 4.4 CAUTIONS FOR RE-START . 4-2 4.5 CHECK POINTS BEFORE RESTART. 4-2 4.6 CAUTIONS WHEN THE PRODUCT IS SHUT DOWN FOR AN EXTENDED PERIOD OF TIME . 4-2 Chapter 5 Checks and Maintenance . 5-1 5.1 DAILY INSPECTION . 5-1 5.2 REGULAR MAINTENANCE . 5-2 5.2.1 Clean the dustproof filter
side bracket Series SYA5000 One-touch fitting for 6 One-touch fitting for 8 One-touch fitting for 8 One-touch fitting for 10 3 SYA3000 5 SYA5000 SYA7000 7 SYA7000 SYA 5 1 C6 20 Body ported 40 SYA 5 1 Base mounted P, R port thread type Series 3 SYA3000 5 SYA5000 Rc Nil G F 40 SYA 7 1 Base mounted N NPT NPTF T P, R port thread type Type of actuation Rc Nil 2 position single G F Port size 1
mm/s Piston speed mm/s Piston speed mm/s (4) CY1F/m1 (5) CY1F/m2 (6) CY1F/m3 (7) CY1F/m4 30 30 30 30 20 20 20 20 CY1F25 CY1F25 CY1F25 CY1F25 10 10 10 10 CY1F15 CY1F15 CY1F15 5 5 5 5 Load mass kg Load mass kg Load mass kg Load mass kg 4 4 4 4 3 3 3 3 CY1F15 CY1F10 CY1F10 CY1F10 2 2 2 2 CY1F10 1 1 1 1 0.5 500 300 100 50 0.5 500 300 100 50 0.5 500 300 100 50 0.5 500 300 100 50 Piston speed mm
9 #1 !6 @9 r MTS $0 #6 MY A' CY $1 !1 !2 !0 !8 w $4 t e $2 !5 $3 y!7 @8 !4 !
16 1 (Rod cover side) 2 (Different sides) 2 (Same side) Number of auto switches D-H7BAL 5 CY Since this is a guideline including hysteresis, not meant to be guaranteed.
16 1 (Rod cover side) 2 (Different sides) 2 (Same side) Number of auto switches D-H7BAL 5 CY Since this is a guideline including hysteresis, not meant to be guaranteed.
(at 80 mA load current) Response time *5 *7 0.25 s/0.5 s/1 s/2 s/5 s Outputprotection Short circuit protection Output Mode Select from Hysteresis mode, Window comparator mode, Accumulated output mode or Accumulated pulse output mode Response time*6*7 0.25 s/0.5 s/1 s/2 s/5 s Analogue output Voltage output Output voltage: 1 to 5V (Output impedance approx. 1k) Current output Output current
Refer to pages 12-10-4 to 12-10-5 for the details on effective holding force and allowable overhanging distance. Misc. D2012-10-9 9 Series MHY2 Construction Closed condition Size 10 Size 16 Size 20, 25 r o !8 e w !7 t r o !8 e w @0 !7 t r o !8 e w @0 !7 t !5 !5 !5 !6 !6 !0 u !2 i q !1 y !9 !0 u !2 i q !1 y !9 !0 u !3 !2 i q !1 y !9 !4 !4 !
Refer to pages 12-10-4 to 12-10-5 for the details on effective holding force and allowable overhanging distance. Misc. D2012-10-9 9 Series MHY2 Construction Closed condition Size 10 Size 16 Size 20, 25 r o !8 e w !7 t r o !8 e w @0 !7 t r o !8 e w @0 !7 t !5 !5 !5 !6 !6 !0 u !2 i q !1 y !9 !0 u !2 i q !1 y !9 !0 u !3 !2 i q !1 y !9 !4 !4 !
(PNP) M9PAV*1 M9PA*1 M9PAV*1 M9PA*1 v v V v v 2-wire 12 V M9BAV*1 M9BA*1 M9BAV*1 M9BA*1 v v V v v Grommet Water resistant (2-color indication) With diagnostic output (2-color indication) 4-wire (NPN) 5 V,12 V H7NF F79F V V v v IC circuit 3-wire (NPN equivalent) 5 V A96V A96 A96V A96 V V IC circuit Reed auto switch Yes 200 V A72 A72H V V Grommet 100 V A93V*2 A93 A93V*2 A93
40 40 50 P1 = 1 MPa P1 = 0.8 MPa P1 = 0.6 MPa 30 30 Example 2 20 20 P1 = 0.5 MPa P1 = 0.4 MPa Example 1 10 10 P1 = 0.3 MPa P1 = 0.2 MPa 4 5 5 4 P1 = 0.1 MPa 3 3 2 2 1 1 0.001 0.01 0.1 0.002 0.003 0.02 0.03 0.04 0.004 Pressure differential P [MPa] Graph (2) Flow rate characteristics Example 1) Obtain the pressure difference when water [15 L/min] runs through the solenoid valve with a Kv =
[N] 47 78 157 72 108 216 75 113 225 Power consumption [W]*8 5 5 5 Rated voltage [V] 24 VDC 10% *1 Speed changes according to the work load.