Cooling Capacity: 040 (Cooling Capacity: 3800W/4200W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: J (Automatic Water Supply Function)

Cooling Capacity: 060 (Cooling Capacity: 4900/5900, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: J (Automatic Water Supply Function)

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 20 (3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz), Option: J (w/Automatic Fluid Fill Function)

Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: J (w/Automatic Fluid Fill Function)

Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter

Ambient temperature (C) Recommended circulating fluids 10 to 45 Tap water, ethylene glycol aqueous solution 15(wt)% -5 to 10 Ethylene glycol aqueous solution 15(wt)% -20 to -5 Ethylene glycol aqueous solution 40(wt)% Circulating fluid temperature(C) Recommended circulating fluids 10 to 35 Tap water, ethylene glycol aqueous solution 15(wt)% 5 to 10 Ethylene glycol aqueous solution 15(wt)%

capacity [kW] 8 8 6 6 4 4 2 2 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [oC] Circulating fluid temperature [oC] 50Hz 60Hz Fig. 8-5 Cooling capacity(HRS100-A-20/40/46-) 8.4.2 HRS150-A-20/40/46: Ambient temperature: 32 oC : Ambient temperature: 40oC : Ambient temperature: 45 oC 18 18 16 16 14 14 Cooling capacity [kW] Cooling capacity [kW] 12 12 10 10 8 8 6 6

Load weight Allowable moment E-MY2H/m3 E-MY2H/M3 E-MY2H/M1 E-MY2H/M2 60 50 60 50 60 50 60 50 40 40 30 30 30 30 q r w et 20 20 20 20 Moment (Nm) Moment (Nm) Moment (Nm) Moment (Nm) 10 10 10 10 MY2H25 MY2H25 MY2H25 MY2H25 5 5 5 5 4 4 MY2H16 4 4 3 3 3 3 MY2H16 MY2H16 2 2 2 2 MY2H16 0.2 1 1 1 100 200 300 400500 1000 1500 1 100 200 300400 500 1000 1500 100 200 300400500 1000 1500 100 200 300400500

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: T (High-pressure Pump)

Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: Rc, Option: B + J + M

Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: Rc, Option: B + M

Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: Rc, Option: M [Applicable to DI Water (Deionized Water) Piping]

Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: Rc, Option: M + T

Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: Rc, Option: High-pressure Pump

Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: High-pressure Pump

Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: Earth Leakage Breaker