If the fluid temperature is 5C or less, the moisture in the circuit could freeze, causing damage to the seals or equipment malfunction. Therefore, take appropriate measures to prevent freezing. For compressed air quality, refer to the SMC Best Pneumatics No. 6 catalog. 5.

Clean Exhaust Filter SFE Series RoHS How to Order SFE 11 Size/Port size Male thread type Plug-in type Symbol Port size Max. ow capacity L/min (ANR) 11 M5 x 0.8 3 42 R1/8 65 52 R1/8 130 53 R1/4 130 73 R1/4 200 Symbol Port size Max. ow capacity L/min (ANR) 3A 4 30 4B 6 65 5C 8 130 7D 10 200 Male thread type One-touch tting type Symbol Applicable tubing O.D.

2 Aluminum Diffuser t Stainless steel Needle y Aluminum Spool u Resin Piston i 13-8-11 12 Series ZYY/ZYX Exhaust Characteristics/Flow Characteristics The flow rate characteristics correspond to a supply pressure of 0.45 MPa.

Take measures to prevent freezing, since moisture in circuits can be frozen under 5C, and this may cause damage to seals and lead to malfunction. Refer to SMCs Air Cleaning Equipment catalog for further details on compressed air quality. Piping Caution 1.

Take measures to prevent freezing, since moisture in circuits will be frozen under 5C, and this can cause damage to seals and malfunction. Refer to SMCs clean pneumatic series Air Cleaning Equipment catalog for further details on compressed air quality. Operating Environment Warning 1. Do not use in environments where there is a danger of corrosion.

Take measures to prevent freezing, since moisture in circuits will be frozen under 5C, and this can cause damage to seals and malfunction. Refer to SMCs clean pneumatic series Air Cleaning Equipment catalog for further details on compressed air quality. Operating Environment Keep the instruction manual where it can be referred to as needed. Warning 1.

Take measures to prevent freezing, since moisture in circuits will be frozen under 5C, and this can cause damage to seals and malfunction. Refer to SMCs clean pneumatic series Air Cleaning Equipment catalog for further details on compressed air quality. Operating Environment Keep the instruction manual where it can be referred to as needed. Warning 1.

If the fluid temperature is 5C or less, the moisture in the circuit could freeze, causing damage to the seals or equipment malfunction. Therefore, take appropriate measures to prevent freezing. For compressed air quality, refer to the SMC Best Pneumatics No. 6 catalog. 5.

Chamfered port size D (Recommended value) Rc, G NPT, NPTF Female thread size 1 8 1 4 3 8 1 2 10.5 to 11.8 14.1 to 15.8 17.4 to 19.4 21.7 to 25.1 10.2 to 11.8 13.6 to 15.8 17.1 to 19.4 21.4 to 25.1 15-1-11

Auto preset (page 11) Automatically sets the pressure value. Although supply pressure for each channel is the same, slightly different values are displayed. Displays exact the same pressure values for all channels. kPa MPa Auto identification function (page 14) Can automatically identify the pressure range of a connected SMC sensor.

Tightening torque (Nm) 0.5 to 0.7 Nominal thread size M3 11 Digital Pressure Switch Precautions 2 Be sure to read before handling. Air Supply Selection Warning Warning 1. Use the switch within the operating fluid and ambient temperature range.

VlA Selection Caution Environment Warning VM/VR VH q Use in low temperature environments The valve can be used at a temperature down to 5C. Take appropriate measures to avoid freezing of drainage, moisture, etc. q When the valve is installed in an atmosphere where there is a lot of dust, install a silencer into the port "3(R)".

1.41 0.41 1.07 0.46 1.32 0.52 1.33 0.51 1.71 0.28 0.82 0.34 1.07 0.23 0.81 0.19 0.49 335 LLB Series Specifications Model LLB3 LLB4 Clean Air Module Common Specifications Fluid Clean air, N2 gas (Inlet air conditions: equivalent to ISO 8573-1 and Quality Class 1.4.1-1.6.1) Note 3) Maximum operating pressure 0.7 MPa Set pressure 0.05 to 0.4 MPa Withstand pressure 1.0 MPa Fluid temperature 5C

Take measures against freezing when operating at 5C or less. Mounting and Adjustment Caution 1. Do not drop or bump. Do not drop, bump or apply excessive impacts (980 m/s2 or more for sensor unit and 98 m/s2 or more for amplifier unit) while handling.

Ambient and fluid temperature operation is as follows: Digital pressure switches: 0 to 50C Take measures to prevent moisture from freezing in circuits when below 5C, since this may cause damage to the O-ring and lead to a malfunction. The installation of an air dryer is recommended for eliminating condensate and moisture.

Port R Operating Fluid and Ambient Temperature Operating fluid temperature (C) (3) Vacuum Ambient temperature (C) Temperature conditions Air (Standard) Oil (Standard) (V) Port P Port A Maximum Minimum 60 5 (1) 40 5 40 40 5 5 (2) Note 1) Dew point: 5C or less Note 2) 500 cSt or less Note 3) V in parentheses is option symbol. Option Material No.

Specification: Standard Type (Not Clean Room), Bore Size: 4.5 mm, Symmetric Type: Symmetric, Stroke: 5mm, Adjuster: Metal Stopper Both Ends, Function: -, Switch Rail: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Specification: Standard Type (Not Clean Room), Bore Size: 4.5 mm, Symmetric Type: L (Symmetric), Stroke: 5mm, Adjuster: C (Metal Stopper Both Ends)

Specification: Standard Type (Not Clean Room), Bore Size: 4.5 mm, Symmetric Type: Symmetric, Stroke: 5mm, Adjuster: Metal Stopper Both Ends, Function: w/o Axial Piping, Switch Rail: w/Magnet & Switch Rail, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Specification: Standard Type (Not Clean Room), Bore Size: 4.5 mm, Symmetric Type: Symmetric, Stroke: 5mm, Adjuster: Metal Stopper Both Ends, Function: w/o Axial Piping, Switch Rail: w/Magnet & Switch Rail, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: -, Number: -