Kit (Terminal block) L Kit (Lead wire) M Kit (Circular connector) q SV e SYJ t t SZ VF VP4 VQ 1/2 y VQ 4/5 Corresponding kit S(EX600, EX250, EX126), F, P, T @0 VQC 1/2 !
y q, w, t, y t Hexagon socket head plug r Plate mounting bolt MB Specifications and external dimensions other than above are the same as standard type.
Stations Note 1) K T Kit S Kit With name plate Note 2) (available for T Kit only) TD0 1 to 10 (20) Terminal block box kit The maximum number of stations differs depending on the electrical entry.
How to Order 25 100 B 2 S A1 S2 w e r t u y i o !0 !
(Common with Series VZ) Sub-plate and base gasket part no. 2 4 Valve size VEX1 1 9 P VEX4 2A P Port size Thread type Thread type Port size Thread type Thread type Port size Symbol Port size Symbol Symbol Nil Symbol Nil Sub-plate A B 1/8 1/4 A B C 1/8 3/8 1/2 Rc G NPT NPTF Rc G NPT NPTF F N T F N T VEX4 4 VEX1 11 2 Base gasket Caution Refer to front matters 58 and 59 for Safety Instructions
PNP2 PF3W7--B(T)Max.28 V80 mA 1 V Max.80 mA 1.5 V NPN PF3W7--C(T)NPN PF3W7--D(T)PNP PF3W7--E(T)PNP PF3W7--F(T)Max.80 mA 1.5 V E15 V 1 k F420 mA 12 V 300 24 V 600 Max.28 V80 mA 1 V C15 V 1 k D420 mA 12 V 300 24 V 600 NPN PF3W7--GPNP PF3W7--HMax.28 V80 mA 1 V 30 ms Max.80 mA 1.5 V 30 ms -22No.PF-OMM0004-D NPN2 PF3W7--A(T)NPN PF3W7--C(T)PF3W7--D(T)NPN PF3W7--GPNP2 PF3W7--B
VQC4000 Thread type Note) VVQC4000-3A-1 Series Nil F T Rc G NPT/NPTF Kit type 1 2 4 Thread type VQC1000 VQC2000 VQC4000 Nil F T 1 2 3 Rc G NPT/NPTF S (EX240) kit F, P, T, S (EX250) kit L, M, S (EX500) kit Note) VQC 4000 thread port only Note) Tie-rods (2 pcs.) for additional stations included. U-side end plate assembly !8 U-side end plate assembly part no.
VVPA4 5 0 04 04 1 Thread type Nil Rc G NPT NPTF VP 5 port Air operated manifold F N T 5 Base size Rc A, B Port size Rc 3 4 6 1 VVPA450 Symbol 04 Port size VVPA460 1 2 3 4 Mixed 1 06 10 M (2) Piping Note 2) In the case of mixed specifications, indicate M and specify port location sparately on a manifold specification sheet.
Model (L) 3 E J M H W ( T ) L N LQ1F41 LQ1F42 LQ1F51 LQ1F52 LQ1F61 LQ1F62 12 10 19 12 25 19 60 53 34 SMC 30 12 33.1 28 21 65.2 58 (M) W N J SMC 58 41 36 14 40 32 26 3/4 19 63.2 (E) (T) H 69 51 81.5 36 14 49 39.5 Class 4, 5 JIS 10K flange Inch sizes H Applicable tubing O.D.
Re ~ t~ur.:.: n:.' s~pr~i::ng !'...-__-I___ _ P :.
Construction Component Parts Description No. q w e r t y u i o !0 !1 !
No. of sta. occupied, 2 stations T unit Can be connected with PLC I/O card for serial transmission.
(Normally open) B Port size Rc (Nominal size) VP3145 VP3165 VP3185 Symbol 03 (10A) 3 8 (15A) 1 2 (20A) 3 4 (25A) 1 Electrical entry 04 CE-compliant 06 10 12 14 20 TL D T G Grommet Conduit terminal DIN terminal Conduit terminal with indicator light SYJ (32A) 1 4 1 (40A) 1 2 1 VQZ TS (50A) 2 Symbol Internal pilot
81 50 PF3W520--T 89 54 PF3W540--T 109 71 PF3W511--T 135 92 PF3W521--T 115 74 PF3W521-F12-T 119 76 PF3W521-F14-T 123 78 -43No.PF-OMN0010-J PF3W504/520/540 (With flow adjustment valve) Basic type and flow adjustment valve Symbol A AA B D F K L N P Q Q: Number of rotations Model PF3W504S 104 50 63.6 (Max. 68.6) 70.2 34 58.5 18 13.6 2.7 depth 10 19 6 turns PF3W520S 112 54 63.6 (Max. 68.6) 74.2
(Refer to the figure-1.) 4) Remove the cable gland r, plain washer t and rubber seal y.
Q = T x L x x C 860 Q = T x L x x C 60 x 1000 6.0 x 1.2 x 1.80 x 103 x 0.23 860 = 6.0 x 20 x 1.80 x 103 x 0.96 x 103 = = 3.5 kW 60 x 1000 Cooling capacity = Considering a safety factor of 20%, 3.5 x 1.2 = 4.2 kW = 3456 W = 3.5 kW Cooling capacity = Considering a safety factor of 20%, 3.5 x 1.2 = 4.2 kW Circulating equipment T2: Return temperature Customers equipment L T = T2 T1 T1: Outlet
T unit Can be connected with PLC I/O card for serial transmission.