SMC Corporation of America
Elite Part Number Search
Search Results "CDBA2F50-300-HL-A54"

L Foot 3 300" F Rod lIanoe 1 pc. 5 cl Cemer Irvnnion "n ' DCS. n Bore size Suffix for cylinder Single Side f---iUc-+ ;:-:, ton , , ,pa, UI":c,:-J .. 125'" Auto switch 125 mm 140mm l60mm 1\10 I ,Nil.' I Wrthout auto S\VlICh I . 1'60 ~ Reier to the table below lor the applicable aulO switch model.

Indicator light Lead wire length (m) Note) Load voltage Wiring (Output) Special function Type Electrical entry Applicable load Connector Auto switch model 0.5 (Nil) 3 (L) 5 (Z) AC DC CJ1 100 V, 200 V A53 A54 PLC 24 V 2-wire 12 V Relay, PLC Reed switch Solid state switch Yes CJP 3-wire (Equiv.

Indicator light Lead wire length (m) Note) Load voltage Wiring (Output) Special function Type Electrical entry Applicable load Connector Auto switch model 0.5 (Nil) 3 (L) 5 (Z) AC DC CJ1 100 V, 200 V A53 A54 PLC 24 V 2-wire 12 V Relay, PLC Reed switch Solid state switch Yes CJP 3-wire (Equiv.

mm H: Lead wire length 600 mm M: With lead wire (length 300 mm) L: With lead wire (length 300 mm) Note) S type is not available with AC mode, since a rectifier prevents surge voltage generation.

400 Displacement (m) Displacement (m) 250 350 200 300 40 30 20 10 0 30 25 20 15 10 5 0 Load (N) Load (N) MSQXB30A MSQXB50A 350 300 300 250 Displacement (m) Displacement (m) 250 200 200 150 150 100 100 50 40 30 20 10 0 100 80 60 40 20 0 Load (N) Load (N) 336 MSQX Series Low-Speed Rotary Table Rack & Pinion Type Construction CRB2 CRB1 MSU CRJ CRA1 o i @5 @6 t y !

Magnet: D (Built-in), Series: BA2 (with End Lock), Mounting: F (Front Flange), Tube Material: Aluminum Tube, Bore Size: 50mm, Port Thread: Rc, Stroke: 350mm, Rod Boot: w/o Gaiter w/Cushion Both Sides, Cushion: Air Cushion, Lock Position: H (Rear Locking), Release Type: N (Non-locking Type), Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED

Magnet: D (Built-in), Series: BA2 (with End Lock), Mounting: F (Front Flange), Tube Material: Aluminum Tube, Bore Size: 50mm, Port Thread: Rc, Stroke: 175mm, Rod Boot: K (Heat Resistant Tarpaulin, Cushion: Both Sides), Cushion: Air Cushion, Lock Position: H (Rear Locking), Release Type: N (Non-locking Type), Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED

Magnet: Built-in, Series: with End Lock, Mounting: Front Flange, Tube Material: Aluminum Tube, Bore Size: 50mm, Port Thread: Rc, Stroke: 350mm, Rod Boot: w/o Gaiter w/Cushion Both Sides, Cushion: Air Cushion, Lock Position: Rear Locking, Release Type: Non-locking Type, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Series: with End Lock, Mounting: Front Flange, Tube Material: Aluminum Tube, Bore Size: 50mm, Port Thread: Rc, Stroke: 175mm, Rod Boot: Heat Resistant Tarpaulin, Cushion: Both Sides, Cushion: Air Cushion, Lock Position: Rear Locking, Release Type: Non-locking Type, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: -, Number: -

100 200 300 400 500 100 200 300 400 500 Piston speed (mm/s) Horizontal mounting Piston speed (mm/s) Vertical mounting Selection O.K. NO NO YES Is it possible for cable of stroke reading cylinder to be wired separately from the power line? Is there any influence of noise? YES NO YES NO Can the system be operated below 14.5 mT? Do not use it since it will result in a miscount.

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port

: 50, Stroke(mm): 130, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: A54

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 175, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 570, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 650, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port

Air cylinder series CA2 has been introduced with specifications and dimensions equivalent to the existing CA1 series. Several improvements have been made to the CA2 series including lateral load improvement, increase in cushioning capacity and adoption of?a new cushion seal. There has been enhanced efficiency in handling for cushion valve adjustment, and weight has been reduced by 5 to 15%

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CBA1 50MM DBL-ACT AUTO-SW, ACTUATOR, CBA1/CBA2 TIE-ROD CYL END LOCK, NE, CBA1 50MM DBL-ACT AUTO-SW, 7.93664 lb

Air cylinder series CA2 has been introduced with specifications and dimensions equivalent to the existing CA1 series. Several improvements have been made to the CA2 series including lateral load improvement, increase in cushioning capacity and adoption of?a new cushion seal. There has been enhanced efficiency in handling for cushion valve adjustment, and weight has been reduced by 5 to 15%

Magnet: D (Built-in), Series: BA2 (with End Lock), Mounting: F (Front Flange), Tube Material: Aluminum Tube, Bore Size: 50mm, Port Thread: Rc, Stroke: 500mm, Rod Boot: w/o Gaiter w/Cushion Both Sides, Cushion: Air Cushion, Lock Position: H (Rear Locking), Release Type: L (Locking), Auto Switch: J59W--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewired Connector: L (3m)