position 9.5 4 Most sensitive position 6 842 C 2-Color Indicator Solid State Auto Switch Direct Mounting Type D-M9NW(V)/D-M9PW(V)/D-M9BW(V) RoHS Refer to SMC website for the details of the products conforming to the international standards.
(Red Green Red) D-M9NWV D-M9NW D-M9BW D-M9BWV D-M9PWV D-M9PW Auto switch model In-line Perpendicular In-line Perpendicular In-line Perpendicular Electrical entry direction 3-wire 2-wire Wiring type NPN PNP Output type 24 VDC relay, PLC IC circuit, Relay, PLC Applicable load 5, 12, 24 VDC (4.5 to 28 V) Power supply voltage 10 mA or less Current consumption 24 VDC (10 to 28 VDC) Load voltage
Style D-M9NW(V)/D-M9PW(V)/D-M9BW(V) RoHS Refer to SMC website for the details of the products conforming to the international standards.
Weight (g) D-M9NW(V) D-M9PW(V) D-M9BW(V) Auto switch model Auto Switch Internal Circuit 8 8 7 0.5 D-M9NW(V) 14 14 13 1 Lead wire length (m) 41 41 38 3 DC (+) Brown 68 68 63 5 Main circuit of switch Main circuit of switch Main circuit of switch OUT Black (mm) Dimensions D-M9W M2.5 x 4 l DC () Blue Slotted set screw Indicator light D-M9PW(V) 2.6 DC (+) Brown 2.7 2.8 4 22 OUT Black 3.2 DC ()
Auto Switch Proper Mounting Height (Standard type) [mm] Auto switch model D-F5l D-J59 D-F59F D-F5lW D-J59W D-F5BA D-F5NT D-Y59l D-Y7P D-Y7lW D-Y7BA D-Z7l D-Z80 D-M9l D-M9lW D-M9lA D-A9l D-A9lV D-M9lV D-M9lWV D-M9lAV D-A5l D-A6l D-A59W D-Y69l D-Y7PV D-Y7lWV D-P3DWA D-P4DW D-G39 D-K39 D-A3l D-A44 Bore size Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht 32 24.5 23 27.5 23
For details, refer to pages 443 and 445. 273
CHKD Series How to Mount and Move the Auto Switch
Mounting example for D-M9(V), M9W(V), M9A(V). 341
CHSD Series How to Mount and Move the Auto Switch
Reed auto switch: D-A9, D-A9V Solid state auto switch: D-M9(A), D-M9W D-M9 Compact auto switch D-A9 5 Air Slide Table MXQ Series Functional Options ' With buffer mechanism Protects workpieces and tools by eliminating impact at the extension stroke end Buffer unit is auto switch capable.
(Red Green Red) D-M9NWV D-M9NW D-M9BW D-M9BWV D-M9PWV D-M9PW Auto switch model In-line Perpendicular In-line Perpendicular In-line Perpendicular Electrical entry direction 3-wire 2-wire Wiring type NPN PNP Output type 24 VDC relay, PLC IC circuit, Relay, PLC Applicable load 5, 12, 24 VDC (4.5 to 28 V) Power supply voltage 10 mA or less Current consumption 24 VDC (10 to 28 VDC) Load voltage
position 143 2-Color Indicator Solid State Auto Switch Direct Mounting Type D-M9NW(V)/D-M9PW(V)/D-M9BW(V) RoHS Refer to SMC website for the details of the products conforming to the international standards.
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
Magnet: Built-in, Mounting: Front Flange, Type: Standard, Bore Size: 63mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 75mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Auto Switch Mounting Grooves, Mounting Bolt: -, Rod End Bracket: -, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector:
How to Mount and Move the Auto Switch Auto switch mounting screw M2.5 x 0.45 x 4 L Watchmakers (precision) screwdriver
If this is not done, the tie-rods or piston rod assembly will be damaged. 75
Series C96 How to Mount and Move the Auto Switch 1 Tie-rod Mounting Type Mounting Bracket
For details, refer to page 443. 413
CHA Series How to Mount and Move the Auto Switch
BQ-1 BQ-2 BQ2-012 Weight (g) 1.5 1.5 5 259
CHQB/CHQWB Series How to Mount and Move the Auto Switch
Single round shaft: ClRA1BT Double shaft (round shaft, with four chamfers): ClRA1BJ Double round shaft: ClRA1BK D D D H H H H UU UU M N 0 0.2 G D L 0 0.2 [mm] [mm] [mm] Size D (g6) H Size D (g6) G H M N UU L Size D (g6) H UU 30 8 25 50 15 36 63 17 41 80 20 50 100 25 60 30 8 6 25 10 8 75 7.8 50 15 11 36 20 15 118 14 63 17 13 41 22 17 139 16 80 20 15 50 25 20 167 19 100 25 19 60 30 25 202 24
LAT LEJS40 LEJS63 Applicable auto switches D-M9N(V)-900, D-M9P(V)-900, D-M9B(V)-900 D-M9NW(V)-900, D-M9PW(V)-900, D-M9BW(V)-900 LZ *4 Please consult with SMC for non-standard strokes as they are produced as special orders. LC3F2 * Specifications and dimensions for the 25A-series are the same as standard products.
M9B D-M9B M9N D-M9N Solid state switch M9P D-M9P M9BW D-M9BW Solid state switch (2-color indication) M9NW D-M9NW M9PW D-M9PW *Note 1) lead wire length symbols 0.5mNil. (Case) M9NW 1mM (Case) M9NWM 3mL (Case) M9NWL 5mZ (Case) M9NWZ *Note 2) When 2 auto-switches are specified they are assembled for shipping.
M9B D-M9B M9N D-M9N Solid state switch M9P D-M9P M9BW D-M9BW Solid state switch (2-color indication) M9NW D-M9NW M9PW D-M9PW *Note 1) lead wire length symbols 0.5mNil. (Case) M9NW 1mM (Case) M9NWM 3mL (Case) M9NWL 5mZ (Case) M9NWZ *Note 2) This product can be mounted on the NEXTAGE KAWADA ROBOTICS CORPORATION. 3-2.