SMC Corporation of America
Elite Part Number Search
Search Results "CDRQ2BW10-90-A93"

Applicable load IC circuit, Relay, PLC Load voltage 24V or less 48V or less 100V or less AC DC AC DC AC DC Maximum load current 50mA 40mA 20mA Contact protection circuit None Internal resistance D-A93, D-A93V, D-A96, D-A96V (with indicator light) 1 or less (including 3m lead wire length) D-A93, D-A93V D-A96, D-A96V Auto switch part no.

90 38 4.5 9 16.5 21.5 M10 x 1 87 18.5 13.5 32 111 23 CY1SG25-Z RJ1412LN 40 1.5 73 M6 x 1 Rc1/8 NPT1/8 G1/8 70 99 90 42 4.5 9 16.5 21.5 M14 x 1.5 96 18.5 13.5 32 111 44 -X CY1SG32-Z RJ2015HN M8 x 1.25 Rc1/8 NPT1/8 G1/8 40 75 119 110 50 3 5.5 11 91 18.5 24.5 M20 x 1.5 116 18.5 12.5 31 134 46 CY1SG40-Z RJ2015LN M8 x 1.25 Rc1/4 NPT1/4 G1/4 65 105 142 120 64 2 4.5 9 99 20.5 26.5 M20 x 1.5 139

Push down the lever 90 degrees to pull out the shock absorber. 6-2. Fix the shock absorber with a set screw. Set screw tightening torque: 1.5 Nm Lever Caution After replacing the shock absorber, tighten the set screw firmly and apply grease to the shock absorber rod end surface (Fig.7).

Mounting bolt M5 X 75l M5 X 85l M5 X 80l M5 X 90l M5 X 90l M5 X 100l M5 X 80l M5 X 90l M6 X 105l M6 X 135l M8 X 105l M8 X 135l D 75 85 80 90 90 100 80 90 105 135 105 135 Part No.

Mounting bolt C D Mounting bolt Mounting bolt D 65 70 75 85 95 120 145 85 95 105 130 155 90 100 110 135 160 105 115 140 165 120 130 155 180 Model C D 50 55 60 65 75 85 55 60 65 70 80 90 60 65 70 80 90 115 140 Model C R(D)QB20-15 -20 -25 -30 -40 -50 R(D)QB25-15 -20 -25 -30 -40 -50 R(D)QB32-20 -25 -30 -40 -50 -75 -100 R(D)QB40-20 -25 -30 -40 -50 -75 -100 R(D)QB50-30 -40 -50 -75 -100 R(D)QB63

() (4) 4 ,0.01mm 5-3 CEP1 A /B 90 11 12 11 10 10 ,A ,90,B ,B ,90,A , ,A B 6 6-1 ?

MY1 HT MY1 W MY1 W MY1CW (Cam follower guide type) 16, 20 25, 32, 40, 50, 63 MY2C MY2 H/HT MY3A MY3B MY3M B A B A Proper Auto Switch Mounting Position (mm) D-Z7/Z80 D-Y59/Y7P D-Y7W D-Y7BA D-M9V D-M9WV D-M9AV D-A9 D-Y69/Y7PV D-Y7WV D-M9 D-M9W D-M9A Bore size (mm) A B A B A B A B A B 16 20 25 32 40 50 63 74 86 70 90 94 106 90 110 102 118 102 118 97 123 97 123 132 148 132 148 127 153

Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) A93L 5 m Z (Example) F9NWZ In addition to the models in the above table, there are some other auto switches that are applicable.

Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) A93L 5 m Z (Example) F9NWZ In addition to the models in the above table, there are some other auto switches that are applicable.

to the D-B53/B54, D-C73(C)/C80C, D-A93(V), D-A73(C)/A80C, DA53/A54, D-Z73, and D-90/97/90A/93A only. 4) For reed auto switches M8 and M12 type with connector, please contact SMC. 5) The standard lead wire length of the trimmer auto switch is 3 m. 6) The standard lead wire length of the solid state auto switch with the timer except for the D-P3DW and D-M9A (V), water-resistant 2-color

