Solid state auto switch Connector IC circuit 3-wire (NPN) 2-wire 5 V, 12 V 12 V Terminal conduit Relay PLC Yes 24 V 3-wire (NPN) Diagnostic indication (2-color indicator) IC circuit 5 V, 12 V 12 V 3-wire (PNP) 2-wire Grommet 3-wire (NPN) IC circuit Water resistant (2-color indicator) 5 V, 12 V M9PAV1 M9PA1 3-wire (PNP) 2-wire M9BAV1 M9BA1 12 V 5 V, 12 V 5 V H7NF A96 A93 A90 B54 B64 C73C
MY1CW16/20 MY1MW16/20 MX B A MTS Reed Switch Solid State Switch D-A90(V), D-A93(V), D-A96(V) (mm) D-M9N(V), D-M9P(V), D-M9B(V) D-F9NW(V), D-F9PW(V), D-F9BW(V) MY 16 20 Mounting position 16 20 Mounting position Mounting position 16 20 93 94 A A A 73 74 70 90 CY 107 106 B B B 87 86 90 110 6.5 7 8.5 6.5 Operating range Note) Operating range Note) Operating range Note) 11 7.5 MG CX MY1MW25/32
, D-A93 (V), D-A96 (V) Switch operation range Stroke (mm) Model 25 50 75 100 125 150 175 200 225 250 275 300 A 52.5 31.5 27.5 27.5 27.5 27.5 B 79.5 100.5 125.5 150.5 175.5 200.5 B A MXW 8 6 W 32.5 11.5 7.5 7.5 7.5 7.5 V 99.5 120.5 145.5 170.5 195.5 220.5 A 51 31 31 31 31 B 104 124 149 174 199 MXW12 6 W 31 11 11 11 11 V 124 144 169 194 219 W V A 59.5 34.5 34.5 34.5 34.5 34.5 B 135.5
F9PWV F9BWV Solid state switches marked with are produced upon receipt of order. 200 V A93 M9N M9P M9B F9NW F9PW F9BW F9BA A72 A73 A73C A79W F7NV F7PV F7BV J79C F7NWV F7BWV F7BAV A72H A73H F79 F7P J79 F79W F7PW J79W F7BA F79F P5DW Grommet Yes 100 V 12 V Relay, PLC 2-wire 24 V 12 V Connector Diagnostic indication (2-color indication) Grommet 3-wire (NPN) 5 V, 12
MY1CW16/20 MY1MW16/20 B A Reed Switch Solid State Switch D-A90(V), D-A93(V), D-A96(V) (mm) D-M9N(V), D-M9P(V), D-M9B(V) D-F9NW(V), D-F9PW(V), D-F9BW(V) 16 20 Mounting position Mounting position 16 20 A A B B Operating range Note) Operating range Note) Solid State Switch Reed Switch 24 Series MY1W Mounting of Auto Switch & Installation of Lead Wire Cover (50, 63) Caution Be sure to install
= 200 mm/s Supply pressure: P = 0.5 MPa Load mass: M = 0.2 kg (2N) Cylinder stroke: 300 mm Load mass: M = 10 kg Cylinder stroke: 400 mm Actuating orientation: Vertical transfer of work (Rod side flange) Maximum speed: v = 300 mm/s Supply pressure: P = 0.5 MPa REC25 provisionally selected from graph (1) (M = 10 kg, v = 300 mm/s) REC20 provisionally selected from graph (1) (M = 0.2 kg, v =
= 200 mm/s Supply pressure: P = 0.5 MPa Load mass: M = 0.2 kg (2N) Cylinder stroke: 300 mm Load mass: M = 10 kg Cylinder stroke: 400 mm Actuating orientation: Vertical transfer of work (Rod side flange) Maximum speed: v = 300 mm/s Supply pressure: P = 0.5 MPa REC25 provisionally selected from graph (1) (M = 10 kg, v = 300 mm/s) REC20 provisionally selected from graph (1) (M = 0.2 kg, v =
Y7BW Y7BWV 2-wire 12 V Table Unit/Applicable Auto Switch Auto switch model Lead wire length (m) 0.5 (Nil) Load voltage Indicator light Applicable load Special functions Type Electrical entry Wiring (Output) Electrical entry direction In-line 3 (L) AC DC A90 A93 A96 M9N M9P M9B F9NW F9PW F9BW No 12 V 5 V,12 V Relay PLC IC circuit 100 V or less Reed switch Solid state switch 24 V 2-wire
B Reverse the mounting direction A Reed switch D-A90(V), D-A93(V), D-A96(A) mm Auto switch mounting Switch operating range Stroke (mm) 20 45 25 51 31 Type 25 50.5 30.5 30 59 39 10 35 15 40.5 20.5 Caution A B A B A B MXP10 Tool for auto switch mounting MXP12 5 Use the screwdriver with grip diameter 5 to 6 mm when set screw (attached to auto switch) is set.
