Magnet: Built-in, Mounting: Both Ends Tapped, Type: Air-hydro, Bore Size: 20mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 10mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: -, Number: -, Mounting
Magnet: Built-in Magnet, Bore Size: 6 mm, Port Thread: Bore 6~25:M5, Bore 32: Rc 1/8, Stroke: 10 mm, Auto Switch: A90--Reed, AC Volt, Horizontal, 0.5M, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in Magnet, Bore Size: 16 mm, Port Thread: Bore 6~25:M5, Bore 32: Rc 1/8, Stroke: 10 mm, Auto Switch: A90--Reed, AC Volt, Horizontal, 0.5M, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in Magnet, Bore Size: 25 mm, Port Thread: Bore 6~25:M5, Bore 32: Rc 1/8, Stroke: 10 mm, Auto Switch: A90--Reed, AC Volt, Horizontal, 0.5M, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in Magnet, Bore Size: 10, Port Thread: Bore: 6, 10, 16, 20, 25, M5x0.8 ; Bore: ø32, Rc1/8, Stroke: 10mm, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in Magnet, Bore Size: 16, Port Thread: Bore: 6, 10, 16, 20, 25, M5x0.8 ; Bore: ø32, Rc1/8, Stroke: 10mm, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in Magnet, Bore Size: 6, Port Thread: Bore: 6, 10, 16, 20, 25, M5x0.8 ; Bore: ø32, Rc1/8, Stroke: 10mm, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Mounting: Through Hole, Both Ends Tapped, Bore Size: 12mm, Stroke: 10mm, Option: Standard (Rod End Female Thread), Auto Switch: A90--Reed, AC Volt, Horizontal, 0.5m, Lead Wire or Prewired Connector: -, Number: -, Thread: -
Magnet: Built-in, Mounting: Through Hole, Both Ends Tapped, Bore Size: 16mm, Stroke: 10mm, Option: Standard (Rod End Female Thread), Auto Switch: A90--Reed, AC Volt, Horizontal, 0.5m, Lead Wire or Prewired Connector: -, Number: -, Thread: -
Magnet: Built-in, Mounting: Through Hole, Both Ends Tapped, Bore Size: 20mm, Stroke: 10mm, Option: Standard (Rod End Female Thread), Auto Switch: A90--Reed, AC Volt, Horizontal, 0.5m, Lead Wire or Prewired Connector: -, Number: -, Thread: -
Magnet: Built-in Magnet, Bore Size: 25, Port Thread: Bore: 6, 10, 16, 20, 25, M5x0.8 ; Bore: ø32, Rc1/8, Stroke: 10mm, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in Magnet, VAC Side Tube/Rod End Shape: Cap Piping/Male Thread, Bore Size: 16mm, Port Thread: M5x0.8 (Bore 10, 16, 20, 25), Rc1/8 (Bore 32), Stroke: 10mm, Auto Switch: A90--Reed, AC Volt, Horizontal, 0.5m, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Mounting: Through Hole, Both Ends Tapped, Bore Size: 20mm, Stroke: 10mm, Option: Standard(Rod End Female Thread), Auto Switch: A90--Reed, AC Volt, Horizontal, 0.5M, Lead Wire or Prewired Connector: -, Number: -, Thread: -
This is a legacy product, and replaced byCJP2D16-10D
Test range Thermometer Test equipment Pressure tap Pressure tap Throttle valve on the upstream side Flow meter Throttle valve on the downstream side 2d 6d 20d 10d Fig. (3) Test circuit based on IEC60534-2-3, JIS B 2005 12 VXB Series Flow Rate Characteristics Note) Use this graph as a guide. If an accurate flow rate is required, refer to pages 8 to 12.
Test range Thermometer Equipment Pressure Pressure for test tap tap Restrictor Flow Restrictor on the 2d 6d on the meter downstream side upstream side r 20d r 10d Fig. (3) Test circuit based on IEC60534-2-3, JIS B 2005 32 Series VXN Flow-rate Characteristics Note) Use this graph as a guide. In the case of obtaining an accurate flow rate, refer to pages 28 through to 32.
An auto switch for detecting the location can be mounted. 10D MHZ2-16D 20D 10DN MHZ2-16DN 20DN Tool stand Added to the standard tool adapter The height for setting a tool can be adjusted. An auto switch for detecting a tool can be mounted. (Series MA3 only) (Series MA3 only) Rotary actuated type MHR2-10 15 Refer to AHC system Series MA. 12-12-17
Please contact us for the latest version.sales@ocaire.com, GRIPPER PARALLEL TYPE, ACTUATOR, MHZ2 GRIPPER, PARALLEL, EE, 10MM MHZ2 DBL-ACT AUTO-SW, .26393 lb, ActionModelBore size (mm)Gripping force Note 1)Opening/ Closing stroke (Both sides) (mm)Note 2) Mass (g) Gripping force per finger Effective value (N) ExternalInternalDouble actingDouble actingMHZ2-10D(N)101117455
Please contact us for the latest version.sales@ocaire.com, GRIPPER PARALLEL TYPE, ACTUATOR, MHZ2 GRIPPER, PARALLEL, EE, 10MM MHZ2 DBL-ACT AUTO-SW, .28676 lb, ActionModelBore size (mm)Gripping force Note 1)Opening/ Closing stroke (Both sides) (mm)Note 2) Mass (g) Gripping force per finger Effective value (N) ExternalInternalDouble actingDouble actingMHZ2-10D(N)101117455
Please contact us for the latest version.sales@ocaire.com, GRIPPER PARALLEL TYPE, ACTUATOR, MHZ2 GRIPPER, PARALLEL, EE, 10MM MHZ2 DBL-ACT AUTO-SW, .38968 lb, ActionModelBore size (mm)Gripping force Note 1)Opening/ Closing stroke (Both sides) (mm)Note 2) Mass (g) Gripping force per finger Effective value (N) ExternalInternalDouble actingDouble actingMHZ2-10D(N)101117455