SMC Corporation of America
Elite Part Number Search
Search Results "25A-PF3W740-04-A-M"

Series: 25A-PF3W7, Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: Rc, Port Size: 1/2, Output Specification/Temperature Sensor: Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C,

Series: 25A-PF3W7, Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: Rc, Port Size: 1/2, Output Specification/Temperature Sensor: Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: NPN; Temperature Sensor: Yes, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: -

Series: 25A-PF3W7, Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: w/Flow Adjustment Valve, Thread: Rc, Port Size: 1/2, Output Specification/Temperature Sensor: Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: NPN; Temperature Sensor: Yes, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: -

Series: 25A-PF3W7, Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: w/Flow Adjustment Valve, Thread: Rc, Port Size: 1/2, Output Specification/Temperature Sensor: Out 1: NPN; Out 2: Flow Rate: NPN; Temp.: NPN; Temperature Sensor: Yes, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: -

DIN * D * I/O [m] D D 1.5 3 5 1 3 5 25 16 25 16 32 32 LECP6 LECP1 LECPA DC24V DC24V LECA6 6 N * PNP NPN PNP NPN PNP NPN LECP6/LECA6 ( ) 6 P [mm] 1 * 1 N * LECP1 [mm] 1 * * LEY 32 LEY 25 LEY16 LEY16 LEY 25 LEY 32 ( ) 1 P A * * 6 12 A N 5 10 8 16 30 LECPA A P * A * ( ) ( ) 4 3 2.5 500 [m] 1 * * * * C * B * A * 8 * 20 15 10 8 1.5 1 3 5 2 2 3 5 1 2 *

Furthermore, if the cable length exceeds 5 m, then it will decrease by up to 10% for each 5 m. (At 15 m: Reduced by up to 20%) Note 7) A reference value for correcting an error in reciprocal operation. Note 8) Impact resistance: No malfunction occurred when the actuator was tested with a drop tester in both an axial direction and a perpendicular direction to the lead screw.

Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Warning: Danger : Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.

Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water.?The PF3W series has been improved both in design and operating performance?over the PF2W flow switch.? Depending on the selected model, the PF3W is?up to 40% smaller in volume, offering improved piping space and flexibility.?

SUP block plate VVQ2000-16A EXH block plate VVQ2000-19A Port plug Note 1) A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B A B C4 (N3) With 4 (5/32") One-touch fitting Side port Cylinder port sizes Fill out in case of mixed sizes (CM/LM/NM).

(Note 1) According to this formula, multiply the following values by the piping length (□m) to get the piping resistance.
Approx. 0.0035 MPa/m for a port size 15A thermo-chiller (Note 2), approx. 0.0026 MPa/m for a port size 20A thermo-chiller (Note 2), and approx. 0.0022 MPa/m for a port size 25A thermo-chiller (Note 2). However, SMC does not design or install piping systems.

Body Size: 1/2, Thread: Rc, Port Size: 1/2, Mounting: w/o Mounting, Flow Direction: Left to Right, Pressure Unit: Name Plate and Caution Plate for Bowl in SI Units: MPa

Series: AFM, Body Size: 40, Thread: Rc, Port Size: 1/2, Mounting: w/o Mounting Option, Flow Direction: Left to Right, Pressure Unit: Name Plate and Caution Plate for Bowl in SI Units: MPa

Body Size: 3, Set Pressure: 0.01 to 0.8 MPa, Exhaust Direction: Bottom Exhaust, Thread: Rc, Port Size: 1/2, Mounting: w/o Mounting Option, Flow Direction: Left to Right, Knob: Upward

Series: AFD, Body Size: 40, Thread: Rc, Port Size: 04 (1/2), Mounting: w/o Mounting, Flow Direction: Left to Right, Pressure Unit: Name Plate and Caution Plate for Bowl in SI Units: MPa

Body Size: 3, Set Pressure: 2 (0.01 to 0.8 MPa), Exhaust Direction: 0 (Bottom Exhaust), Thread: Rc, Port Size: 04 (1/2), Mounting: w/o Mounting Option, Flow Direction: Left to Right, Knob: Upward

Series: AFM, Body Size: 40, Thread: Rc, Port Size: 04 (1/2), Mounting: w/o Mounting Option, Flow Direction: Left to Right, Pressure Unit: Name Plate and Caution Plate for Bowl in SI Units: MPa

Body Size: 40 (1/2), Thread: Rc, Port Size: 04 (1/2), Mounting: w/o Mounting, Flow Direction: Left to Right, Pressure Unit: Name Plate and Caution Plate for Bowl in SI Units: MPa

Devise a safe system so that if a person engages the emergency stop, or if a safety device is tripped during a system malfunction such as a power outage, the movement of the cylinder will not cause a hazard to humans or damage the equipment. Avoid synchronized operation using cylinders only.

Rated Flow Range: 102 (10 to 1000 L/min), Thread Type: Rc, Port Size: 04 (1/2), Output Specifications: A (Out 1: NPN; Out 2: NPN), Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: M (SI Unit Only)

Rated Flow Range: 10 to 1000 L/min, Thread Type: Rc, Port Size: 1/2, Output Specifications: Out 1: NPN; Out 2: NPN, Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: SI Unit Only, Option 2: -, Calibration Certificate: -