115 140 55 60 65 70 75 80 85 90 95 120 145 M3 x 30 x 35 x 40 x 45 x 50 x 55 M3 x 30 x 35 x 40 x 45 x 50 x 55 M5 x 35 x 40 x 45 x 50 x 55 x 60 x 65 x 70 x 75 x 80 M5 x 40 x 45 x 50 x 55 x 60 x 65 x 70 x 75 x 80 x 85 M5 x 40 x 45 x 50 x 55 x 60 x 65 x 70 x 75 x 80 x 85 x 110 x 135 M5 x 45 x 50 x 55 x 60 x 65 x 70 x 75 x 80 x 85 x 90 x 115 x 140 M6 x 55 x 60 x 65 x 70 x 75 x 80 x 85 x 90 x

Bore size (mm) 12 16 20 25 32 40 Distance between guide rods GP 50 65 80 90 110 130 GP > 0.5 Calculation of load ratio to the theoretical output of cylinder = f / F Horizontal mounting: f = x W Inclined mounting: f = x Wcos + Wsin (Refer to the figure on the right.)

Lead wire length (m) Load voltage 5 (Z) Applicable load Auto switch model Electrical entry direction Wiring (Output) Special function Electrical entry Indicator light Type 0.5 (Nil) 1 (M) 3 (L) AC DC 12 V In-line A93 M9N M9B Reed auto switch 24 V 2-wire 100 V 12 V Relay, PLC Grommet Yes 3-wire (NPN) Solid state auto switch 24 V Relay, PLC Grommet Yes 12 V 2-wire Lead wire length symbols

Yes Applicable Auto Switch: 20, 25, 32 Lead wire length (m) Load voltage Auto switch model Indicator light Applicable load Type Electrical entry Wiring (Output) Electrical entry direction Special function 0.5 (Nil) 3 (L) 5 (Z) AC DC Perpendicular In-line A90 A90V No 100 V or less 5 V, 12 V IC circuit Relay PLC 2-wire Reed switch Reed switch Solid state switch Solid state switch 24 V A93

A /B 90 0.1mm/ 2-1. 2-2 F.G CE1-R** CE1 CEU5 OUT1OUT5 RS-232C OUT1OUT20(bank ) (31 ) 221 () B L F G D 0.5 L 3 Z 12 12mm 20 20mm 32 32mm 40 40mm 50 50mm 63 63mm 4063 N R H (mm) (mm) (mm) 25 50 75 100 125 150 175 200 250 300 400 500 12 20 32 40 50 63 222 A90 D-A90 M9N D-M9N M9NW D-M9NW A93 D-A93 M9P D-M9P M9PW D-M9PW A96 D-A96 M9B D-M9B M9BW D-M9BW A90V D-A90V M9NV D-M9NV

As a rule, it can be turned about 90 past the point at which tightening can be felt. Flat head watchmakers screw driver Auto switch 5 to 6 Switch mounting screw (M2.5 x 4l) (included) Auto Switch Specifications (1) Switches (switch rail) can be added to the standard type (without switch rail).

Auto Switch Proper Mounting Position for Stroke End Detection MY1CW 16, 20 MY1MW 16, 20 B A Reed switch D-A90(V), D-A93(V), D-A96(V) Solid state switch D-F9N(V), D-F9P(V), D-F9B(V) D-F9NW(V), D-F9PW(V), D-F9BW(V) Mounting position 20 16 20 16 20 Mounting position Mounting position 16 A 90 70 93 73 94 A A 74 B 110 90 107 87 106 B B 86 Operating range Note) 7.5 11 6.5 8.5 6.5 Operating range

Weight (g) CRBU2W10 CRBU2W15 CRBU2W20 CRBU2W30 90 CRBU2W40 90 Vane type Model (size) 90 270 180 90 270 180 180 270 180 270 180 90 270 Rotating angle Single vane Double vane 469 47.1 263 140 142 143 72 47.5 258 255 491 480 72 73 47 Body of rotary actuator Auto switch unit + 2 switches 30 50 60 46.5 30 Angle adjuster 30 90 150 203 47 90 100 90 100 90 90 100 90 100 100 Rotating angle 158 308

IC circuit 5 V, 12 V 3-wire (PNP) Relay, PLC 2-wire 12 V Grommet 5 V, 12 V 24 V 3-wire (NPN) 3-wire (PNP) IC circuit Diagnostic indication (2-color indication) 12 V 2-wire Lead wire length symbols: 0.5 mNil (Example) A93 3 mL (Example) A93L 5 mZ (Example) F9NWZ Since there are other applicable auto switches than listed, refer to page 8-10-22 for details.