Controller (VYU5-D) External appearance of exclusive controller RUN1 STOP START SEL. SW RESET RUN2 RUN1 OV INPUT 6 7 5 8 4 + 9 3 SET UP A 2 B 1 0 C D 1 E F 0 to 10V V R 1 OUTPUT SET UP BALANCE CONTROLLER VYU5-D 2 V R 2 OV ERR.
C F G D E F G D T F G D F F G E S F G E L F G E T F G G S F G G L Fluid name Applicable element type, material Nominal filtration accuracy (m) Fiber element Polypropylene 10 Industrial water Fiber element Polypropylene 20 Water for cleaning Fiber element Polypropylene 20 Water Fiber element Cotton 10 Fragrances Micromesh element Stainless steel 316 10 Hot water Micromesh element Stainless
H C37 3/4 20 J Stainless steel D 200 VAC E 230 VAC 6 25A N.C.
Press the "UP"and "DOWN"buttons to change the set value. d. Press the "SET"button. d. Press the "SET"button. The set value will light up. The set value will light up. * When the set value is flashing, it is not registered. * When the set value is flashing, it is not registered.
C D Can be mounted 2 ways Improves ease of mounting the unit. A B Table running accuracy (mm) The LG1 series provides a stainless steel frame (LG1TH) for customers who required rigidity with an extendable aluminum frame. Refer to page 41 for further details.
equipped as standard.) sPage 177 sPage 180 With fluid fill port 156 A Thermo-chiller Inverter Type HRSH Series Circulating Fluid Temperature Controller Circuit diagram HRSHl-W-l (Water-cooled refrigeration) HRSHl-A-l (Air-cooled refrigeration) HRS Ventilation DC inverter fan HRS 090 Water regulating valve Air release valve for facility water discharge HRS 100/150 WPR Facility water outlet D
Select the model with air flow capacity exceeding the calculated corrected air flow from data D of the table below.
Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-15 Connection of RS-232C HRSH Series 3.3 Installation 3-27 HRX-OM-Q026 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly.
The signal has to be converted by a A/D converter for pressure display or switch output. Current Output signal is a current signal in the range of 4 to 20[mA]. The signal is transformed into a voltage signal before being converted by a A/D converter for pressure display or switch output.
AK Applicable tubing O.D. d L2 L3 M Inch size ASS ASR D2 L1 ASF T2 L4 H1 H1 (Hexagon width across flats) (Hexagon width across flats) H2 H2 (He (Hexagon width across flats) xagon width across flats) (Hexagon width across flats) D3 A1 L5 D1 A2 T1 Inch Size L4 Weight (g) d T1 D1 A2 A1 D3 M L3 L2 L1 H1 H2 D2 Max. Min.
fluid Dry air, N2 3-color/ 2-screen display Accumulated value 2-row display of main screen and sub screen Peak/Bottom value Instantaneous flow rate (Main screen) Set value (Sub screen) Line name Expanded flow range Compact, Space saving Wide range of flow measurement with one product Compared with the current PF2A, Flow ratio 78 % reduction Weight 74% reduction 100:1 Mounting space 1100
Use flexible tubing in between to avoid such an effect. 1100
Use flexible tubing in between to avoid such an effect. 1100
Changing PD04 from 00212100 to 0021210D 0 D 41 - (2) Symbol allocation using the setup software: Changing pins CN1-16 to Gain changing selection (CDP). Change PD04 from 00212100 to 0021210D in the I/O tab. Select Single Axis Write. Cycle the power the parametersto be enabled.
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 700, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 700, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No