12 V CY1H 12 V Solid state auto switch Reed auto switch Yes IC circuit CY1F CY1F 5 V, 12 V Relay, PLC Diagnostic indication (2-color indicator) Grommet 24 V 12 V CYP IC circuit 5 V, 12 V Water resistant (2-color indicator) M9PAV1 M9PA1 M9BAV1 M9BA1 12 V IC circuit 3-wire (NPN equivalent) A96V A96 5 V 12 V Yes 24 V Grommet Relay, PLC A93V2 A93 A90 100 V 2-wire A90V IC circuit No
Load voltage Indicator light Lead wire length (m) AC DC Auto switch model Applicable load Pre-wire connector Special function Type Electrical entry Wiring (Output) 5(Z) 0.5(Nil) 3(L) Perpendicular In-line Reed switch Solid state switch IC circuit 3-wire (NPN equivalent) A96 A96 5 V Grommet Yes Relay, PLC 2-wire A93V A93 100 V 24 V 12 V M9NV M9N 3-wire (NPN) IC circuit 5 V, 12 V M9PV
Lead wire length (m) Load voltage Auto switch model Electrical entry direction Special function Electrical entry Indicator light Wiring (Output) 0.5 (Nil) 3 (L) Applicable load Type AC DC 12 V In-line 24 V 100 V 12 V 2-wire Reed auto switch Grommet Yes Relay, PLC A93 3-wire (NPN) M9N 24 V Solid state auto switch Grommet Yes Relay, PLC 12 V 2-wire M9B Lead wire length symbols
Lead wire length (m) Auto switch model Electrical entry direction Load voltage Wiring (Output) Special function Electrical entry Indicator light Type 0.5 (Nil) 3 (L) Applicable load AC DC 12 V In-line A93 Reed auto switch 2-wire Grommet Yes 24 V 100 V Relay, PLC M9N 3-wire (NPN) 12 V Solid state auto switch Grommet Yes 24 V Relay, PLC M9B 2-wire 12 V Lead wire length symbols 0.5 mNil
Lead wire length (m) Load voltage Auto switch model Electrical entry direction Wiring (Output) Special function Electrical entry Indicator light Style 0.5 (Nil) 3 (L) Applicable load AC DC 12V Horizontal 100V 24V Reed switch 2-wire Relay, PLC Grommet Yes A93 12V 3-wire (NPN) M9N 24V Solid state switch Relay, PLC Grommet Yes 12V 2-wire M9B Lead wire symbol 0.5mNil (Example) A93
Type Load voltage Wiring (Output) 3 (L) 1 (M) 0.5 (Nil) Auto switch model Band mounting DC AC Applicable load Lead wire length (m) Indicator light Electrical entry 5 (Z) M9B M9BW 5 V 12 V 24 V 2-wire Yes Grommet Solid state auto switch Relay, PLC A93 100 V Yes 12 V 24 V 2-wire Grommet Reed auto switch Note 1) Lead wire length symbols: 0.5 mNil M9BW 1 m M M9BWM 3 m L M9BWL 5 m Z M9BWZ
Provided IC circuit Lead wire D-A90(V) and D-A93(V): Oil proof vinyl cabtire cord 2.7 0.18mm22-core (brown, blue) 0.5m D-A96(V): Oil proof vinyl cabtire cord 2.7 0.15mm23-core (brown, black, blue) 0.5m Isolation resistance 50M or more at DC500VM (between lead wire and case) Withstand voltage AC1500V for 1 minute (between lead wire and case) Operating time 1.2ms Ambient temperature
Note 7) Mounting position: AF+T+AR V V V V V + Attachment Nt Nil Without attachment V V V V V V Mounting position: AF+AR+V V V V V V1 Note 8) Mounting position: V+AF+AR V V V V + d Pressure relief 3 port valve e Set pressure Note 9) Nil 0.05 to 0.7 MPa setting V V V V V 1 0.02 to 0.2 MPa setting V V V V V + Nil Polycarbonate bowl V V V V V 2 Metal bowl V V V V V 6 Nylon bowl V V V V V 8
-color indication) 2-wire 12 V M9BA** v v V v v G5BA** V v v With diagnostic output (2-color indication) 4-wire (NPN) 5 V, 12 V F59F G59F V V v v IC circuit Magnetic field resistant (2-color indication) 2-wire (Non-polar) P3DWA V V v Yes 3-wire (NPN equivalent) 5 V A96 V V IC circuit 100 V A93 V V Reed auto switch No 100 V or less A90 V V IC circuit Yes 100 V, 200 V A54