SMC Corporation of America
Elite Part Number Search
Search Results "HRS100-W-40-AK"

grill of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, FAN CONTROLLER BOARD (HRS100

the grill of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, REAR FEFT PANEL FOR HRS100

the grill of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, REAR RIGHT PANEL FOR HRS100

of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, Temperature Sensor HRL100/300 HRS100

the grill of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, DC Power Supply for HRS100

FILTER FOR HRS100. OTHERS. HRS - NO SIZE RATING. 2.23666 lb. 21.

Cooling Capacity: 100 (10 kW), Cooling Method: A (Air-cooled), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)]

Cooling Capacity: 100 (10 kW), Cooling Method: A (Air-cooled), Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)]

Cooling Capacity: 100 (10 kW), Cooling Method: W (Water-cooled), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)]

Cooling Capacity: 100 (10 kW), Cooling Method: A (Air-cooled), Pipe Thread: F (G, w/Rc-G Conversion Fitting), Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)]

Cooling Capacity: 10 kW, Cooling Method: Air-cooled, Pipe Thread: NPT, w/Rc-NPT Conversion Fitting, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: -

Cooling Capacity: 10 kW, Cooling Method: Air-cooled, Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: -

Cooling Capacity: 10 kW, Cooling Method: Water-cooled, Pipe Thread: NPT, w/Rc-NPT Conversion Fitting, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: -

Cooling Capacity: 10 kW, Cooling Method: Air-cooled, Pipe Thread: G, w/Rc-G Conversion Fitting, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: -

Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance.  An angled supply port facilitates the supply of circulating fluid, even when units are stacked.  A large digital display provides a clear view of the current and set values.  The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter

Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance.  An angled supply port facilitates the supply of circulating fluid, even when units are stacked.  A large digital display provides a clear view of the current and set values.  The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter

Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance.  An angled supply port facilitates the supply of circulating fluid, even when units are stacked.  A large digital display provides a clear view of the current and set values.  The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter

9 @0 @1 @2 @3 @4 @5 Note Material PBT PBT PBT Brass Brass Brass Brass Brass Brass Brass No. q w e r t y u i o !0 !1 !2 !