SMC Corporation of America
Elite Part Number Search
Search Results "53-SY5120-LL6-C4-F2"

C4/C6 One-touch fitting C4/C6 One-touch fitting (elbow type) Outstanding seal performance The new rubber seals offer improved durability and performance. Valve failures due to line contaminants have been greatly reduced. (Ozone resistant seals available by special order.)

Specifications are the same as those on pages 3.5-53 through 3.5-74. Specifications are the same as those on pages 3.19-7 and 3.19-22. Refer to pages 2.3-3 through 2.3-17. Specifications are the same as those on pages 1.4-4 and 1.4-31. Specifications are the same as those on pages 3.20-3 and 3.20-10.

(The standard valve has an individual exhaust for the pilot valve.) 4-14-40 41 Series VQZ Replacement Parts Base Mounted One-touch Fitting Assembly (For cylinder port) C3 C4 C6 C8 C10 Fitting size M5 (VQZ100 only) Model VQZ100 VVQ1000-50A-C3 VVQ1000-50A-C4 VVQ1000-50A-C6 VVQ1000-50A-M5 V100 VQZ200 VVQ1000-51A-C4 VVQ1000-51A-C6 VVQ1000-51A-C8 VQZ300 VVQ2000-51A-C6 VVQ2000-51A-C8 VVQ2000-51A-C10

Size and weight reduced by eliminating the manifold base C4/C6 One-touch fitting C4/C6 One-touch fitting (Elbow type) SZ3000 Series Height 31% reduction (Compared with SX3000-45 with DIN rail manifold and 5 stations) FREE LOCK Weight 12% reduction M5 port block assembly A port 1-3-1 B port 2 Series SZ3000 Precautions 1 Be sure to read before handling.

Size and weight reduced by eliminating the manifold base C4/C6 One-touch fitting C4/C6 One-touch fitting (Elbow type) SZ3000 Series Height 31% reduction (Compared with SX3000-45 with DIN rail manifold and 5 stations) FREE LOCK Weight 12% reduction M5 port block assembly A port 1-3-1 B port Series SZ3000 Precautions 1 Be sure to read before handling.

One-touch fitting type) VFN n: Stations L Stations 2 53 62 3 70 79 4 87 96 5 104 113 6 121 130 7 138 147 8 155 164 9 172 181 10 189 198 11 206 215 12 223 232 13 240 249 14 257 266 15 274 283 16 291 300 Formula 17n + 19 17n + 28 L1 L2 With attachment plug lead wire: VV5ZS2-51GStation 1Port size 4-4.5 mounting hole Manual override Indicator light U side (n) (2) (1) Stations D side 2-C4, C6

Bracket B Bracket assembly 16-2-53 10 Series ISE70/75/75H Specific Product Precautions 2 Be sure to read before handling. Set pressure range and rated pressure range Caution 1. Set the pressure within the rated pressure range. The set pressure range is the range of pressure that is possible in setting.

Summary of Product parts 13 Definition and terminology 14 Mounting and Installation 16 Installation 16 Piping 19 Wiring 21 Outline of Settings [Measurement mode] 25 Flow Setting (set value only) of OUT1 OUT2 [3 step setting mode] 26 Default settings 28 Function Setting [Function selection mode] 28 Default settings 28 F0 Reference condition Unit selection function 29 F1 Setting of OUT1 31 F2

Mass (g) Applied retaining ring 40 60 70 130 Df8 L d l m t -X HY-E03SUS HY-E04SUS HY-E05SUS HY-E06SUS 32 40 50 63 10 12 12 16 53 60 68 78 9.6 11.5 11.5 15.2 46 53 61 71 2.3 2.3 2.3 2.3 1.2 1.2 1.2 1.2 C type for shaft 10 Df8 d C type for shaft 12 Individual -X C type for shaft 12 t l t C type for shaft 16 L Technical data Note 1) One clevis pin is attached with two retaining rings.

Allowable Driving Force Table (Fn) (n=1,2,3) F1 = x (W + WB) x 9.8 Horizontal F2 = (W + WB) x 9.8 x (COS + SIN) Inclined (Refer to page 1466 for the maximum load weight when loaded directly on the body and connection bracket.) F3 = (W + WB) x 9.8 x ( + 1) Vertical Refer to the allowable driving force table for the (Fn) of data K A .

