Cylinder (Tube) Inner Diameter(φ): 140, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 140, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 140, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 140, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 140, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 140, Stroke(mm): 700, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 140, Stroke(mm): 990, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Magnet: Built-in, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 140mm, Thread: NPT, Stroke: 200mm, Option: -, Cylinder Switch Type: -, Lead Wire or Pre-wired Connector: -, Number: -, Lock Unit Built-in Magnet: -, Lock Unit Switch Type: -
Magnet: Built-in, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 140mm, Thread: NPT, Stroke: 150mm, Option: w/o Cushion, Cylinder Switch Type: -, Lead Wire or Pre-wired Connector: -, Number: -, Lock Unit Built-in Magnet: -, Lock Unit Switch Type: -
Magnet: Built-in, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 140mm, Thread: NPT, Stroke: 300mm, Option: -, Cylinder Switch Type: -, Lead Wire or Pre-wired Connector: -, Number: -, Lock Unit Built-in Magnet: -, Lock Unit Switch Type: -
to 6000 7 R/W dtL1 (Delay time at OFF) S16 0 Y Setting of OUT1 delay time at OFF 10 ms increment -83No.PF-OMZ0002-A Product individual parameters (continued) Data Data Index Sub Access Initial value type storage 1 Parameter Set value 4 Remarks index dec hex 2 3 AC1_L (Mantissa L) U16 0 Y Setting range 0 to 9 Setting of OUT1 mantissa Unit: when L is selected OUT1 accumulated flow 1 R/W 1300
range 0 to 6000 7 R/W dtL1 (Delay time at OFF) S16 0 Y Setting of OUT1 delay time at OFF 10 ms increment -79No.PF-OMY0002 Product individual parameters (continued) Data Data Index Sub Access Initial value type storage 1 Parameter Set value Remarks index dec hex 2 3 AC1_L (Mantissa L) U16 0 Y Setting range 0 to 9 Setting of OUT1 mantissa Unit: when L is selected OUT1 accumulated flow 1 R/W 1300
Window comparator hysteresis) Setting of OUT2 hysteresis (Window comparator) 5 R/W U16 400 Y Settable values 0x0 to 0x1770 (0 to 6000) 6 R/W dt2 (Delay time) U16 0 Y Setting of OUT2 delay time 10 ms increment Setting of OUT1 set value Unit specification (Unit): When "L" is selected Setting range 0x0 to 0x270F (0 to 9) AC1_L (OUT1 set value (L)) S16 0 Y OUT1 accumulated flow setting 1 R/W 1300
Window comparator hysteresis) Setting of OUT2 hysteresis (Window comparator) 5 R/W U16 400 Y Settable values 0x0 to 0x1770 (0 to 6000) 6 R/W dt2 (Delay time) U16 0 Y Setting of OUT2 delay time 10 ms increment Setting of OUT1 set value Unit specification (Unit): When "L" is selected Setting range 0x0 to 0x270F (0 to 9) AC1_L (OUT1 set value (L)) S16 0 Y OUT1 accumulated flow setting 1 R/W 1300
83No.PF-OMY0005-A Product individual parameters (continued) Data Data Index Sub Access Initial value Set value 4 Remarks type storage 1 Parameter index 2 3 dec hex AC_1ot (Selection of output type) U8 0 Y 0: 1_P (Normal output) 1: 1_n (Reverse output) 1290 0x050A 0 R/W OUT1 setting (AC) P1(n1)_L (Selection of output set value) U32 0 Y 0 to 999,999,999 Common for all ranges, units, and criterion 1300
) Setting of OUT1 delay time at ON. 0x0 ~ 0x1770 (0 ~ 6000) 0.01 s increment dtH1 (OUT1 delay time at ON) Y U16 0x0 6 R/W (0) dtL1 (OUT1 delay time at OFF) Setting of OUT1 delay time at OFF. 0x0 ~ 0x1770 (0 ~ 6000) 0.01 s increment Y U16 0x0 7 R/W (0) OUT1 Accumulated threshold value setting (L) Consider the accumulated inclination when reading or writing the accumulated value. 0x0514 (1300
(Page 84) SAVE (Accumulated flow value hold setting) 0: oFF (Not held) 1: 2.0 min 2: 5.0 min 1300 0x0514 0 R/W U8 0 Y 1800 0x0708 0 R/W diSP (Display OFF setting) U8 0 Y 0: on 1: oFF Pin (Security code Used/Not used) Security code U8 0 Y 0 :unused 1: use 1810 0x0712 0 R/W PinCode (Security code setting) Setting range 0x0 to 0x03E7 (0 to 999) 1811 0x0713 0 R/W U16 0 Y Line name 1st letter
(Page 86) SAVE (Accumulated flow value hold setting) 0: oFF (Not held) 1: 2.0 min 2: 5.0 min 1300 0x0514 0 R/W U8 0 Y 1800 0x0708 0 R/W dSP (Display OFF setting) U8 0 Y 0: on 1: oFF Pin (Security code Used/Not used) Security code U8 0 Y 0 :unused 1: use 1810 0x0712 0 R/W PinCode (Security code setting) Setting range 0x0 to 0x03E7 (0 to 999) 1811 0x0713 0 R/W U16 0 Y Line name 1st letter U8
Length (mm) Peak pressure (compared with existing product) 8 2000 2 times 10 1300 2.5 times 13 800 3 times In SMC test conditions. Refer to page 5 for the relation between the upstream piping and peak pressure. Oscillation may occur when supply air is insufficient. Upstream piping I.D. Must be larger than 8. Be careful that pressure drop does not occur. 2 4.
Pressure 0.15MPa Range MAX.Inlet Air Pressure 1.0MPa Ambient Temperature 2 ~ 40oC(Relative Humidity of 85% or less) Power source 1 AC230V10% 50Hz (Note 4) Specification Operating current(Note 2) 1.2A 1.2A 1.2A 1.4A 2.7A 2.9A Electrical Power consumption(Note 2) 180W 180W 180W 208W 385W 420W Circuit Breaker (Note 3) 5A 10A Noize at 50Hz 50dB Condenser Air cooling Refrigerant R134aHFC(WGP:1300