+ 100 (n 2) 35 + 30 (n 2) 10 35 100 Note) For cylinders with two D-A93/M9/M9W auto switches.
Air Cylinder: Standard Type Double Acting, Single Rod Series NCG/CG1 20, 25, 32, 40, 50, 63, 80, 100 How to Order Without auto switch 00 04 L 25 N NCG 00 N 25 M9NW L 04 NCDG With auto switch Number of auto switches Built-in magnet Nil S n 2 pcs. 1 pc. n pcs.
m t L d m t D d9 D d9 l l Part no.
D-M9V, D-M9WV D-M9A D-M9AV A B W A B W A B W A B W 12 6.2 6.2 3.8 6.2 6.2 1.8 6.2 6.2 5.8 6.2 6.2 3.8 16 6.7 6.7 3.3 6.7 6.7 1.3 6.7 6.7 5.3 6.7 6.7 3.3 20 7.5 10 7.5 10 7.5 10 2 7.5 10 25 8 12 8 12 8 12 8 12 Auto Switch Mounting Height U [mm] Auto switch model Bore size D-M9V, D-M9WV, D-M9AV U 12 19.5 16 21 20 23 25 24.5 W A B A Operating Range [mm] Auto switch model Applicable
C (mm) Proper mounting position Proper mounting position Proper mounting position D-M9 D-M9W D-M9V D-M9WV D-M9 D-M9W D-M9V D-M9WV D-M9 D-M9W D-M9V D-M9WV Model Model Model A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E A B C D E 16.5 25 4.5 18.5 49 6.5 7.5 38 21 MIW8-8D MIS12
Compact Cylinder: Standard Double Acting, Single Rod Series CQ2 12, 16, 20, 25, 32, 40, 50, 63, 80, 100 How to Order Without auto switch 30 20 CQ2 B D 12 to 25 Without auto switch CQ2 B 32 30 Z D 32 to 100 30 32 Z M9BW B CDQ2 D With auto switch Auto switch With auto switch (Built-in magnet) Nil Without auto switch Mounting Refer to the below table for applicable auto switches.
D-P4DWL is compatible with 40 to 100. D-P4DW is assembled at the time of shipment. Lead wire length symbols: 0.5 m Nil 1 m M 3 m L 5 m Z None N (Example) M9NW (Example) M9NWM (Example) M9NWL (Example) M9NWZ (Example) J79CN Since there are other applicable auto switches than listed, refer to page 837 for details.
Consult with SMC regarding water resistant types with the above model numbers. * Solid state auto switches marked with are produced upon receipt of order. ** Since D-A9and D-A9V cannot be mounted on 50, use of D-Z7 or D-Z80 is recommended. * Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ D* Since there are other applicable
(Make sure that there is no rotation backlash in the table.) 3 Tighten both adjustment bolts c and d to approx. 45. Note 1) Tighten both adjustment bolts c and d to approx. 45. Note 1) 4 Lock adjustment bolts c and d with fixing nuts. Note 2) Lock adjustment bolts c and d with fixing nuts.
Air Cylinder Standard: Double Acting, Single Rod 40, 50, 63, 80, 100 Series CA2 RoHS How to Order L 50 100 CA2 Z D 50 100 M9BW N W Z With auto switch CDA2 Made to Order For details, refer to the next page.
Air Cylinder Short Type Standard: Double Acting, Single Rod CG3 Series 20, 25, 32, 40, 50, 63, 80, 100 RoHS CJ1 How to Order CJP CJ2 L 25 CG3 100 N JCM CDG3 L 100 M9BW N 25 C With auto switch CM2 With auto switch (Built-in magnet) CM3 Made to Order For details, refer to page 366.
Cylinder with Lock Double Acting, Single Rod 32, 40, 50, 63, 80, 100 MWB Series RoHS How to Order 50 B 40 MWB With auto switch MDWB M9BW B 40 50 Bore size With auto switch (Built-in magnet) Number of auto switches Pivot bracket Auto switch 32 32 mm 40 40 mm 50 50 mm 63 63 mm 80 80 mm 100 100 mm Nil 2 S 1 3 3 n n Only for D and T mounting types.
B Basic L Axial foot F Rod ange G Head ange C Single clevis D Double clevis T Center trunnion * Trunnion type is mounted before shipment. * Other mounting brackets 32 to 100: Shipped together. 125: Assembled before shipment. * For applicable auto switches, refer to the table below. * Only for D and T mounting types. * Pivot bracket is shipped together with the product. * For details, refer
ISO Standard Hydraulic Cylinder 40, 50, 63, 80, 100 CHSD Series 10 MPa CHQ How to Order CHK 100 M9BW CH D SD B 40 CHN Magnet for auto switch Number of auto switches Series type CHM Nil D Without Nil S n 2 pcs. Built-in Symbol D Nominal pressure CHS CHS 1 pc. 10 MPa "n" pcs.
Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.
Protrusion of Auto switch Lead wire type In-line entry Perpendicular entry Illustration Auto switch Hysteresis L L Auto switch operating position (ON) Finger position Auto switch operating position (OFF) D-M9 D-M9W D-M9V D-M9WV Model Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close Hysteresis 6.5 6.5 6.5 6.5
D-M9V D-M9W D-M9WV D-M9A D-M9AV D-A9 D-A9V U B O S A Proper Auto Switch Mounting Position (mm) Auto Switch Mounting Height (mm) D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV Auto switch model Auto switch model D-A9 D-A9V D-M9V D-A9V A B U U A B Bore size Bore size 32 40 50 63 32 40 50 63 12 8 30 9 5 27.5 16 12 32 11.5 7.5 30 14 10 37.5 14.5 10.5 35 16.5 12.5 42.5 17.5 13.5 40.5 Note) The actual mounting
Cylinder with Lock Double Acting, Single Rod 125, 140, 160, 180, 200, 250 Series CLS How to Order CLS L D 125 100 M9B M9B With Auto Switch CDLS M9BW L D 125 100 With auto switch (Built-in magnet) Cylinder unit auto switch Port thread type Nil TN TF Lock unit auto switch Nil Without auto switch Mounting style B L F G Rc NPT G Nil Without auto switch Select applicable auto switches from the