U side 1 2 3 4 5 n Direct manual override (Non-locking) 2n x C4, M5 4(A), 2(B) port C4: One-touch fitting for 4 M5: M5 thread 2(B) 2(B) 27.5 20 15 4(A) 4(A) 5 P = 11 12.5 (46) L plug connector (L) n: Stations Dimensions n L 11 138 130 10 127 119 L1 L2 2 39 31 3 50 42 4 61 53 5 72 64 6 83 75 7 94 86 8 105 97 9 116 108 12 149 141 13 160 152 14 171 163 15 182 174 16 193 185 17 204 196 18 215

Actuation: 2 (2-Position Double), Electrical Entry: LL (L-type Plug Connector w/Cover), Lead Wire Length: 6 (600mm, Maximum Length for L-type), Manual Override: Non-locking Push Type, A,B Port: C4 (ø4 One-touch Fitting, Metric)

Actuation: 2-Position Double, Electrical Entry: L-type Plug Connector w/Cover, Lead Wire Length: 600mm, Maximum Length for L-type, Manual Override: Non-locking Push Type, A,B Port: ø4 One-touch Fitting, Metric, Thread Type: -, Bracket: -

C4, C6, M5 C3: One-touch fitting ass'y for 3.2 C4: One-touch fitting ass'y for 4 C6: One-touch fitting ass'y for 6 C6: One-touch fitting ass'y for 6 45.5 2.5 M5: M5 thread M5: M5 thread 10.5 (5) 21.5 Dimensions Equation L1 = 11n + 20 n: Station (Max. 24 stations) 7.5 L n 1 2 3 4 5 6 7 8 11 9 10 12 29 18 31 42 53 64 75 86 97 108 141 L1 L2 L3 119 130 152 50 62.5 75 87.5 100 112.5 125 125 162.5

57 2 position C4 Single Double 68 75 132 135 158 2 position ( ) ( ) 4 One-touch fitting C8 SY360--C4 Double Closed center 148 155 201 3 position 8 One-touch fitting Closed center SY760--C8 Exhaust center 70 78 3 position Exhaust center Pressure center Single 156 163 209 Pressure center 49 53 2 position C6 Double 64 71 117 121 144 2 position Single C10 ( ) 6 One-touch fitting Closed center

No.LFE*-OMY0008 / / / / / / / / LFE# SMC SMC SMC SMC 2 11 13 14 16 18 19 21 24 26 26 F1 OUT1 28 F2 OUT2 36 F3 40 F10 41 F20 45 F22 46 F30 47 F32 48 F33 50 F34 51 F80 52 F81 53 F82 54 F90 55 F98 56 F99 57 58 60 61 64 66 67 70 71 1 No.LFE*-OMY0008 (ISO/IEC) (JIS) 1 2 1) ISO 4414:Pneumatic fluid power -General rules relating to systems.

, C6, M5 C3: One-touch fitting for 3.2 C4: One-touch fitting for 4 C6: One-touch fitting for 6 M5: M5 threads Broken lines indicate DIN rail mount type [-D] and connector top entry [-JU].

4.6 9.5 14 56 38 2.5 depth 8.5 2.6 Approx. 70g LFE38 62 53 4.6 3.5 20 68 43 2.5 depth 8.5 2.6 Approx. 70g -71No.LV50***-OMQ0002-G Dimension of the cable with M12 connector lead wire (LFE-1-A3) 4 Black Blue 3 White 2 1 Brown -72No.LV50***-OMQ0002-G Revision A : Contents revised in several places.

Save the displayed waveform screen (print screen). -53- 6.10 Display All Monitor List The method how to obtain the electric actuator condition is described with the display all function of the setup software. Click Monitor Display All of the setup software to display Display All window. The condition of each item is displayed.

When monitor command "Read alarm history" is sent to the controller with controller ID: 1 Transmission data to be used in the checksum calculation "0", "1", "0", "3", "0", "6", "0", "0", "0", "0", "0", "4" (i) 01h + 03h + 06h + 00h + 00h + 04h = 0Eh (ii) FFh 0Eh = F1h (iii) F1h + 01h = F2h Checksum = "F2" (= 46h, 32h) 8.2 CRC Check Sum Calculation Procedure (1) How to calculate the CRC